483 research outputs found

    The Effect of Workplace Stretching Exercise on Reducing Musculoskeletal Complaints in Ndao Ikat Weaving Workers in Rote Ndao District

    Get PDF
    Musculoskeletal complaints in Ndao weaving workers are a problem of muscle disorders for weavers. As a result of this process is a long time and repeatedly will cause musculoskeletal complaints. Workplace Stretching Exercise is designed with the principle of muscle stretching, which is an attempt to extend muscle rest or relaxation. This activity will improve blood circulation so that it helps relax nervous tension and train muscles to be stronger so they don't get tired easily while working. This study aimed to analyze the effect of workplace stretching exercises on the reduction of musculoskeletal complaints in Ndao weaving workers in Rote Ndao Regency. This is a quantitative research with a pre-experimental design type one-group pretest-posttest design method. The population in this study were active weavers in Ikat Ndao weaving, Lobalain District as many as 40 weavers. The selected research sample has met the eligibility criteria for as many as 18 active weavers. The type of analysis test used is the paired sample t-test. The results showed that there was a difference in the level of musculoskeletal complaints before the intervention was in the moderate complaint category with a percentage of 77.8% and after the WSE intervention, the complaints decreased to the low complaint category with a percentage of 66.7% with a significant decrease in value of 19.39%. The results of the analysis show that there is an effect of Workplace Stretching Exercise on the reduction of musculoskeletal complaints in Ndao tie weaving workers, where there is a large difference in value (p = 0.007 ) ≤ (0.05), so it is expected that Ndao tie weaving workers will carry out Workplace Stretching Exercise activities every day in between weaving activities to reduce musculoskeletal complaints

    Ablation of Left Atrial Tachycardia following Catheter Ablation of Atrial Fibrillation: 12-Month Success Rates

    Get PDF
    The treatment of atrial tachycardia following catheter ablation of atrial fibrillation is often challenging. Electrophysiological studies using high-resolution 3D mapping systems have contributed significantly to their understanding, and new ablation approaches have shown high rates of acute terminations with low recurrences for the clinical AT. However, patient populations are very heterogeneous, and long-term data of the freedom from any atrial tachycardia or any arrhythmia are still sparse. To evaluate long-term success, a unified patient population and predefined ablation strategies are preferred. In this study, we present 12-month success and mean 30 month follow-up data of catheter ablation of left atrial tachycardia. All 35 patients had a history of pulmonary vein isolation (PVI), 71% of which had a previous substrate modification. A total of 54 ATs, with a mean cycle length 297 ± 86 ms, 31 macro-reentries, and 4 localized reentries, were targeted. The ablation strategy to be used was given by the study protocol, depending on the type of reentry and the number of critical isthmuses. All available ablation strategies were included: standard (anatomical) lines, individual lines, critical isthmuses, and focal ablation. All ATs were terminated by ablation. A total of 91% terminated upon the first ablation strategy. Freedom from any AT after 12 months was 82%, and from any arrhythmia, it was 77%. The multi-procedure success after 30 months was 65% for any AT and 55% for any arrhythmia. In conclusion, individual ablation strategies based on the reentry mechanism and the number of critical isthmuses seems promising and demonstrates a high long-term clinical success. Tachycardia comprising a single critical isthmus can be ablated by critical isthmus ablation only. These patients present with the highest 12-month and long-term success rates

    ECG-Based Detection of Early Myocardial Ischemia in a Computational Model: Impact of Additional Electrodes, Optimal Placement, and a New Feature for ST Deviation

    Get PDF
    In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold. © 2015 Axel Loewe et al

    High-density mapping reveals short-term reversibility of atrial ablation lesions

    Get PDF
    Cardiac arrhythmias such as atrial fibrillation occur frequently in industrialized countries. Radiofrequency ablation (RFA) is a standard treatment if drug therapy fails. This minimally invasive surgery aims at stabilizing the heart rhythm on a permanent basis. However, the procedure commonly needs to be repeated because of the high recurrence rate of arrhythmias. Non-transmural lesions as well as gaps within linear lesions are among the main problems during the RFA. The assessment of lesion formation is not adequate in state of the art procedures. Therefore, the aim of this study is to investigate the short-term reversibility of lesions using human electrograms recorded by a high-density mapping system during an electrophysiological study (EPS). A predefined measurement protocol was executed during the EPS in order to create three ablation points in the left atrium. Subsequently, after preprocessing the recorded signals, electrogram (EGM) paths were formed along the endocardial surface of the atrium. By analyzing changes of peak to peak amplitudes of unipolar EGMs before and after ablation, it was possible to distinguish lesion area and healthy myocardium. The peak to peak amplitudes of the EGMs decreased by 40-61% after 30 seconds of ablation. Furthermore, we analyzed the morphological changes of EGMs surrounding the lesion. High-density mapping data showed that not only the tissue, which had direct contact with the catheter tip during the RFA, but also the surrounding tissue was affected. This was demonstrated by low peak to peak amplitudes in large areas with a width of 14 mm around the center of the ablation lesion. After right pulmonary vein isolation, high-density mapping was repeated on the previous lesions. The outer region of RFA-treated tissue appears to recover as opposed to the central core of the ablation point. This observation suggests that the meaningfulness of an immediate remap after ablation during an EPS may lead the physician to false conclusions

    Characterization of complex fractionated atrial electrograms by sample entropy: An international multi-center study

    Get PDF
    Atrial fibrillation (AF) is the most commonly clinically-encountered arrhythmia. Catheter ablation of AF is mainly based on trigger elimination and modification of the AF substrate. Substrate mapping ablation of complex fractionated atrial electrograms (CFAEs) has emerged to be a promising technique. To improve substrate mapping based on CFAE analysis, automatic detection algorithms need to be developed in order to simplify and accelerate the ablation procedures. According to the latest studies, the level of fractionation has been shown to be promisingly well estimated from CFAE measured during radio frequency (RF) ablation of AF. The nature of CFAE is generally nonlinear and nonstationary, so the use of complexity measures is considered to be the appropriate technique for the analysis of AF records. This work proposes the use of sample entropy (SampEn), not only as a way to discern between non-fractionated and fractionated atrial electrograms (A-EGM), but also as a tool for characterizing the degree of A-EGM regularity, which is linked to changes in the AF substrate and to heart tissue damage. The use of SampEn combined with a blind parameter estimation optimization process enables the classification between CFAE and non-CFAE with statistical significance (p < 0:001), 0.89 area under the ROC, 86% specificity and 77% sensitivity over a mixed database of A-EGM combined from two independent CFAE signal databases, recorded during RF ablation of AF in two EU countries (542 signals in total). On the basis of the results obtained in this study, it can be suggested that the use of SampEn is suitable for real-time support during navigation of RF ablation of AF, as only 1.5 seconds of signal segments need to be analyzed
    corecore