15 research outputs found

    Adherence of hip and knee arthroplasty studies to RSA standardization guidelines

    Get PDF
    Peer reviewe

    Reversible, non-plaque-induced loss of osseointegration of successfully loaded dental implants

    No full text
    Objectives: Excess loading has been often cited as a reason for the failure of dental implants or bone loss post-osseointegration. The available data from animal studies have failed to show a clear role for excessive loading in the loss of osseointegration. The present case documentations aimed at providing a deeper insight into the medium- to long-term influence of occlusal loading on osseointegrated implants, and describe the clinical manifestations of such pathology. Material and methods: Two cases of loss of osseointegration are documented with single implants in the posterior maxilla. Implant mobility was in both cases the first and only sign of pathology, with the absence of plaque-induced inflammation and marginal bone loss. Results: Re-osseointegration of the implants was achieved after the removal of the prosthetic reconstruction. Conclusions: The two cases reported that the loss of osseointegration in the absence of plaque-induced peri-implant inflammation is possible, although the clinical manifestations were very different to these of peri-implantitis. Once the occlusal loading was withdrawn, re-osseointegration was clinically confirmed in a period of 6-8 months. © 2012 John Wiley & Sons A/S.link_to_subscribed_fulltex

    Reversible, Non-plaque-induced loss of osseointegration of successfully loaded dental implants

    No full text
    Objectives: Excess loading has been often cited as a reason for the failure of dental implants or bone loss post-osseointegration. The available data from animal studies have failed to show a clear role for excessive loading in the loss of osseointegration. The present case documentations aimed at providing a deeper insight into the medium- to long-term influence of occlusal loading on osseointegrated implants, and describe the clinical manifestations of such pathology. Material and methods: Two cases of loss of osseointegration are documented with single implants in the posterior maxilla. Implant mobility was in both cases the first and only sign of pathology, with the absence of plaque-induced inflammation and marginal bone loss. Results: Re-osseointegration of the implants was achieved after the removal of the prosthetic reconstruction. Conclusions: The two cases reported that the loss of osseointegration in the absence of plaque-induced peri-implant inflammation is possible, although the clinical manifestations were very different to these of peri-implantitis. Once the occlusal loading was withdrawn, re-osseointegration was clinically confirmed in a period of 6-8 months. © 2012 John Wiley & Sons A/S

    A finite element analysis of tilted versus nontilted implant configurations in the edentulous maxilla.

    No full text
    The aim of this study was to evaluate stress patterns at the bone-implant interface of tilted versus nontilted implant configurations in edentulous maxillae using finite element models of two tilted and one nontilted configuration. Analysis predicted the maximum absolute value of principal compressive stress near the cervical area of the distal implant for all models. The tilted configurations showed a lower absolute value of compressive stress compared with the nontilted, indicating a possible biomechanical advantage in reducing stresses at the bone-implant interface

    Sir George and Lady Fuller holding a bouquet of flowers onboard a ship, New South Wales, ca. 1927, 1 [picture].

    No full text
    Title devised from accompanying information where available.; Part of the: Fairfax archive of glass plate negatives.; Fairfax number: 4589.; Also available online at: http://nla.gov.au/nla.pic-vn6247331; Acquired from Fairfax Media, 2012

    Comparison of Tilted and Nontilted Implant-Supported Prosthetic Designs for the Restoration of the Edentulous Mandible: A Biomechanical Study

    No full text
    Purpose: The purpose of the study was to evaluate, using finite element analysis, the stress patterns induced in cortical bone by three distinct implant-supported prosthetic designs. Materials and Methods: The first two models consisted of a prosthesis supported by four implants, the distal two of which were tilted, with different cantilever lengths (5 mm and 15 mm). The third design consisted of a prosthesis supported by five conventionally placed implants and a 15-mm cantilever. Results: In the tilted model with 5-mm cantilever and in the nontilted model, the maximum value of compressive stress (-18 Mpa) was found near the cervical area of the distal implant. Higher values for compressive stress were predicted near the cervical area of the distal implant in the tilted model with a 15-mm cantilever, as compared to the tilted model with the 5-mm cantilever. For the tilted model with the 5-mm cantilever, peak values of tensile stress were predicted near the cervical area of both the distal (1.25 Mpa) and the mesial implants (2.5 Mpa). For the nontilted model, the peak value was found near the cervical area of the in-between implant (5 Mpa). For the tilted model with 15-mm cantilever, tensile stress values were higher than in the tilted model with 5-mm cantilever. Conclusions: No significant difference in stress patterns between the tilted 5-mm and the nontilted 15-mm configuration was predicted. The tilted configuration with a 15-mm cantilever was found to induce higher stress values than the tilted configuration with a 5-mm cantilever
    corecore