Dedicated Breast Computed Tomography With a Photon-Counting Detector: Initial Results of Clinical In Vivo Imaging
OBJECTIVES:
The purpose of this work is to present the data obtained from the first clinical in vivo application of a new dedicated spiral breast computed tomography (B-CT) equipped with a photon-counting detector.
MATERIALS AND METHODS:
The institutional review board approved this retrospective study. Twelve women referred for breast cancer screening were included and underwent bilateral spiral B-CT acquired in prone position. Additional sonography was performed in case of dense breast tissue or any B-CT findings. In 3 women, previous mammography was available for comparison. Soft tissue (ST) and high-resolution (HR) images were reconstructed. Two independent radiologists performed separately the readout for subjective image quality and for imaging findings detection. Objective image quality evaluation was performed in consensus and included spatial resolution, contrast resolution, signal-to-noise ratio (SNR), and contrast-to-noise ratio. All women were asked to report about positioning comfort and overall comfort during data acquisition.
RESULTS:
The major pectoral muscle was included in 15 breast CT scans (62.5%); glandular component was partially missing in 2 (8.3%) of the 24 scanned breasts. A thin "ring artifact" was present in all scans but had no influence on image interpretations; no other artifacts were present. Subjective image quality assessment showed excellent agreement between the 2 readers (κ = 1). Three masses were depicted in B-CT and were confirmed as simple cysts in sonography. Additional 5 simple cysts and 2 solid benign lesions were identified only in sonography. A total of 12 calcifications were depicted with a median size of 1.1 mm (interquartile range, 0.7-1.7 mm) on HR and 1.4 mm (interquartile range, 1.1-1.8 mm) on ST images. Median SNRgl, SNRfat, and contrast-to-noise ratio were significantly higher in ST than in HR reconstructions (each, P < 0.001). A mild discomfort due to positioning of the rib cage on the table was reported by 2 women (16.7%); otherwise, no discomfort was reported.
CONCLUSIONS:
The new dedicated B-CT equipped with a photon-counting detector provides high-quality images with potential for screening of breast cancer along with minor patient discomfort
Angiofil®-mediated visualization of the vascular system by microcomputed tomography: a feasibility study
Visualization of the vascular systems of organs or of small animals is important for an assessment of basic physiological conditions, especially in studies that involve genetically manipulated mice. For a detailed morphological analysis of the vascular tree, it is necessary to demonstrate the system in its entirety. In this study, we present a new lipophilic contrast agent, Angiofil®, for performing postmortem microangiography by using microcomputed tomography. The new contrast agent was tested in 10 wild-type mice. Imaging of the vascular system revealed vessels down to the caliber of capillaries, and the digital three-dimensional data obtained from the scans allowed for virtual cutting, amplification, and scaling without destroying the sample. By use of computer software, parameters such as vessel length and caliber could be quantified and remapped by color coding onto the surface of the vascular system. The liquid Angiofil® is easy to handle and highly radio-opaque. Because of its lipophilic abilities, it is retained intravascularly, hence it facilitates virtual vessel segmentation, and yields an enduring signal which is advantageous during repetitive investigations, or if samples need to be transported from the site of preparation to the place of actual analysis, respectively. These characteristics make Angiofil® a promising novel contrast agent; when combined with microcomputed tomography, it has the potential to turn into a powerful method for rapid vascular phenotyping
Computed tomography-osteoabsorptiometry for assessing the density distribution of subchondral bone as a measure of long-term mechanical adaptation in individual joints
To estimate subchondral mineralisation patterns which represent the long-term loading history of individual joints, a method has been developed employing computed tomography (CT) which permits repeated examination of living joints. The method was tested on 5 knee, 3 sacroiliac, 3 ankle and 5 shoulder joints and then investigated with X-ray densitometry. A CT absorptiometric presentation and maps of the area distribution of the subchondral bone density areas were derived using an image analyser. Comparison of the results from both X-ray densitometry and CT-absorptiometry revealed almost identical pictures of distribution of the subchondral bone density. The method may be used to examine subchondral mineralisation as a measure of the mechanical adaptability of joints in the living subject
An Analysis by Synthesis Approach for Automatic Vertebral Shape Identification in Clinical QCT
Quantitative computed tomography (QCT) is a widely used tool for osteoporosis
diagnosis and monitoring. The assessment of cortical markers like cortical bone
mineral density (BMD) and thickness is a demanding task, mainly because of the
limited spatial resolution of QCT. We propose a direct model based method to
automatically identify the surface through the center of the cortex of human
vertebra. We develop a statistical bone model and analyze its probability
distribution after the imaging process. Using an as-rigid-as-possible
deformation we find the cortical surface that maximizes the likelihood of our
model given the input volume. Using the European Spine Phantom (ESP) and a high
resolution \mu CT scan of a cadaveric vertebra, we show that the proposed
method is able to accurately identify the real center of cortex ex-vivo. To
demonstrate the in-vivo applicability of our method we use manually obtained
surfaces for comparison.Comment: Presented on German Conference on Pattern Recognition (GCPR) 2018 in
Stuttgar
Magnification, dust and time-delay constraints from the first resolved strongly lensed Type Ia supernova
We report lensing magnifications, extinction, and time-delay estimates for the first resolved, multiply-imaged Type Ia supernova iPTF16geu, at z = 0.409, using Hubble Space Telescope (HST) observations in combination with supporting ground-based data. Multi-band photometry of the resolved images provides unique information about the differential dimming due to dust in the lensing galaxy. Using HST and Keck AO reference images taken after the SN faded, we obtain a total lensing magnification for iPTF16geu of μ = 67.8^(+2.6)_(−2.9), accounting for extinction in the host and lensing galaxy. As expected from the symmetry of the system, we measure very short time-delays for the three fainter images with respect to the brightest one: -0.23 ± 0.99, -1.43 ± 0.74 and 1.36 ± 1.07 days. Interestingly, we find large differences between the magnifications of the four supernova images, even after accounting for uncertainties in the extinction corrections: Δm_1 = −3.88^(+0.07)_(−0.06), Δm_2 = −2.99^(+0.09)_(−0.08), Δm_3 = −2.19^(+0.14)_(−0.15) and Δm_4 = −2.40^(+0.14)_(−0.12) mag, discrepant with model predictions suggesting similar image brightnesses. A possible explanation for the large differences is gravitational lensing by substructures, micro- or millilensing, in addition to the large scale lens causing the image separations. We find that the inferred magnification is insensitive to the assumptions about the dust properties in the host and lens galaxy
- …