87,317 research outputs found

    Computer program for stress, vibration, and buckling characteristics of general shells of revolution

    Get PDF
    Structures Research Associates (SRA) system of programs is composed of six compatible computer programs for structural analyses of axisymmetric shell structures. Theories and methods upon which these programs are based are presented in documentation. They apply to a common structural model but analyze different modes of structural response

    Feasibility study of shell buckling analysis using the modified structure method

    Get PDF
    The modified structure method, which is based on Koiter's theory of imperfections, was used to calculate approximate buckling loads of several shells of revolution. The method does not appear to be practical for shells because, in many cases, the prebuckling nonlinearity may be too large to be treated accurately as a small imperfection

    New Relations for Excited Baryons in Large N_c QCD

    Full text link
    We show that excited baryons in large N_c QCD form multiplets, within which masses are first split at O(1/N_c). The dominant couplings of resonances to various mesons are highly constrained: The N(1535) decays at leading 1/N_c order exclusively to eta-N rather than pi-N, and vice versa for the N(1650). This multiplet structure is reproduced by a simple large N_c quark model, well studied in the literature, that describes resonances as single-quark excitations.Comment: 4 pages, no figures, ReVTeX 4. Includes new discussion of previous work on excited baryon tower

    Low Frequency VLA Observations of Abell 754: Evidence for a Cluster Radio Halo and Possible Radio Relics

    Get PDF
    We present 74 MHz and 330 MHz VLA observations of Abell 754. Diffuse, halo-like emission is detected from the center of the cluster at both frequencies. At 330 MHz the resolution of 90'' distinguishes this extended emission from previously known point sources. In addition to the halo and at a much lower level, outlying steep-spectrum emission regions straddle the cluster center and are seen only at 74 MHz. The location, morphology and spectrum of this emission are all highly suggestive of at least one, and possibly two cluster radio relics. Easily obtained higher resolution, higher sensitivity VLA observations at both frequencies are required to confirm the extended nature of the halo-like emission and the 74 MHz relic detections. However, since there is prior evidence that this cluster is or has recently been in the process of a major merger event, the possible discovery of relics in this system is of great interest in light of recent observational and theoretical evidence in favor of a merger-relic connection. We discuss the possible role the merger shock waves, which are seen in the X-ray emission, may have played in the formation of the halo and radio relics in A754.Comment: 15 pages including 4 figures. Accepted for publication by Ap

    Quantitative detection of atropine-delayed gastric emptying in the horse by the <sup>13</sup>C-octanoic acid breath test

    Get PDF
    The &lt;sup&gt;13&lt;/sup&gt;C-octanoic acid breath test has been correlated significantly to radioscintigraphy for measurement of gastric emptying indices in healthy horses. The objective of this study was to investigate the validity of the test for measurement of equine delayed gastric emptying, prior to its potential clinical application for this purpose. A model of atropine- induced gastroparesis was used. Gastric emptying rate was measured twice in 8 horses using concurrent radioscintigraphy and/or breath test after treatment i.v. with either atropine (0.035 mg/kg bwt) or saline in randomised order. Analysis of both data sets demonstrated that the atropine treatment had caused a significant delay in gastric emptying rate. Paired breath test data showed an atropine-induced delay in gastric half-emptying time t(1/2)), with no overlap in the 99% Cl range (P&#60;0.001). Significant correlations were found between scintigraphy and &lt;sup&gt;13&lt;/sup&gt;C-octanoic acid breath test for calculation of both t(1/2) (P&#60;0.01) and lag phase duration (P&#60;0.05) in the atropine-delayed emptying results. The mean (s.d.) bias in breath test t(1/2) when compared with scintigraphy was 1.78 (0.58) h. The results demonstrated that the &lt;sup&gt;13&lt;/sup&gt;C-octanoic acid breath test was an effective diagnostic modality for the measurement of equine delayed gastric emptying. The technique offers advantages to existing methods for clinical investigation, as it is noninvasive, not radioactive, quantitative and requires minimal equipment or training to perform
    • …
    corecore