122 research outputs found

    A position- and time-sensitive photon-counting detector with delay-line read-out

    Get PDF
    We have developed image intensifier tubes with delay-anode read-out for time- and position-sensitive photon counting. The timing precision is better than 1 ns with 1000x1000 pixels position resolution and up to one megacounts/s processing rate. Large format detectors of 40 and 75 mm active diameter with internal helical-wire delay-line anodes have been produced and specified. A different type of 40 and 25 mm tubes with semi-conducting screen for image charge read-out allow for an economic and robust tube design and for placing the read-out anodes outside the sealed housing. Two types of external delay-line anodes, i.e. pick-up electrodes for the image charge, have been tested. We present tests of the detector and anode performance. Due to the low background this technique is well suited for applications with very low light intensity and especially if a precise time tagging for each photon is required. As an example we present the application of scintillator read-out in time-of-flight (TOF) neutron radiography. Further applications so far are Fluorescence Life-time Microscopy (FLIM) and AstronomyComment: Proceedings of SPIE Conference "Optics and Optoelectronics", 16 - 19. Apr.200

    Molecular frame photoelectron angular distribution for oxygen 1s photoemission from CO_2 molecules

    Get PDF
    We have measured photoelectron angular distributions in the molecular frame (MF-PADs) for O 1s photoemission from CO2, using photoelectron-O+–CO+ coincidence momentum imaging. Results for the molecular axis at 0, 45 and 90° to the electric vector of the light are reported. The major features of the MF-PADs are fairly well reproduced by calculations employing a relaxed-core Hartree–Fock approach. Weak asymmetric features are seen through a plane perpendicular to the molecular axis and attributed to symmetry lowering by anti-symmetric stretching motion

    Breakdown of the Two-Step Model in K-Shell Photoemission and Subsequent Decay Probed by the Molecular-Frame Photoelectron Angular Distributions of CO_2

    Get PDF
    We report results of measurements and of Hartree-Fock level calculations of molecular-frame photoelectron angular distributions (MFPADs) for C 1s photoemission from CO2. The agreement between the measured and calculated MFPADs is on average reasonable. The measured MFPADs display a weak but definite asymmetry with respect to the O+ and CO+ fragment ions at certain energies, providing evidence for an overlap of gerade and ungerade final ionic states giving rise to a partial breakdown of the two-step model of core-level photoionization and its subsequent Auger decay

    Carbon K-shell photoelectron angular distribution from fixed-in-space CO2 molecules

    Get PDF
    Measurements of photoelectron angular distributions for carbon K-shell ionization of fixed-in-space CO2 molecules with the molecular axis oriented along, perpendicular and at 45 degrees to the electric vector of the light are reported. The major features of these measured spectra are fairly well reproduced by calculations employing a relaxed-core Hartree-Fock approach. In contrast to the angular distribution for K-shell ionization of N-2, which exhibits a rich structure dominated by the f-wave (l = 3) at the shape resonance, the angular distribution for carbon K-shell photoionization of CO2 is quite unstructured over the entire observed range across the shape resonance
    • …