62 research outputs found

    A novel multivariate STeady-state index during general ANesthesia (STAN)

    Get PDF
    The assessment of the adequacy of general anesthesia for surgery, namely the nociception/anti-nociception balance, has received wide attention from the scientific community. Monitoring systems based on the frontal EEG/EMG, or autonomic state reactions (e.g. heart rate and blood pressure) have been developed aiming to objectively assess this balance. In this study a new multivariate indicator of patients' steady-state during anesthesia (STAN) is proposed, based on wavelet analysis of signals linked to noxious activation. A clinical protocol was designed to analyze precise noxious stimuli (laryngoscopy/intubation, tetanic, and incision), under three different analgesic doses; patients were randomized to receive either remifentanil 2.0, 3.0 or 4.0 ng/ml. ECG, PPG, BP, BIS, EMG and [Formula: see text] were continuously recorded. ECG, PPG and BP were processed to extract beat-to-beat information, and [Formula: see text] curve used to estimate the respiration rate. A combined steady-state index based on wavelet analysis of these variables, was applied and compared between the three study groups and stimuli (Wilcoxon signed ranks, Kruskal-Wallis and Mann-Whitney tests). Following institutional approval and signing the informed consent thirty four patients were enrolled in this study (3 excluded due to signal loss during data collection). The BIS index of the EEG, frontal EMG, heart rate, BP, and PPG wave amplitude changed in response to different noxious stimuli. Laryngoscopy/intubation was the stimulus with the more pronounced response [Formula: see text]. These variables were used in the construction of the combined index STAN; STAN responded adequately to noxious stimuli, with a more pronounced response to laryngoscopy/intubation (18.5-43.1 %, [Formula: see text]), and the attenuation provided by the analgesic, detecting steady-state periods in the different physiological signals analyzed (approximately 50 % of the total study time). A new multivariate approach for the assessment of the patient steady-state during general anesthesia was developed. The proposed wavelet based multivariate index responds adequately to different noxious stimuli, and attenuation provided by the analgesic in a dose-dependent manner for each stimulus analyzed in this study.The first author was supported by a scholarship from the Portuguese Foundation for Science and Technology (FCT SFRH/BD/35879/2007). The authors would also like to acknowledge the support of UISPA—System Integration and Process Automation Unit—Part of the LAETA (Associated Laboratory of Energy, Transports and Aeronautics) a I&D Unit of the Foundation for Science and Technology (FCT), Portugal. FCT support under project PEst-OE/EME/LA0022/2013.info:eu-repo/semantics/publishedVersio

    Short-term complexity indexes of heart period and systolic arterial pressure variabilities provide complementary information

    Get PDF
    It is unclear whether the complexity of the variability of the systolic arterial pressure (SAP) provides complementary information to that of the heart period (HP). The complexity of HP and SAP variabilities was assessed from short beat-to-beat recordings (i.e., 256 cardiac beats). The evaluation was made during a pharmacological protocol that induced vagal blockade with atropine or a sympathetic blockade (beta-Adrenergic blockade with propranolol or central sympathetic blockade with clonidine) alone or in combination, during a graded head-up tilt, and in patients with Parkinson's disease (PD) without orthostatic hypotension undergoing orthostatic challenge. Complexity was quantified according to the mean square prediction error (MSPE) derived from univariate autoregressive (AR) and multivariate AR (MAR) models. We found that: 1) MSPEMAR did not provide additional information to that of MSPE AR; 2) SAP variability was less complex than that of HP; 3) because HP complexity was reduced by either vagal blockade or vagal withdrawal induced by head-up tilt and was unaffected by beta-Adrenergic blockade, HP was under vagal control; 4) because SAP complexity was increased by central sympathetic blockade and was unmodified by either vagal blockade or vagal withdrawal induced by head-up tilt, SAP was under sympathetic control; 5) SAP complexity was increased in patients with PD; and 6) during orthostatic challenge, the complexity of both HP and SAP variabilities in patients with PD remained high, thus indicating both vagal and sympathetic impairments. Complexity indexes derived from short HP and SAP beat-to-beat series provide complementary information and are helpful in detecting early autonomic dysfunction in patients with PD well before circulatory symptoms become noticeable

    The protocol of the Oslo Study of Clonidine in Elderly Patients with Delirium; LUCID:a randomised placebo-controlled trial

    Get PDF
    Background Delirium affects 15% of hospitalised patients and is linked with poor outcomes, yet few pharmacological treatment options exist. One hypothesis is that delirium may in part result from exaggerated and/or prolonged stress responses. Dexmedetomidine, a parenterally-administered alpha2-adrenergic receptor agonist which attenuates sympathetic nervous system activity, shows promise as treatment in ICU delirium. Clonidine exhibits similar pharmacodynamic properties and can be administered orally. We therefore wish to explore possible effects of clonidine upon the duration and severity of delirium in general medical inpatients. Methods/Design The Oslo Study of Clonidine in Elderly Patients with Delirium (LUCID) is a randomised, placebo-controlled, double-blinded, parallel group study with 4-month prospective follow-up. We will recruit 100 older medical inpatients with delirium or subsyndromal delirium in the acute geriatric ward. Participants will be randomised to oral clonidine or placebo until delirium free for 2 days (Diagnostic and Statistical Manual of Mental Disorders (DSM-5) criteria), or after a maximum of 7 days treatment. Assessment of haemodynamics (blood pressure, heart rate and electrocardiogram) and delirium will be performed daily until discharge or a maximum of 7 days after end of treatment. The primary endpoint is the trajectory of delirium over time (measured by Memorial Delirium Assessment Scale). Secondary endpoints include the duration of delirium, use of rescue medication for delirium, pharmacokinetics and pharmacodynamics of clonidine, cognitive function after 4 months, length of hospital stay and need for institutionalisation. Discussion LUCID will explore the efficacy and safety of clonidine for delirium in older medical inpatients. Trial registration ClinicalTrials.gov NCT01956604 . EudraCT Number: 2013-000815-2

    Initial magnetic field distribution around high rectangular bus bars

    No full text
    The one-dimensional transient electromagnetic field in and around a system of two nonmagnetic homogenous rectangular high thin bars can be analytically evaluated if the ratio of average initial magnetic field on the two sides of thin bar, or of the ratio of initial magnetic fields in middle of the bar height is known. In this paper, using appropriate conformal mappings, an exact analytical solution for these ratios are proposed in the case of very thin bars. Obtained values are compared with FEM results for relatively thick bars

    Resistance of arbitrary angle corner

    No full text
    The field modelling becomes simpler if strong field nonuniformities are solved theoretically. The early-obtained formulas for 2-D "corner" permeances, (capacitances or resistances) pertain to right angle configurations. In this paper, using a conformal mapping and analytical approximations, the field in the vicinity of arbitrary angle corner is studied and the corner resistance determined. Obtained results can be applied to a large range of electromagnetic and microelectronic devices. They agree with early-obtained values for right angle corner and with the FEM simulation
    corecore