622 research outputs found

    THE EMINENCE OF AMERICAN PSYCHOLOGISTS

    Get PDF

    Barriers to the use of a diagnostic oral microbiology laboratory by general dental practitioners

    Get PDF
    OBJECTIVE: To identify barriers on the use of diagnostic microbiology facilities in general dental practice. DESIGN: A cross-sectional survey using a postal questionnaire. SETTING: Primary/secondary care interface between the diagnostic oral microbiology laboratory, University of Glasgow Dental Hospital and School, Glasgow and dental practitioners within the surrounding health boards, 1998. SUBJECTS: All GDPs (797) within Argyll and Clyde, Ayrshire and Arran, Lanarkshire and Greater Glasgow Health Boards. MAIN OUTCOME MEASURES: The responses were expressed as both absolute and relative frequencies. RESULTS: Responses were received from 430 (55%). The most frequent reason for failure to use the service was lack of information, with more than half of the respondents claiming to be unaware of the facility. Lack of request forms and sampling equipment were also viewed as barriers to using the service. CONCLUSIONS: The laboratory is failing to successfully communicate its role in addressing the growing burden of antibiotic resistance in the community and must be more proactive in encouraging appropriate use and increasing accessibility of the service to GDPs

    Staphylococcus aureus in the oral cavity: a three-year retrospective analysis of clinical laboratory data

    Get PDF
    OBJECTIVE: A retrospective analysis of laboratory data to investigate the isolation of Staphylococcus aureus from the oral cavity and facial area in specimens submitted to a regional diagnostic oral microbiology laboratory. METHODS: A hand search of laboratory records for a three-year period (1998-2000) was performed for specimens submitted to the regional diagnostic oral microbiology laboratory based at Glasgow Dental Hospital and School. Data were collected from forms where S. aureus was isolated. These data included demographics, referral source, specimen type, methicillin susceptibility and clinical details. RESULTS: For the period 1998-2000, there were 5,005 specimens submitted to the laboratory. S. aureus was isolated from 1,017 specimens, of which 967 (95%) were sensitive to methicillin (MSSA) and 50 (5%) were resistant to methicillin (MRSA). The 1,017 specimens were provided from 615 patients. MRSA was isolated from 37 (6%) of patients. There was an increasing incidence of S. aureus with age, particularly in the greater than 70 years age group. The most common specimen from which MSSA was isolated was an oral rinse (38%) whilst for MRSA isolates this was a tongue swab (28%). The clinical condition most commonly reported for MSSA isolates was angular cheilitis (22%). Erythema, swelling, pain or burning of the oral mucosa was the clinical condition most commonly reported for MRSA isolates (16%). Patients from whom the MSSA isolates were recovered were most commonly (55%) seen in the oral medicine clinic at the dental hospital, whilst patients with MRSA were more commonly seen in primary care settings such as nursing homes, hospices and general dental practice (51%). CONCLUSION: In line with more recent surveys, this retrospective study suggests that S. aureus may be a more frequent isolate from the oral cavity than hitherto suspected. A small proportion of the S. aureus isolates were MRSA. There were insufficient data available to determine whether the S. aureus isolates were colonising or infecting the oral cavity. However, the role of S. aureus in several diseases of the oral mucosa merits further investigation

    A study of blood contamination of Siqveland matrix bands

    Get PDF
    AIMS To use a sensitive forensic test to measure blood contamination of used Siqveland matrix bands following routine cleaning and sterilisation procedures in general dental practice. MATERIALS AND METHODS: Sixteen general dental practices in the West of Scotland participated. Details of instrument cleaning procedures were recorded for each practice. A total of 133 Siqveland matrix bands were recovered following cleaning and sterilisation and were examined for residual blood contamination by the Kastle-Meyer test, a well-recognised forensic technique. RESULTS: Ultrasonic baths were used for the cleaning of 62 (47%) bands and retainers and the remainder (53%) were hand scrubbed prior to autoclaving. Overall, 21% of the matrix bands and 19% of the retainers gave a positive Kastle-Meyer test, indicative of residual blood contamination, following cleaning and sterilisation. In relation to cleaning method, 34% of hand-scrubbed bands and 32% of hand-scrubbed retainers were positive for residual blood by the Kastle-Meyer test compared with 6% and 3% respectively of ultrasonically cleaned bands and retainers (P less than 0.001). CONCLUSIONS: If Siqveland matrix bands are re-processed in the assembled state, then adequate pre-sterilisation cleaning cannot be achieved reliably. Ultrasonic baths are significantly more effective than hand cleaning for these items of equipment

    Dental treatment and risk of variant CJD - a case control study

    Get PDF
    Abstract Objective: Knowledge of risk factors for variant CJD (vCJD) remains limited, but transmission of prion proteins via re-useable medical devices, including dental instruments, or enhanced susceptibility following trauma to the oral cavity is a concern. This study aimed to identify whether previous dental treatment is a risk factor for development of vCJD. Design: Case control study Methods: Risk factor questionnaires completed by interview with relatives of 130 vCJD patients and with relatives of 66 community and 53 hospital controls were examined by a dental surgeon. Responses regarding dental treatments were analysed. Results: We did not find a statistically significant excess of risk of vCJD associated with dental treatments with the exception of extractions in an unmatched analysis of vCJD cases with community controls (p=0.02). However, this result may be explained by multiple testing. Conclusions: This is the first published study to date to examine potential links between vCJD and dental treatment. There was no convincing evidence found of an increased risk of variant CJD associated with reported dental treatment. However, the power of the study is restricted by the number of vCJD cases to date and does not preclude the possibility that some cases have resulted from secondary transmission via dental procedures. Due to the limitations of the data available, more detailed analyses of dental records are required to fully exclude the possibility of transmission via dental treatment

    Cross infection control measures and the treatment of patients at risk of Creutzfeldt Jakob disease in UK general dental practice

    Get PDF
    AIMS: To determine the suitability of key infection control measures currently employed in UK dental practice for delivery of dental care to patients at risk of prion diseases. MATERIALS AND METHODS: Subjects: Five hundred dental surgeons currently registered with the General Dental Council of the UK. Data collection: Structured postal questionnaire. Analysis: Frequencies, cross-tabulations and chi-squared analysis. RESULTS: The valid response rate to the questionnaire was 69%. 33% of practices had no policy on general disinfection and sterilisation procedures. Only 10 of the 327 responding practices (3%) possessed a vacuum autoclave. 49% of dentists reported using the BDA medical history form but less than 25% asked the specific questions recommended by the BDA to identify patients at risk of iatrogenic or familial CJD. However, 63% of practitioners would refer such patients, if identified, to a secondary care facility. Of the 107 practitioners who were prepared to provide dental treatment, 75 (70%) would do so using routine infection control procedures. CONCLUSIONS: Most of the dental practices surveyed were not actively seeking to identify patients at risk of prion diseases. In many cases, recommended procedures for providing safe dental care for such patients were not in place

    Screening for left ventricular hypertrophy in patients with type 2 diabetes mellitus in the community

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Left ventricular hypertrophy (LVH) is a strong predictor of cardiovascular disease and is common among patients with type 2 diabetes. However, no systematic screening for LVH is currently recommended for patients with type 2 diabetes. The purpose of this study was to determine whether NT-proBNP was superior to 12-lead electrocardiography (ECG) for detection of LVH in patients with type 2 diabetes.</p> <p>Methods</p> <p>Prospective cross-sectional study comparing diagnostic accuracy of ECG and NT-proBNP for the detection of LVH among patients with type 2 diabetes. Inclusion criteria included having been diagnosed for > 5 years and/or on treatment for type 2 diabetes; patients with Stage 3/4 chronic kidney disease and known cardiovascular disease were excluded. ECG LVH was defined as either the Sokolow-Lyon or Cornell voltage criteria. NT-proBNP level was measured using the Roche Diagnostics Elecsys assay. Left ventricular mass was assessed from echocardiography. Receiver operating characteristic curve analysis was carried out and area under the curve (AUC) was calculated.</p> <p>Results</p> <p>294 patients with type 2 diabetes were recruited, mean age 58 (SD 11) years, BP 134/81 ± 18/11 mmHg, HbA<sub>1c </sub>7.3 ± 1.5%. LVH was present in 164 patients (56%). In a logistic regression model age, gender, BMI and a history of hypertension were important determinants of LVH (p < 0.05). Only 5 patients with LVH were detected by either ECG voltage criteria. The AUC for NT-proBNP in detecting LVH was 0.68.</p> <p>Conclusions</p> <p>LVH was highly prevalent in asymptomatic patients with type 2 diabetes. ECG was an inadequate test to identify LVH and while NT-proBNP was superior to ECG it remained unsuitable for detecting LVH. Thus, there remains a need for a screening tool to detect LVH in primary care patients with type 2 diabetes to enhance risk stratification and management.</p

    Assessing the efficacy and cost of detergents used in a primary care automated washer disinfector

    Get PDF
    Background: Cleaning of re-usable medical devices is a critical control point in the decontamination cycle, although defined end-points of the process are controversial. Objective: Investigate cleaning efficacy and cost of different detergent classes in an automated washer disinfector (AWD) designed for dental practice. Methods: Loads comprised test soiled dental hand instruments in cassettes and extraction forceps. Residual protein assayed using the International standard method (ISO 15883-5:2005) 1% SDS elution with ortho-phthalaldehyde (OPA) or GBox technology (on instrument OPA analysis). Short (60 minutes) and long (97 minutes) AWD cycles were used with four different classes of detergents, tap water and reverse osmosis water. Results: SDS elution analysis (N = 612 instruments) demonstrated four detergents with both wash cycles achieved equivalent cleanliness levels and below a threshold of 200 μg protein/instrument. GBox methodology (N = 575) using UK Department of Health threshold of 5 μg/instrument side demonstrated that tap water performed with the greatest efficacy for all types of instruments and cycle types. Conclusions: Using International standard methodology, different detergent classes had equivalence in cleaning efficacy. Cheaper detergents used in this study performed with similar efficacy to more expensive solutions. Findings emphasise the importance of validating the detergent (type and concentration) for each AWD

    Technology-assisted stroke rehabilitation in Mexico: a pilot randomized trial comparing traditional therapy to circuit training in a Robot/technology-assisted therapy gym

    Get PDF
    Background Stroke rehabilitation in low- and middle-income countries, such as Mexico, is often hampered by lack of clinical resources and funding. To provide a cost-effective solution for comprehensive post-stroke rehabilitation that can alleviate the need for one-on-one physical or occupational therapy, in lower and upper extremities, we proposed and implemented a technology-assisted rehabilitation gymnasium in Chihuahua, Mexico. The Gymnasium for Robotic Rehabilitation (Robot Gym) consisted of low- and high-tech systems for upper and lower limb rehabilitation. Our hypothesis is that the Robot Gym can provide a cost- and labor-efficient alternative for post-stroke rehabilitation, while being more or as effective as traditional physical and occupational therapy approaches. Methods A typical group of stroke patients was randomly allocated to an intervention (n = 10) or a control group (n = 10). The intervention group received rehabilitation using the devices in the Robot Gym, whereas the control group (n = 10) received time-matched standard care. All of the study subjects were subjected to 24 two-hour therapy sessions over a period of 6 to 8 weeks. Several clinical assessments tests for upper and lower extremities were used to evaluate motor function pre- and post-intervention. A cost analysis was done to compare the cost effectiveness for both therapies. Results No significant differences were observed when comparing the results of the pre-intervention Mini-mental, Brunnstrom Test, and Geriatric Depression Scale Test, showing that both groups were functionally similar prior to the intervention. Although, both training groups were functionally equivalent, they had a significant age difference. The results of all of the upper extremity tests showed an improvement in function in both groups with no statistically significant differences between the groups. The Fugl-Meyer and the 10 Meters Walk lower extremity tests showed greater improvement in the intervention group compared to the control group. On the Time Up and Go Test, no statistically significant differences were observed pre- and post-intervention when comparing the control and the intervention groups. For the 6 Minute Walk Test, both groups presented a statistically significant difference pre- and post-intervention, showing progress in their performance. The robot gym therapy was more cost-effective than the traditional one-to-one therapy used during this study in that it enabled therapist to train up to 1.5 to 6 times more patients for the approximately same cost in the long term. Conclusions The results of this study showed that the patients that received therapy using the Robot Gym had enhanced functionality in the upper extremity tests similar to patients in the control group. In the lower extremity tests, the intervention patients showed more improvement than those subjected to traditional therapy. These results support that the Robot Gym can be as effective as traditional therapy for stroke patients, presenting a more cost- and labor-efficient option for countries with scarce clinical resources and funding. Trial registration ISRCTN98578807
    • …
    corecore