4,967 research outputs found
Development status of the LAUE project
We present the status of LAUE, a project supported by the Italian Space
Agency (ASI), and devoted to develop Laue lenses with long focal length (up to
100 meters), for hard X--/soft gamma--ray astronomy (80-600 keV). Thanks to
their focusing capability, the design goal is to improve the sensitivity of the
current instrumention in the above energy band by 2 orders of magnitude, down
to a few times photons/(cm s keV).Comment: 9 pages, 9 figures, presented at the Space Telescopes and
Instrumentation Symposium in Amsterdam, 2012: Ultraviolet to Gamma Ray
Conference. Published in the Proceedings of the SPIE, Volume 8443, id.
84430B-84430B-9 (2012
The practices of apartheid as a war crime: a critical analysis
The human suffering caused by the political ideology of apartheid in South Africa during the Apartheid era (1948-1994) prompted worldwide condemnation and a variety of diplomatic and legal responses. Amongst these responses was the attempt to have apartheid recognised both as a crime against humanity in the 1973 Apartheid Convention as well as a war crime in Article 85(4)(c) of Additional Protocol I. This article examines the origins, nature and current status of the practices of apartheid as a war crime and its possible application to the Israeli-Palestinian conflict
New development: Directly elected mayors in Italy: creating a strong leader doesn’t mean creating strong leadership
More than 20 years after their introduction, directly elected mayors are key players in Italian urban governance. This article explains the main effects of this reform on local government systems and provides lessons for other countries considering directly elected mayors
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
We present a novel application of Fiber Bragg Grating (FBG) sensors in the
construction and characterisation of Micro Pattern Gaseous Detector (MPGD),
with particular attention to the realisation of the largest triple (Gas
electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the
CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of
about 0.5 m2 active area each, employing three GEM foils per chamber, to be
installed in the forward region of the CMS endcap during the long shutdown of
LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM
foils that are mechanically stretched in order to secure their flatness and the
consequent uniform performance of the GE1/1 chamber across its whole active
surface. So far FBGs have been used in high energy physics mainly as high
precision positioning and re-positioning sensors and as low cost, easy to
mount, low space consuming temperature sensors. FBGs are also commonly used for
very precise strain measurements in material studies. In this work we present a
novel use of FBGs as flatness and mechanical tensioning sensors applied to the
wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used
to determine the optimal mechanical tension applied and to characterise the
mechanical tension that should be applied to the foils. We discuss the results
of the test done on a full-sized GE1/1 final prototype, the studies done to
fully characterise the GEM material, how this information was used to define a
standard assembly procedure and possible future developments.Comment: 4 pages, 4 figures, presented by Luigi Benussi at MPGD 2015 (Trieste,
Italy). arXiv admin note: text overlap with arXiv:1512.0848
The NA62 RICH detector
The NA62 experiment is designed to measure the very rare kaon decay K+ → π+ν¯ν at the CERN SPS with a 10% accuracy. The Standard Model prediction for the branching ratio is (8.5±0.7)×10−11. One of the challenging aspects of the experiment is the suppression of the K+ → μ+νμ background at the 10−12 level. To satisfy this requirement a Ring Imaging Cherenkov Detector (RICH), able to separate π± from μ± in the momentum range between 15 and 35 GeV/c, with a μ misidentification probability better than 10−2, is needed. The RICH must also have a time resolution of about 100 ps to disentangle accidental time associations of beam particles with pions. The RICH will have a very long focal length (17m) and will be filled with Ne gas at atmospheric pressure. Two tests beam were held at CERN in 2007 and 2009 with a RICH prototype. The results of the two tests beam
will be presented: the μ misidentification probability is found to be about 0.7% and the time resolution better than 100 ps in the whole momentum range
REMAXINT: a two-mode clustering-based method for statistical inference on two-way interaction
Design of a constant fraction discriminator for the VFAT3 front-end ASIC of the CMS GEM detector
In this work the design of a constant fraction discriminator (CFD) to be used in the VFAT3 chip for the read-out of the triple-GEM detectors of the CMS experiment, is described. A prototype chip containing 8 CFDs was implemented using 130 nm CMOS technology and test results are shown. © CERN 2016
Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment
The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System
Gas Electron Multiplier (GEM) technology is being considered for the forward
muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first
implementation is planned for the GE1/1 system in the region of the muon endcap mainly to control muon level-1 trigger rates
after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by
3,072 radial strips with 455 rad pitch arranged in eight -sectors.
We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and
tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO 70:30 and
the RD51 scalable readout system. Four small GEM detectors with 2-D readout and
an average measured azimuthal resolution of 36 rad provided precise
reference tracks. Construction of this largest GEM detector built to-date is
described. Strip cluster parameters, detection efficiency, and spatial
resolution are studied with position and high voltage scans. The plateau
detection efficiency is [97.1 0.2 (stat)]\%. The azimuthal resolution is
found to be [123.5 1.6 (stat)] rad when operating in the center of
the efficiency plateau and using full pulse height information. The resolution
can be slightly improved by 10 rad when correcting for the bias due
to discrete readout strips. The CMS upgrade design calls for readout
electronics with binary hit output. When strip clusters are formed
correspondingly without charge-weighting and with fixed hit thresholds, a
position resolution of [136.8 2.5 stat] rad is measured, consistent
with the expected resolution of strip-pitch/ = 131.3 rad. Other
-sectors of the detector show similar response and performance.Comment: 8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci.
Symposium, Seattle, WA, reference adde
- …
