829 research outputs found

    The utility of troponin measurement to detect myocardial infarction: review of the current findings

    Get PDF
    Myocardial infarction (MI) is defined by the presence of myocardial necrosis in combination with clinical evidence of myocardial ischemia. Cardiac troponins are regulatory proteins within the myocardium that are released into the circulation when damage to the myocyte has occurred. Therefore, serum troponin is an exquisitely sensitive marker of myocardial injury and is necessary for establishing the diagnosis of MI. High-sensitivity troponin assays are improving the diagnostic accuracy and rapid detection of myocardial infarction. The early identification of MI is vital for the institution of anti-thrombotic therapy to limit myocardial damage and preserve cardiac function. Troponin has both diagnostic and prognostic significance in the setting of acute coronary syndrome (ACS). Increased troponin levels in the absence of ACS should prompt an evaluation for an alternative, non-thrombotic mechanism of troponin elevation and direct management at the underlying cause. This review describes the role of troponin in the evaluation of patients with suspected myocardial infarction

    Clinical Practice Guidelines for Recall and Maintenance of Patients with Tooth-Borne and Implant-Borne Dental Restorations

    Get PDF
    Purpose To provide guidelines for patient recall regimen, professional maintenance regimen, and at-home maintenance regimen for patients with tooth-borne and implant-borne removable and fixed restorations. Materials and Methods The American College of Prosthodontists (ACP) convened a scientific panel of experts appointed by the ACP, American Dental Association (ADA), Academy of General Dentistry (AGD), and American Dental Hygienists Association (ADHA) who critically evaluated and debated recently published findings from two systematic reviews on this topic. The major outcomes and consequences considered during formulation of the clinical practice guidelines (CPGs) were risk for failure of tooth- and implant-borne restorations. The panel conducted a round table discussion of the proposed guidelines, which were debated in detail. Feedback was used to supplement and refine the proposed guidelines, and consensus was attained. Results A set of CPGs was developed for tooth-borne restorations and implant-borne restorations. Each CPG comprised (1) patient recall, (2) professional maintenance, and (3) at-home maintenance. For tooth-borne restorations, the professional maintenance and at-home maintenance CPGs were subdivided for removable and fixed restorations. For implant-borne restorations, the professional maintenance CPGs were subdivided for removable and fixed restorations and further divided into biological maintenance and mechanical maintenance for each type of restoration. The at-home maintenance CPGs were subdivided for removable and fixed restorations. Conclusions The clinical practice guidelines presented in this document were initially developed using the two systematic reviews. Additional guidelines were developed using expert opinion and consensus, which included discussion of the best clinical practices, clinical feasibility, and risk-benefit ratio to the patient. To the authors’ knowledge, these are the first CPGs addressing patient recall regimen, professional maintenance regimen, and at-home maintenance regimen for patients with tooth-borne and implant-borne restorations. This document serves as a baseline with the expectation of future modifications when additional evidence becomes available

    A Systematic Review of Recall Regimen and Maintenance Regimen of Patients with Dental Restorations. Part 2: Implant-Borne Restorations

    Get PDF
    Purpose To evaluate the current scientific evidence on patient recall and maintenance of implant-supported restorations, to standardize patient care regimens and improve maintenance of oral health. An additional purpose was to examine areas of deficiency in the current scientific literature and provide recommendations for future studies. Materials and Methods An electronic search for articles in the English language literature from the past 10 years was performed independently by multiple investigators using a systematic search process. After application of predetermined inclusion and exclusion criteria, the final list of articles was reviewed to meet the objectives of this review. Results The initial electronic search resulted in 2816 titles. The systematic application of inclusion and exclusion criteria resulted in 14 articles that satisfied the study objectives. An additional 6 articles were added through a supplemental search process for a total of 20 studies. Of these, 11 were randomized controlled clinical trials, and 9 were observational studies. The majority of the studies (15 out of 20) were conducted in the past 5 years and most studies were conducted in Europe (15), followed by Asia (2), South America (1), the United States (1), and the Middle East (1). Results from the qualitative data on a combined 1088 patients indicated that outcome improvements in recall and maintenance regimen were related to (1) patient/treatment characteristic (type of prosthesis, type of prosthetic components, and type of restorative materials); (2) specific oral topical agents or oral hygiene aids (electric toothbrush, interdental brush, chlorhexidine, triclosan, water flossers) and (3) professional intervention (oral hygiene maintenance, and maintenance of the prosthesis). Conclusions There is minimal evidence related to recall regimens in patients with implant-borne removable and fixed restorations; however, a considerable body of evidence indicates that patients with implant-borne removable and fixed restorations require lifelong professional recall regimens to provide biological and mechanical maintenance, customized for each patient. Current evidence also demonstrates that the use of specific oral topical agents and oral hygiene aids can improve professional and at-home maintenance of implant-borne restorations. There is evidence to demonstrate differences in mechanical and biological maintenance needs due to differences in prosthetic materials and designs. Deficiencies in existing evidence compel the forethought of creating clinical practice guidelines for recall and maintenance of patients with implant-borne dental restorations

    Economic benefits from instream flow in a Colorado mountain stream

    Get PDF
    Submitted to Office of Water Research and Technology, U.S. Department of Interior.Bibliography: pages [131]-135.OWRT project no. A-035-COLO and OWRT project no. A-040-COLO

    Reduced appropriate implantable cardioverter-defibrillator therapy after cardiac resynchronization therapy-induced left ventricular function recovery: a meta-analysis and systematic review

    Get PDF
    Aims For patients undergoing cardiac resynchronization therapy (CRT) with implantable cardioverter-defibrillator (ICD; CRT-D), the effect of an improvement in left ventricular ejection fraction (LVEF) on appropriate ICD therapy may have significant implications regarding management at the time of ICD generator replacement. Methods and results We conducted a meta-analysis to determine the effect of LVEF recovery following CRT on the incidence of appropriate ICD therapy. A search of multiple electronic databases identified 709 reports, of which 6 retrospective cohort studies were included (n = 1740). In patients with post-CRT LVEF ≥35% (study n = 4), the pooled estimated rate of ICD therapy (5.5/100 person-years) was significantly lower than patients with post-CRT LVEF <35% [incidence rate difference (IRD): −6.5/100 person-years, 95% confidence interval (95% CI): −8.8 to −4.2, P < 0.001]. Similarly, patients with post-CRT LVEF ≥45% (study n = 4) demonstrated lower estimated rates of ICD therapy (2.3/100 person-years) compared with patients without such recovery (IRD: −5.8/100 person-years, 95% CI: −7.6 to −4.0, P < 0.001). Restricting analysis to studies discounting ICD therapies during LVEF recovery (study n = 3), patients with LVEF recovery (≥35 or ≥45%) had significantly lower rates of ICD therapy compared with patients without such recovery (P for both <0.001). Patients with primary prevention indication for ICD, regardless of LVEF recovery definition, had very low rates of ICD therapy (0.4 to 0.8/100-person years). Conclusion Recovery of LVEF post-CRT is associated with significantly reduced appropriate ICD therapy. Patients with improvement of LVEF ≥45% and those with primary prevention indication for ICD appear to be at lowest ris

    Abnormal ECG Findings in Athletes: Clinical Evaluation and Considerations.

    Get PDF
    PURPOSE OF REVIEW: Pre-participation cardiovascular evaluation with electrocardiography is normal practice for most sporting bodies. Awareness about sudden cardiac death in athletes and recognizing how screening can help identify vulnerable athletes have empowered different sporting disciplines to invest in the wellbeing of their athletes. RECENT FINDINGS: Discerning physiological electrical alterations due to athletic training from those representing cardiac pathology may be challenging. The mode of investigation of affected athletes is dependent on the electrical anomaly and the disease(s) in question. This review will highlight specific pathological ECG patterns that warrant assessment and surveillance, together with an in-depth review of the recommended algorithm for evaluation
    corecore