1,167 research outputs found
Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device
This review focuses on the development, current techniques, and clinical use of continuous intravascular blood gas monitoring (CIBM) devices in anaesthesia and intensive care. The operating principles, range of application, performance, limitations, costs, and impact on patient treatment and outcome, are discussed. Studies of early and currently available CIBM devices were analysed. At present, the Paratrend 7+® (PT7+®) for adults and Neotrend™ (NT™) for newborns are the only commercially available CIBM systems. The PT7+® contains three optical sensors to measure Po2, Pco2 and pH, as well as a thermocouple to measure temperature. The NT™ is a modification of the PT7+® to continuously monitor Po2, Pco2, pH and temperature in newborns. Under laboratory conditions, good performance over a wide range of blood gas values was observed with the Paratrend 7® (PT7®). Performance in the clinical setting was not as satisfactory, especially for Po2 values. However, the performance and accuracy of CIBM devices appear to be sufficient for clinical use and they are being used clinically in selected patient groups. Several factors affecting the performance of CIBM are considered. Br J Anaesth 2003: 91; 397-40
Continuous intravascular blood gas monitoring: development, current techniques, and clinical use of a commercial device
This review focuses on the development, current techniques, and clinical use of continuous intravascular blood gas monitoring (CIBM) devices in anaesthesia and intensive care. The operating principles, range of application, performance, limitations, costs, and impact on patient treatment and outcome, are discussed. Studies of early and currently available CIBM devices were analysed. At present, the Paratrend 7+® (PT7+®) for adults and Neotrend™ (NT™) for newborns are the only commercially available CIBM systems. The PT7+® contains three optical sensors to measure Po2, Pco2 and pH, as well as a thermocouple to measure temperature. The NT™ is a modification of the PT7+® to continuously monitor Po2, Pco2, pH and temperature in newborns. Under laboratory conditions, good performance over a wide range of blood gas values was observed with the Paratrend 7® (PT7®). Performance in the clinical setting was not as satisfactory, especially for Po2 values. However, the performance and accuracy of CIBM devices appear to be sufficient for clinical use and they are being used clinically in selected patient groups. Several factors affecting the performance of CIBM are considered. Br J Anaesth 2003: 91; 397-40
Distributed Formal Concept Analysis Algorithms Based on an Iterative MapReduce Framework
While many existing formal concept analysis algorithms are efficient, they
are typically unsuitable for distributed implementation. Taking the MapReduce
(MR) framework as our inspiration we introduce a distributed approach for
performing formal concept mining. Our method has its novelty in that we use a
light-weight MapReduce runtime called Twister which is better suited to
iterative algorithms than recent distributed approaches. First, we describe the
theoretical foundations underpinning our distributed formal concept analysis
approach. Second, we provide a representative exemplar of how a classic
centralized algorithm can be implemented in a distributed fashion using our
methodology: we modify Ganter's classic algorithm by introducing a family of
MR* algorithms, namely MRGanter and MRGanter+ where the prefix denotes the
algorithm's lineage. To evaluate the factors that impact distributed algorithm
performance, we compare our MR* algorithms with the state-of-the-art.
Experiments conducted on real datasets demonstrate that MRGanter+ is efficient,
scalable and an appealing algorithm for distributed problems.Comment: 17 pages, ICFCA 201, Formal Concept Analysis 201
Towards a generalisation of formal concept analysis for data mining purposes
In this paper we justify the need for a generalisation of Formal
Concept Analysis for the purpose of data mining and begin the
synthesis of such theory. For that purpose, we first review semirings and
semimodules over semirings as the appropriate objects to use in abstracting
the Boolean algebra and the notion of extents and intents, respectively.
We later bring to bear powerful theorems developed in the field
of linear algebra over idempotent semimodules to try to build a Fundamental
Theorem for K-Formal Concept Analysis, where K is a type of
idempotent semiring. Finally, we try to put Formal Concept Analysis in
new perspective by considering it as a concrete instance of the theory
developed
Clones in Graphs
Finding structural similarities in graph data, like social networks, is a
far-ranging task in data mining and knowledge discovery. A (conceptually)
simple reduction would be to compute the automorphism group of a graph.
However, this approach is ineffective in data mining since real world data does
not exhibit enough structural regularity. Here we step in with a novel approach
based on mappings that preserve the maximal cliques. For this we exploit the
well known correspondence between bipartite graphs and the data structure
formal context from Formal Concept Analysis. From there we utilize
the notion of clone items. The investigation of these is still an open problem
to which we add new insights with this work. Furthermore, we produce a
substantial experimental investigation of real world data. We conclude with
demonstrating the generalization of clone items to permutations.Comment: 11 pages, 2 figures, 1 tabl
Präoperative Nüchternzeiten: Sicht der Patienten
Zusammenfassung: Hintergrund: Mit dem Ziel der subjektiven perioperativen Qualitätsverbesserung scheint es wünschenswert, die präoperativen Nüchternzeiten im Rahmen der als sicher geltenden Grenzen so kurz als möglich zu halten. Diese Maßnahmen sollten mit einer messbaren Verminderung von präoperativem Hunger und Durst einhergehen und v.a. in einer Verbesserung der präoperativen Befindlichkeit resultieren. Welchen Einfluss Durst und Hunger aus Patientensicht auf den präoperativen Komfort haben, ist jedoch weit gehend unbekannt. Ziel dieser Studie war es, das Ausmaß der Beeinträchtigung der Patienten durch eine traditionelle Nüchternheitsregelung abzuschätzen. Patienten und Methoden: Ein Kollektiv von 412Patienten der "American-Society-of-Anesthesiologists"- (ASA-)RisikoklassenI und II, das sich einem kleineren chirurgischen Eingriff unterzog, wurde mithilfe eines Fragebogens zum Ausmaß und Stellenwert von präoperativem Durst und Hunger befragt. Ergebnisse: Es hatten 33% der Patienten mäßigen oder starken Durst, 19% mäßigen bis starken Hunger. Von den Befragten möchten 47% vor der Operation noch trinken, 72% hätten gern noch ein leichtes Frühstück eingenommen. Die mittlere Nüchternzeit war 12,8±3,4h für Flüssigkeiten und 15,5±4,4h für Essen. Durst wurde von 3,3% und Hunger von 0,8% der Patienten als Hauptgrund für die Beeinträchtigung des präoperativen Wohlbefindens genannt. Das lange Warten (8,5%), Nervosität (6,5%) und Angst (4,8%) wurden am häufigsten genannt. Die Antworten waren unabhängig von der Zeitdauer der präoperativen Nüchternheit. Schlussfolgerung: Der Patientenkomfort ist durch eine traditionelle Nüchternheitsregelung beeinträchtigt, und Minimierung der präoperativen Nüchternzeiten wird von den Patienten gewünscht. Anstrengungen mit dem Ziel der Reduktion von präoperativer Angst und Nervosität bergen jedoch zusätzliches großes Potenzial für eine Steigerung der perioperativen Behandlungsqualität aus Sicht der Patiente
APPLICABILITY OF A FULL BODY INERTIAL MEASUREMENT SYSTEM FOR KINEMATIC ANALYSIS OF THE DISCUS THROW
The aim of the study was the application of a full body inertial measurement system (IMS) for a kinematic analysis of the discus throw and the evaluation of its applicability. For this purpose, one male sports student performed three discus throws equipped with the IMS. All trials were additionally filmed by high-speed video. The results indicate that perfor-mance-relevant information can be obtained regarding the temporal coordination of the body segments and body joint angles. Limitations exist for the accurate detection of the last foot contact related instant and the discus release instant by solely using the IMS data
A coproduct structure on the formal affine Demazure algebra
In the present paper we generalize the coproduct structure on nil Hecke rings
introduced and studied by Kostant-Kumar to the context of an arbitrary
algebraic oriented cohomology theory and its associated formal group law. We
then construct an algebraic model of the T-equivariant oriented cohomology of
the variety of complete flags.Comment: 28 pages; minor revision of the previous versio
Empirical comparison of high gradient achievement for different metals in DC and pulsed mode
For the SwissFEL project, an advanced high gradient low emittance gun is
under development. Reliable operation with an electric field, preferably above
125 MV/m at a 4 mm gap, in the presence of an UV laser beam, has to be achieved
in a diode configuration in order to minimize the emittance dilution due to
space charge effects. In the first phase, a DC breakdown test stand was used to
test different metals with different preparation methods at voltages up to 100
kV. In addition high gradient stability tests were also carried out over
several days in order to prove reliable spark-free operation with a minimum
dark current. In the second phase, electrodes with selected materials were
installed in the 250 ns FWHM, 500 kV electron gun and tested for high gradient
breakdown and for quantum efficiency using an ultra-violet laser.Comment: 25 pages, 13 figures, 5 tables. Follow up from FEL 2008 conference
(Geyongju Korea 2008) New Title in JVST A (2010) : Vacuum breakdown limit and
quantum efficiency obtained for various technical metals using DC and pulsed
voltage source
- …