657 research outputs found
Разработка прецизионных устройств исполнительной автоматики для космических аппаратов со сроком активного существования не менее 15,5 лет
Обеспечение безопасности радиоактивных источников на гипотетическом объекте
Объектом исследования является вопросы организации и функционирования систем физической защиты, учета и контроля ядерных материалов.
Целью работы является создание методического подхода для описания и построения гипотетического объекта и его систем безопасности, с дальнейшем его применением в учебных целях по специальности Безопасность и нераспространение ядерных материалов.The object of research is the organization and functioning of systems of physical protection, accounting and control of nuclear materials.
The aim of the work is to create a methodological approach to the description and construction of a hypothetical object and its security systems, with its further application for educational purposes in the specialty safety and non-proliferation of nuclear materials
Modular Lie algebras and the Gelfand-Kirillov conjecture
Let g be a finite dimensional simple Lie algebra over an algebraically closed
field of characteristic zero. We show that if the Gelfand-Kirillov conjecture
holds for g, then g has type A_n, C_n or G_2.Comment: 20 page
Geometry, topology and dynamics of geodesic flows on noncompact polygonal surfaces
We establish the background for the study of geodesics on noncompact
polygonal surfaces. For illustration, we study the recurrence of geodesics on
-periodic polygonal surfaces. We prove, in particular, that almost all
geodesics on a topologically typical -periodic surface with boundary are
recurrent.Comment: 34 pages, 13 figures. To be published in V. V. Kozlov's Festschrif
Effects of mesenchymal stromal cells versus serum on tendon healing in a controlled experimental trial in an equine model
Abstract Background Mesenchymal stromal cells (MSC) have shown promising results in the treatment of tendinopathy in equine medicine, making this therapeutic approach seem favorable for translation to human medicine. Having demonstrated that MSC engraft within the tendon lesions after local injection in an equine model, we hypothesized that they would improve tendon healing superior to serum injection alone. Methods Quadrilateral tendon lesions were induced in six horses by mechanical tissue disruption combined with collagenase application 3 weeks before treatment. Adipose-derived MSC suspended in serum or serum alone were then injected intralesionally. Clinical examinations, ultrasound and magnetic resonance imaging were performed over 24 weeks. Tendon biopsies for histological assessment were taken from the hindlimbs 3 weeks after treatment. Horses were sacrificed after 24 weeks and forelimb tendons were subjected to macroscopic and histological examination as well as analysis of musculoskeletal marker expression. Results Tendons injected with MSC showed a transient increase in inflammation and lesion size, as indicated by clinical and imaging parameters between week 3 and 6 (p < 0.05). Thereafter, symptoms decreased in both groups and, except that in MSC-treated tendons, mean lesion signal intensity as seen in T2w magnetic resonance imaging and cellularity as seen in the histology (p < 0.05) were lower, no major differences could be found at week 24. Conclusions These data suggest that MSC have influenced the inflammatory reaction in a way not described in tendinopathy studies before. However, at the endpoint of the current study, 24 weeks after treatment, no distinct improvement was observed in MSC-treated tendons compared to the serum-injected controls. Future studies are necessary to elucidate whether and under which conditions MSC are beneficial for tendon healing before translation into human medicine
Tracking of autologous adipose tissue-derived mesenchymal stromal cells with in vivo magnetic resonance imaging and histology after intralesional treatment of artificial equine tendon lesions - a pilot study
Background: Adipose tissue-derived mesenchymal stromal cells (AT-MSCs) are frequently used to treat equine tendinopathies. Up to now, knowledge about the fate of autologous AT-MSCs after intralesional injection into equine superficial digital flexor tendons (SDFTs) is very limited. The purpose of this study was to monitor the presence of intralesionally injected autologous AT-MSCs labelled with superparamagnetic iron oxide (SPIO) nanoparticles and green fluorescent protein (GFP) over a staggered period of 3 to 9 weeks with standing magnetic resonance imaging (MRI) and histology. Methods: Four adult warmblood horses received a unilateral injection of 10 × 106 autologous AT-MSCs into surgically created front-limb SDFT lesions. Administered AT-MSCs expressed lentivirally transduced reporter genes for GFP and were co-labelled with SPIO particles in three horses. The presence of AT-MSCs in SDFTs was evaluated by repeated examinations with standing low-field MRI in two horses and post-mortem in all horses with Prussian blue staining, fluorescence microscopy and with immunofluorescence and immunohistochemistry using anti-GFP antibodies at 3, 5, 7 and 9 weeks after treatment. Results: AT-MSCs labelled with SPIO particles were detectable in treated SDFTs during each MRI in T2*- and T1-weighted sequences until the end of the observation period. Post-mortem examinations revealed that all treated tendons contained high numbers of SPIO- and GFP-labelled cells. Conclusions: Standing low-field MRI has the potential to track SPIO-labelled AT-MSCs successfully. Histology, fluorescence microscopy, immunofluorescence and immunohistochemistry are efficient tools to detect labelled AT-MSCs after intralesional injection into surgically created equine SDFT lesions. Intralesional injection of 10 × 106 AT-MSCs leads to the presence of high numbers of AT-MSCs in and around surgically created tendon lesions for up to 9 weeks. Integration of injected AT-MSCs into healing tendon tissue is an essential pathway after intralesional administration. Injection techniques have to be chosen deliberately to avoid reflux of the cell substrate injected. In vivo low-field MRI may be used as a non-invasive tool to monitor homing and engraftment of AT-MSCs in horses with tendinopathy of the SDFT
Low recurrence rate of a two-layered closure repair for primary and recurrent midline incisional hernia without mesh
Background: Incisional hernia is a serious complication after abdominal surgery and occurs in 11-23% of laparotomies. Repair can be done, for instance, with a direct suture technique, but recurrence rates are high. Recent literature advises the use of mesh repair. In contrast to this development, we studied the use of a direct suture repair in a separate layer technique. The objective of this retrospective observational study is to assess the outcomes (recurrences and complications) of a two-layered open closure repair for primary and recurrent midline incisional hernia without the use of mesh. Methods: In an observational retrospective cohort study, we analysed the hospital and outpatient records of 77 consecutive patients who underwent surgery for a primary or recurrent incisional hernia between 1st May 2002 and 8th November 2006. The repair consisted of separate continuous suturing of the anterior and posterior fascia, including the rectus muscle, after extensive intra-abdominal adhesiolysis. Results: Forty-one men (53.2%) and 36 women (46.8%) underwent surgery. Sixty-three operations (81.8%) were primary repairs and 14 (18.2%) were repairs for a recurrent incisional hernia. Of the 66 patients, on physical examination, three had a recurrence (4.5%) after an average follow-up of 2.6 years. The 30-day postoperative mortality was 1.1%. Wound infection was seen in five patients (6.5%). Conclusions: A two-layered suture repair for primary and recurrent incisional hernia repair without mesh with extensive adhesiolysis was associated with a recurrence rate comparable to mesh repair and had an acceptable complication rate
Ergodicity of certain cocycles over certain interval exchanges
We show that for odd-valued piecewise-constant skew products over a certain
two parameter family of interval exchanges, the skew product is ergodic for a
full-measure choice of parameters
Non-stationary compositions of Anosov diffeomorphisms
Motivated by non-equilibrium phenomena in nature, we study dynamical systems
whose time-evolution is determined by non-stationary compositions of chaotic
maps. The constituent maps are topologically transitive Anosov diffeomorphisms
on a 2-dimensional compact Riemannian manifold, which are allowed to change
with time - slowly, but in a rather arbitrary fashion. In particular, such
systems admit no invariant measure. By constructing a coupling, we prove that
any two sufficiently regular distributions of the initial state converge
exponentially with time. Thus, a system of the kind loses memory of its
statistical history rapidly
- …
