23,456 research outputs found
The Takagi problem on the disk and bidisk
We give a new proof on the disk that a Pick problem can be solved by a
rational function that is unimodular on the unit circle and for which the
number of poles inside the disk is no more than the number of non-positive
eigenvalues of the Pick matrix. We use this method to find rational solutions
to Pick problems on the bidisk
Isostaticity in two dimensional pile of rigid disks
We study the static structure of piles made of polydisperse disks in the
rigid limit with and without friction using molecular dynamic simulations for
various elasticities of the disks and pile preparation procedures. The
coordination numbers are calculated to examine the isostaticity of the pile
structure. For the frictionless pile, it is demonstrated that the coordination
number converges to 4 in the rigid limit, which implies that the structure of
rigid disk pile is isostatic. On the other hand, for the frictional case with
the infinite friction constant, the coordination number depends on the
preparation procedure of the pile, but we find that the structure becomes very
close to isostatic with the coordination number close to 3 in the rigid limit
when the pile is formed through the process that tends to make a pile of random
configuration.Comment: 3 pages, 3 figures, Submitted to J. Phys. Soc. Jp
Variable frequency microwave (VFM) processing facilities and application in processing thermoplastic matrix composites
Microwave processing of materials is a relatively new technology advancement alternative that provides new approaches for enhancing material properties as well as economic advantages through energy savings and accelerated product development. Factors that hinder the use of microwaves in materials processing are declining, so that prospect for the development of this technology seem to be very promising. The two mechanisms of orientation polarisation and interfacial space charge polarisation, together with dc conductivity, form the basis of high frequency heating. Clearly, advantages in utilising microwave technologies for processing materials include penetration radiation, controlled electric field distribution and selective and volumetric heating. However, the most commonly used facilities for microwave processing materials are of fixed frequency, e.g. 2.45 GHz. This paper presents a state-of-the-art review of microwave technologies, processing methods and industrial applications, using variable frequency microwave (VFM) facilities. This is a new alternative for microwave processing
Comparison of estimates of surface fluid motions of the earth's core various epochs
Method of determining velocity of surface fluid motions of earth core for various epoch
Cost Effective Capture of multiple IQ streams for Phase Arrays
This paper introduces a new and affordable method of realising 10 IQ Software Defined receivers, and how to synchronise them. We first discuss the need for multiple IQ and the available techniques. We then introduce the RTL-SDR and Matlab as a very low cost prototype implementation of 10 IQ streams. This leads to the design and manufacture of a PCB to distribute a single clock to multiple RTL-SDRs. The required modifications to the RTL-SDRs to receive the distributed clock and other modifications to improve the overall performance are presented. We then describe how to attain raw IQ data and synchronise the receivers. Finally, we prove all 10 can maintain a phase lock over a frame of 7 seconds
Growth of a plant tissue culture in the gravity-free state semiannual status report, 1 oct. 1963 - 31 mar. 1964
Zero gravity effect on regeneration and normal growth of tobacco stem segment
Validation of ICD-9-CM diagnosis codes for surgical site infection and noninfectious wound complications after mastectomy
BACKGROUNDFew studies have validated ICD-9-CM diagnosis codes for surgical site infection (SSI), and none have validated coding for noninfectious wound complications after mastectomy.OBJECTIVESTo determine the accuracy of International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) diagnosis codes in health insurer claims data to identify SSI and noninfectious wound complications, including hematoma, seroma, fat and tissue necrosis, and dehiscence, after mastectomy.METHODSWe reviewed medical records for 275 randomly selected women who were coded in the claims data for mastectomy with or without immediate breast reconstruction and had an ICD-9-CM diagnosis code for a wound complication within 180 days after surgery. We calculated the positive predictive value (PPV) to evaluate the accuracy of diagnosis codes in identifying specific wound complications and the PPV to determine the accuracy of coding for the breast surgical procedure.RESULTSThe PPV for SSI was 57.5%, or 68.9% if cellulitis-alone was considered an SSI, while the PPV for cellulitis was 82.2%. The PPVs of individual noninfectious wound complications ranged from 47.8% for fat necrosis to 94.9% for seroma and 96.6% for hematoma. The PPVs for mastectomy, implant, and autologous flap reconstruction were uniformly high (97.5%–99.2%).CONCLUSIONSOur results suggest that claims data can be used to compare rates of infectious and noninfectious wound complications after mastectomy across facilities, even though PPVs vary by specific type of postoperative complication. The accuracy of coding was highest for cellulitis, hematoma, and seroma, and a composite group of noninfectious complications (fat necrosis, tissue necrosis, or dehiscence).Infect Control Hosp Epidemiol 2017;38:334–339</jats:sec
- …