10,281 research outputs found
Magnetic spectrum of the two-dimensional antiferromagnet La2CoO4 studied by inelastic neutron scattering
We report measurements of the magnetic excitation spectrum of the layered
antiferromagnet La2CoO4 by time-of-flight neutron inelastic scattering. In the
energy range probed in our experiments (0-250 meV) the magnetic spectrum
consists of spin-wave modes with strong in-plane dispersion extending up to 60
meV, and a nearly dispersionless peak at 190 meV. The spin-wave modes exhibit a
small (~1 meV) dispersion along the magnetic zone boundary. We show that the
magnetic spectrum can be described very well by a model of a Heisenberg
antiferromagnet that includes the full spin and orbital degrees of freedom of
Co2+ in an axially-distorted crystal field. The collective magnetic dynamics
are found to be controlled by dominant nearest-neighbour exchange interactions,
strong XY-like single-ion anisotropy and a substantial unquenched orbital
angular momentum.Comment: 8 pages, 7 figure
Facility for fast neutron irradiation tests of electronics at the ISIS spallation neutron source
The VESUVIO beam line at the ISIS spallation neutron source was set up for neutron irradiation tests in the neutron energy range above 10 MeV. The neutron flux and energy spectrum were shown, in benchmark activation measurements, to provide a neutron spectrum similar to the ambient one at sea level, but with an enhancement in intensity of a factor of 107. Such conditions are suitable for accelerated testing of electronic components, as was demonstrated here by measurements of soft error rates in recent technology field programable gate arrays
The accuracy of interpretation of emergency abdominal CT in adult patients who present with non-traumatic abdominal pain: results of a UK national audit.
: To evaluate major/minor discrepancy rates for provisional (initial) and addendum (supplementary senior review) emergency computed tomography (CT) reports in patients presenting with non-traumatic abdominal pain. : Ethical approval for this type of study is not required in the UK. All radiology departments with an approved lead for audit registered with the Royal College of Radiologists were invited to participate in this retrospective audit. The first 50 consecutive patients (25 surgical, 25 non-surgical) who underwent emergency abdominal CT for non-traumatic abdominal pain in 2013 were included. Statistical analyses were performed to identify organisational and report/patient-related variables that might be associated with major discrepancy. : One hundred and nine (58%) of 188 departments supplied data to the study with a total of 4,931 patients (2,568 surgical, 2,363 non-surgical). The audit standard for provisional report major discrepancy was achieved for registrars (target <10%, achieved 4.6%), for on-site consultants (target <5%, achieved 3.1%) and consultant addendum (target <5%, achieved 2.9%). Off-site reporters failed to meet the standard target (<5%, achieved 8.7% overall and 12.7% in surgical patients). The standard for patients coming to harm was not met in the surgical group (target <1%, achieved 1.5%) and was narrowly missed overall (target <1%, achieved 1%). : This study should be used to provide impetus to improve aspects of out-of-hours CT reporting. Clear benefits of CT interpretation/review by on-site and more senior (consultant) radiologists have been demonstrated.<br/
C/C ratio in planetary nebulae from the IUE archives
We investigated the abundance ratio of C/C in planetary nebulae
by examining emission lines arising from \ion{C}{3} 2s2p ^3P_{2,1,0} \to 2s^2
^1S_0. Spectra were retrieved from the International Ultraviolet Explorer
archives, and multiple spectra of the same object were coadded to achieve
improved signal-to-noise. The C hyperfine structure line at 1909.6 \AA
was detected in NGC 2440. The C/C ratio was found to be
1.2. In all other objects, we provide an upper limit for the flux
of the 1910 \AA line. For 23 of these sources, a lower limit for the
C/C ratio was established. The impact on our current
understanding of stellar evolution is discussed.
The resulting high signal-to-noise \ion{C}{3} spectrum helps constrain the
atomic physics of the line formation process. Some objects have the measured
1907/1909 flux ratio outside the low-electron density theoretical limit for
C. A mixture of C with C helps to close the gap somewhat.
Nevertheless, some observed 1907/1909 flux ratios still appear too high to
conform to the presently predicted limits. It is shown that this limit, as well
as the 1910/1909 flux ratio, are predominantly influenced by using the standard
partitioning among the collision strengths for the multiplet --
according to the statistical weights. A detailed calculation for the fine
structure collision strengths between these individual levels would be
valuable.Comment: ApJ accepted: 19 pages, 3 Figures, 2 Table
Mesoscopic Phase Coherence in a Quantum Spin Fluid
Mesoscopic quantum phase coherence is important because it improves the
prospects for handling quantum degrees of freedom in technology. Here we show
that the development of such coherence can be monitored using magnetic neutron
scattering from a one-dimensional spin chain Y2BaNiO5, a quantum spin fluid
where no classical, static magnetic order is present. In the cleanest samples,
the quantum coherence length is 20 nm, almost an order of magnitude larger than
the classical antiferromagnetic correlation length of 3 nm. We also demonstrate
that the coherence length can be modified by static and thermally activated
defects in a quantitatively predictable manner
Is keV ion induced pattern formation on Si(001) caused by metal impurities?
We present ion beam erosion experiments performed in ultra high vacuum using
a differentially pumped ion source and taking care that the ion beam hits the
Si(001) sample only. Under these conditions no ion beam patterns form on Si for
angles below 45 degrees with respect to the global surface normal using 2 keV
Kr ions and fluences of 2 x 10^22 ions/m^2. In fact, the ion beam induces a
smoothening of preformed patterns. Simultaneous sputter deposition of stainless
steel in this angular range creates a variety of patterns, similar to those
previously ascribed to clean ion beam induced destabilization of the surface
profile. Only for grazing incidence with incident angles between 60 degrees and
83 degrees pronounced ion beam patterns form. It appears that the angular
dependent stability of Si(001) against pattern formation under clean ion beam
erosion conditions is related to the angular dependence of the sputtering
yield, and not primarily to a curvature dependent yield as invoked frequently
in continuum theory models.Comment: 15 pages, 7 figures. This is an author-created, un-copyedited version
of an article published in Nanotechnology. IOP Publishing Ltd is not
responsible for any errors or omissions in this version of the manuscript or
any version derived from i
Disordered systems on various time scales: a-Si3B3N7 and homogeneous sintering
Modeling of materials systems for long times commonly requires the use of
separation of time scale methods. We discuss this general approach and present
two example systems, a-Si3B3N7 and the generation of homogeneous sinters.Comment: 22 pages, 7 figure
Diamond detector for high rate monitors of fast neutrons beams
A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t0. Fast acquisition is needed since the peak count rate is very high (~800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range Edep = 1.5-7 MeV ascribed to neutron elastic scattering on 12C; iii) large pulse amplitude neutron events with En < 7 MeV ascribed to 12C(n,α)9Be and 12C(n,n')3α
- …