368 research outputs found
The "Republic of Moldova" between transition, globalisation and European integration
The Republic of Moldova is situated in south-eastern Europe, between Romania (in the west) and Ukraine (in the north, east and south). Moldova’s population consisted of 4,4 million inhabitants1, on 33,7 thousand square kilometres and the distances between the most northern and the southern points is 350 kilometres and 150 kilometres from west to east. The combination of climate and soil conditions create high yelds of cereals, grapes, tobacco, fruit and vegetables
Azerbaijan, the door to orient between transition, globalisation and European integration
Now is near Baku and not so far to Italy the Azerbaijan. After three years, with exchanges between the University Sophia Antipolis of Nice, the University Pierre Mendes of Grenoble, the University of Genoa and the University Rassoulzadé of Baku, the Tempus Tacis project is closed
Correlated electron-hole plasma in organometal perovskites
Organic-inorganic perovskites are a class of solution-processed semiconductors holding promise for the realization of low-cost efficient solar cells and on-chip lasers. Despite the recent attention they have attracted, fundamental aspects of the photophysics underlying device operation still remain elusive. Here we use photoluminescence and transmission spectroscopy to show that photoexcitations give rise to a conducting plasma of unbound but Coulomb-correlated electron-hole pairs at all excitations of interest for light-energy conversion and stimulated optical amplification. The conductive nature of the photoexcited plasma has crucial consequences for perovskite-based devices: in solar cells, it ensures efficient charge separation and ambipolar transport while, concerning lasing, it provides a low threshold for light amplification and justifies a favourable outlook for the demonstration of an electrically driven laser. We find a significant trap density, whose cross-section for carrier capture is however low, yielding a minor impact on device performance
Response to Wirostko et al. Re: "Cross-Linked Hyaluronic Acid as Tear Film Substitute" by Posarelli et al. (J Ocul Pharmacol Ther 2019;35(7):381-387)
Response to Wirostko et al. Re: “Cross-Linked Hyaluronic Acid as Tear Film Substitute” by Posarelli et al. (J Ocul Pharmacol Ther 2019;35(7):381–387)." Journal of Ocular Pharmacology and Therapeutics, 36(4), pp. 206–20
Absorbable versus non-absorbable sutures for skin closure after carpal tunnel decompression surgery
BACKGROUND: Carpal tunnel syndrome is a common problem and surgical decompression of the carpal tunnel is the most effective treatment. After surgical decompression, the palmar skin may be closed using either absorbable or non-absorbable sutures. To date, there is conflicting evidence regarding the ideal suture material and this formed the rationale for our review. OBJECTIVES: To assess the effects of absorbable versus non-absorbable sutures for skin closure after elective carpal tunnel decompression surgery in adults on postoperative pain, hand function, scar satisfaction, wound inflammation and adverse events. SEARCH METHODS: We searched the following databases on 30 October 2017: the Cochrane Neuromuscular Specialised Register, CENTRAL, MEDLINE, and Embase. We searched two clinical trials registries on 30 October 2017. SELECTION CRITERIA: We considered all randomised or quasi-randomised controlled trials comparing absorbable and non-absorbable sutures for skin closure after any form of carpal tunnel decompression surgery in adults. DATA COLLECTION AND ANALYSIS: The unit of analysis was the hand rather than the patient. We performed meta-analysis of direct comparisons to generate standardised mean differences (SMDs) with 95% confidence intervals (CIs) in pain scores and risk ratios (RRs) with 95% CIs for dichotomous outcomes, such as wound inflammation. The primary outcome was postoperative pain. Secondary outcomes included hand function, scar satisfaction, scar inflammation and adverse events (complications). We assessed the quality of evidence for key outcomes using GRADE. MAIN RESULTS: We included five randomised trials (255 participants). The trials were all European (UK, Republic of Ireland, Denmark and the Netherlands). Where quoted, the mean age of participants was between 48 and 53 years. The trials measured outcomes between one and 12 weeks postoperatively.Meta-analysis of postoperative pain scores for absorbable versus non-absorbable sutures at 10 days following open carpal tunnel decompression (OCTD) produced a SMD of 0.03 (95% CI -0.43 to 0.48; 3 studies, number of participants (N) = 137; I2 = 43%); the SMD suggests little or no difference, but with a high degree of uncertainty because of very low-quality evidence. At 10 days following endoscopic carpal tunnel decompression (ECTD), the SMD for postoperative pain with use of absorbable versus non-absorbable sutures was -0.81 (95% CI -1.36 to -0.25; 1 study; N = 54); although the SMD is consistent with a large effect, the very low-quality evidence means the results are very uncertain. Only the OCTD studies provided pain data at 6 weeks, when the SMD was 0.06 (95% CI -0.72 to 0.84; 4 studies; N = 175; I2 = 84%), which indicates little or no evidence of difference, but with a high degree of uncertainty (very low-quality evidence). The RR for wound inflammation using absorbable versus non-absorbable sutures after OCTD was 2.28 (95% CI 0.24 to 21.91; N = 95; I2 = 90%) and after ECTD 0.93 (95% CI 0.06 to 14.09; 1 study, N = 54). Any difference in effect on wound inflammation is uncertain because the quality of evidence is very low. One study reported postoperative hand function but found no evidence of a difference between suture types at two weeks (mean difference (MD) -0.10, 95% CI -0.53 to 0.33, N = 36), with similar findings at six and 12 weeks. Only the ECTD trial reported scar satisfaction, with 25 out of 28 people reporting a 'nice' result in the absorbable-suture group, versus 18 out of 26 in the group who received non-absorbable sutures (RR 1.29, 95% CI 0.97 to 1.72, N = 54). These findings are also very uncertain as we judged the quality of the evidence to be very low. All studies were at high risk of bias for most domains. No trials reported adverse events. AUTHORS' CONCLUSIONS: It is uncertain whether absorbable sutures confer better, worse or equivalent outcomes compared to non-absorbable sutures following carpal tunnel decompression, because the quality of evidence is very low. Use of absorbable suture eliminates the need for suture removal, which could confer considerable savings to patients and healthcare providers alike. We need rigorously-performed, non-inferiority randomised trials with economic analyses to inform choice of suture
Ophthalmological emergencies and the SARSCoV-2 outbreak
Since the end of 2019, an outbreak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), originating in the Chinese city of Wuhan has spread rapidly worldwide causing thousands of deaths. Coronavirus disease (COVID-19) is supported by SARS-CoV-2 and represents the causative agent of a potentially fatal disease that is of great global public health concern. Italy has been the first European country recording an elevated number of infected forcing the Italian Government to call for total lockdown. The lockdown had the aim to limit the spread of infection through social distancing. The purpose of this study is to analyze how the pandemic has affected the patient’s accesses to the Ophthalmological Emergency Department of a tertiary referral center in central-northern Italy, during the lockdown period. The charts of all patients that came to the Emergency Department during the lockdown period (March 10 –May 4, 2020) have been retrospectively collected and compared with those in the same period of 2019 and the period from 15 January– 9 March 2020. A significant reduction of visits during the lockdown has been observed, compared with those of pre-lockdown period (reduction of 65.4%) and with those of the same period of 2019 (reduction of 74.3%). Particularly, during the lockdown, minor and not urgency visits decreased whereas the undeferrable urgency ones increased. These pieces of evidence could be explained by the fear of patients to be infected; but also revealed patients misuse of emergency services
What is the impact of intraoperative microscope-integrated oct in ophthalmic surgery? Relevant applications and outcomes. a systematic review
Background: Optical coherence tomography (OCT) has recently been introduced in the operating theatre. The aim of this review is to present the actual role of microscope-integrated optical coherence tomography (MI-OCT) in ophthalmology. Method: A total of 314 studies were identified, following a literature search adhering to the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. After full-text evaluation, 81 studies discussing MI-OCT applications in ophthalmology were included. Results: At present, three microscope-integrated optical coherence tomography systems are commercially available. MI-OCT can help anterior and posterior segment surgeons in the decision-making process, providing direct visualization of anatomic planes before and after surgical manoeuvres, assisting in complex cases, and detecting or confirming intraoperative complications. Applications range from corneal transplant to macular surgery, including cataract surgery, glaucoma surgery, paediatric examination, proliferative diabetic retinopathy surgery, and retinal detachment surgery. Conclusion: The use of MI-OCT in ophthalmic surgery is becoming increasingly prevalent and has been applied in almost all procedures. However, there are still limitations to be overcome and the technology involved remains difficult to access and use
- …