    The costs of tax relief for New York agricultural landowners is compared with the willingness-to-pay for farmland protection as measured in valuation research. Under an income tax rebate, the program cost is positively related with the perceived household benefits, whereas this trend is reversed under a local property tax exemption.Agricultural and Food Policy, Public Economics,

    A dynamic model of Venus's gravity field

    Get PDF
    Unlike Earth, long wavelength gravity anomalies and topography correlate well on Venus. Venus's admittance curve from spherical harmonic degree 2 to 18 is inconsistent with either Airy or Pratt isostasy, but is consistent with dynamic support from mantle convection. A model using whole mantle flow and a high viscosity near surface layer overlying a constant viscosity mantle reproduces this admittance curve. On Earth, the effective viscosity deduced from geoid modeling increases by a factor of 300 from the asthenosphere to the lower mantle. These viscosity estimates may be biased by the neglect of lateral variations in mantle viscosity associated with hot plumes and cold subducted slabs. The different effective viscosity profiles for Earth and Venus may reflect their convective styles, with tectonism and mantle heat transport dominated by hot plumes on Venus and by subducted slabs on Earth. Convection at degree 2 appears much stronger on Earth than on Venus. A degree 2 convective structure may be unstable on Venus, but may have been stabilized on Earth by the insulating effects of the Pangean supercontinental assemblage

    What is required to measure the wear of explanted metal on metal hips?

    Get PDF
    Abstract INTRODUCTION There is increasing worldwide interest in the assessment of wear in explanted hip components. This is due is part to high profile failures of orthopaedic components in the US, whilst in the UK hip resurfacings have been experiencing a higher than expected failure rate. The reasons for these failures are not well understood, with data from the NJR suggesting the 43% of MoM resurfacing failures are unexplained. Wear analysis is a vital tool in determining failure mechanisms and ultimately improving the longevity of joint replacements through improved design and manufacturing control. There are currently no relevant measurement standards for the evaluation of retrieved orthopaedic components. This paper will assess two of the most commonly used techniques namely roundness measurement and co-ordinate measurement. The advantages and disadvantages of both techniques are considered in this paper. ROUNDNESS MACHINE The Talyrond 365 is a stylus based roundness machine. The component is located on a rotating table and the stylus measures the deviation from a perfect circle as the component is slowly rotated. The Talyrond measures a single profile to an accuracy of 30 nm and up to 72,000 data points per revolution. The air spindle has a radial accuracy of <0.02 μm and the Talymin gauge a minimum resolution of 12 nm. Individual roundness profiles can be stitched together to build up 3D cylinder maps, allowing 3D pictures of sections of explanted hip components to be generated. COORDINATE MEASURING MACHINE Co-ordinate measuring machines (CMMs) have been widely used in manufacturing quality and research departments for a number of years and the CMM is recognised as a powerful and important tool capable of ascertaining geometric data from a component. The CMM used in this study was a Zeiss Prismo CMM (Carl Zeiss Ltd., Rugby, UK) with a probing error of 0.7 μm. Components are securely held in a chuck fixture arrangement and the dimensions of the component in the portion of the bearing that is unworn is ascertained through measurement. The initial measurements are used to produce a reverse engineered 3D CAD surface which represents the component ‘pre-wear’ surface. The surface of the component is then scanned and the deviation from this pre-wear surface is mapped. The maximum linear wear and wear volume are then calculated directly. DISCUSSION The main advantage of CMM and Talyrond is that they are available in most metrology and measurement rooms. The CMM is a particularly versatile machine and can be used to measure any orthopaedic components. There is a need to develop a suitable Standard for both machines detailing a protocol to measure explanted hip and quantify the wear. A study is underway to measure a set of explanted hip components to allow a detailed comparison between of measurements between the Talyrond and CMM. The result of this study will be included in the paper. CONCLUSIONS The CMM and Talyrond are both instruments suited to measuring wear of explanted hips. A full evaluation of the systems and the development of robust measurement protocol and standard would be advantageous to the orthopaedic industry

    Systematic Review of Preclinical Surgical Meshes for Hernia Repair

    Get PDF
    Hernia repair is one of the most common procedures performed around the world. Surgical mesh materials are used to reinforce hernia repairs and improve surgical outcomes. However, current commercial mesh materials produce problems such as infection, rejection, shrinkage, adhesion, and mechanical failure. These problems contribute to a high rate of hernia recurrence and mesh removal. With the number of hernias expected to rise in the future due to increases in obesity and diabetes, the need for more effective mesh materials is critical. This review aims to identify, evaluate, and summarize experimental surgical mesh materials used in the preclinical stages of development and catalogue their characteristics and the tests used for their evaluation.https://digitalcommons.unmc.edu/surp2021/1053/thumbnail.jp

    Material Loss at the Head Taper Junction of the Metal-on-Metal Pinnacle Total Hip Replacement

    Get PDF
    Introduction The ASR XL (DePuy) total hip replacement (THR) is a notable example of a modern metal-on-metal (MOM) implant design that has demonstrated unacceptable survival rates, leading to its recall by the manufacturer; national joint registries have reported revision rates at 7 years of 40% when paired with the Corail stem [1]. The ASR XL THR has a considerably greater risk of revision than the ASR resurfacing hip, which used the same bearing design. This suggests that material loss at the head-stem junction may be responsible for the greater percentage of THR failures observed in this design. The Pinnacle MOM-THR (DePuy) however used the same Corail stem as the ASR XL THR but demonstrated better clinical results, with revision rates of less than 10% at 7 years [1]. The ASR XL and MOM Pinnacle are two designs that have been widely used in hip replacement surgery. The reasons for the differences in the failure rates of the two designs are not fully understood. Comparing the mechanisms of failure of both hips will help surgeons understand whether patients with MOM Pinnacle hips will experience the same types of problems as with those seen with the ASR XL. The aims of this retrieval study were to investigate the significance of differences between the ASR XL and MOM Pinnacle in relation to: (1) pre-revision whole blood Co/Cr ratios, (2) visual evidence of taper corrosion, (3) volumetric material loss at the bearing surfaces and (4) volumetric material loss at the taper surfaces. Methods This study involved a series of failed MOM hips consisting of the ASR XL (n=30) and Pinnacle (n=30), all that had been used with a Corail stem. The bearing material in each design was cobalt-chromium and the Corail stem is of a cementless titanium 12/14 design. The ASR XL and Pinnacle had a median head diameter of 47mm (39-55) and 36mm (36-40) respectively, and a median time to revision of 38.5 months (12-74) and 55 months (14-86) respectively. Pre-revision whole blood metal ion levels were collected for each Table 1 summarises patient and implant data for the hips in this study. The female taper surfaces of all 60 heads were examined macroscopically and microscopically to assess the severity of corrosion. Each surface was graded with a score of between 1 (no corrosion) and 4 (severe corrosion) using a well-published scoring system, which has been shown to be statistically reliable. A Zeiss Prismo (Carl Zeiss Ltd, Rugby, UK) coordinate measuring machine (CMM) was used to determine the volume of material loss at the cup and head bearing surfaces. Up to 300,000 data points were collected using a 2mm ruby stylus that was translated along 400 polar scan lines on the surface. The raw data was used to map regions of material loss by comparing with the unworn geometry of the bearing. A Talyrond 365 (Hobson, Leicester, UK) roundness measuring machine was used to measure the volumetric material loss at each of the head taper surfaces. Published protocols were used to take a series of 180 vertical traces along the taper surface using a 5μm diamond stylus; worn and unworn regions were mapped and used to calculate material loss. Neither the volumetric measurement data nor corrosion scores were normally distributed. Therefore non-parametric tests were performed to assess the statistical significance of differences between the two designs in relation to the parameters under investigation in this study. Results Both the whole blood Co ion levels and the Co/Cr ratios, Figure 1, of the ASR XL hips were significantly greater than the Pinnacles (p<0.05). There was no significant difference between the whole blood Cr ion levels between the two designs (p=0.0542). 18 of the ASR XL hips presented evidence of edge wearing of the cup, compared with 14 Pinnacle hips; this difference was not significant (p=0.438). The length of the stem trunnion contact engagement length with the taper was approximated as being 10.5mm for both designs. The median time to revision of the ASR XL hips was significantly less than the Pinnacle hips (p<0.01). There was visual evidence of corrosion in 93% (n=28) and 90% (n=27) of head tapers for the ASR XLs and Pinnacles respectively. Moderate to severe corrosion was observed in 67% (n=20) of ASR XLs compared to 60% (n=18) of Pinnacles. There was however no statistically significant difference between the scores of the two groups (p=0.927). Figure 2 presents the distribution of material loss rates for the bearing and taper surfaces of the two designs in this study. The median total bearing surface (combined cup and head) rate of material loss for the ASR XL and Pinnacle hips was 4.45mm3/year (0.32-22.85) and 4.03mm3/year (0.87-62.12) respectively. There was no significant difference between the two groups (p=0.928). The median material loss rate at the taper surfaces of the ASR XL and Pinnacle hips was 0.62mm3/year (0-4.20) and 0.30mm3/year (0-3.12); this difference was not significant (p=0.198). Discussion The work of this study presents comparisons of retrieval findings between the ASR XL and Pinnacle MOM-THRs; these hip designs were two of the most commonly implanted in patients worldwide. The significantly greater whole blood Co/Cr ratios found in the ASR XL group compared to the Pinnacle group are of interest. It is speculated that a Co/Cr ratio of greater than 1 may be an indicator of corrosion of an implant whereby more Cr ions are retained on the surface, whilst comparatively more Co ions are released into the blood. In the current study we found wear rates at the bearing surfaces of both designs to be comparable, suggesting that the significantly greater Co/Cr ratios in the ASR XL hips must be due to greater corrosion at the taper junction than the Pinnacles. Although the ASR XL hips had been implanted for a significantly shorter period of time, our visual assessment of the corrosion of the taper junctions found that corrosion scores were comparable between the two designs; indeed, a marginally greater number of ASR XL tapers had evidence of moderate to severe corrosion. This finding, coupled with the elevated Co/Cr ratios suggests that the ASR XL design is more susceptible to corrosion at the taper junction than the Pinnacle hip. We found that the median rate of material loss at the ASR XL taper was over twice that of the Pinnacle taper. Whilst not statistically significant, this difference may be due to a greater risk of corrosion at this interface in the ASR XL design. The differences in material loss and corrosion that were observed at the taper junctions may be explained by considering the larger head sizes of the ASR XL hips in comparison to the Pinnacles. It has previously been shown that increasing head size is correlated with greater visual evidence of corrosion and that increased frictional torque along the taper junction due a larger head diameter can increase the risk of fretting-corrosion. It is suggested therefore that the combination of the larger head sizes of the ASR XLs coupled with the comparatively short, rough surface of the Corail trunnion results in a cumulative effect leading to greater corrosion at the taper junction. Significance The results of the study suggest that the combination of (1) increased frictional torque in the larger ASR XLs and (2) the rough Corail trunnion surface, results in greater corrosion at the taper junction in comparison to the Pinnacle hips; this helps to explain the higher risk of revision in this hip design

    Identifying The Pattern of Material Loss at the Head-Neck Junction Wear Helps Determine the Mechanism of Failure of Metal on Metal Total Hip Replacements

    Get PDF
    Material loss at the Head-Neck junction accounts for a third of the total volume material loss in contemporary metal-on-metal total hip replacements. It is speculated that the material loss is the result of corrosion and mechanical wear (fretting). High volumes of material loss have been reported, especially from the head taper. There is only one report on characterizing the pattern of material loss and this was in a very small number of cases (n=5). Our aim was to identify the different material loss patterns at the head taper and their corresponding mechanisms We retrospectively analysed a series of retrieved Large Head Metal on Metal Total Hip Replacements (155 cups, 155 femoral heads and 4 stems). We measured material loss on the bearing surfaces and the head-neck junction using well-published metrology methods. Furthermore we collected patient (age, gender and time of primary/revision operations), pre-revision (cobalt and chromium blood metal ion, oxford hip score, cup orientation and implant position) implant (cup and head size, manufacturer and corrosion severity) data. Finally we used surface analysis techniques (microscopy and spectroscopy) to identify fretting, imprinting and the material composition of debris. We devised a novel four-group classification and two blinded engineers classified the material loss patterns using wear maps derived from the metrology analysis We observed four distinct patterns of taper surface material loss at our retrieval centre and we set out to characterize these types and relate them to patient, implant and clinical variables. The four groups of material loss patterns were defined as: (1) Low wear (n= 63), (2) Open-end band (n=32), (3) Stripped material loss (n=54) and (4) Coup-Countercoup (n=6) (Figure). The Interobserver Reliability Kappa score was 0.78 (p<0.001) indicating substantial agreement between the two examiners. Analysis of variables between the groups identified significantly different head sizes (highest: Group 2, p=0.000), corrosion severity (highest: Group 2, p=0.004) and time to revision (highest: Group 3, p=0.040). We identified four different material loss patterns each with its own mechanism. Corrosion was identified as the principal mechanism in Groups 1 and 3. Group 1 head-neck junctions are thought to have a better seal with less fluid ingress in the junction. Group 3 head-neck junctions are attacked by corrosion either circumferentially, or unilaterally, along the whole engagement length. Mechanically assisted corrosion was the principal mechanism in Group 2. The higher friction torque opens up the open-end part of the junction and the ingressing fluid accelerates the corrosion. Extensive fretting was also observed under the scanning electron microscope. Intra-operative surgical damage was identified as the principal mechanism in Group 4, with only 6 components. The patterns and the mechanisms of material loss at the head-neck junction contribute to the understanding of large head metal-on-metal hip replacements. As a result, better implants can be designed in the future. Clinically, these findings suggest that head size and head taper-trunnion fit are the main factors that determine the longevity of the head-neck junction. On the other hand, patients selection does not influence the integrity of the junction

    De Novo Microdeletion Spanning YWHAE and CRK in an Individual with Intellectual Disability and Stunted Growth

    Get PDF
    In this report, we present a case of a 20-year-old female with congenital intellectual disability, stunted growth, and hypothyroidism. Competitive genetic hybridization (CHG) revealed a loss of a portion of 17p13.3 at least 195 Kb in size, not present in either parent. This area of chromosome 17 is associated with Miller-Dieker Syndrome (MDS) and Isolated Lissencephaly Sequence (ILS), but these conditions are related predominantly to PAFAH1B1, which is not included in the patient’s deletion

    Library Buildings And The Building Of A Collaborative Research Collection At The Tri-College Library Consortium

    Get PDF
    This report is the product of a planning grant awarded by The Andrew W. Mellon Foundation in 2001 to the Tri-College Library Consortium, which comprises the libraries of Bryn Mawr, Haverford and Swarthmore Colleges. The grant proposal, entitled “Library Buildings and the Building of a Collaborative Research Collection at the Tri-Colleges,” set out a research agenda designed to address two central questions. The first question was a challenge: How could the three libraries come to terms with space problems caused by ever-growing collections and increasing demands to accommodate media, teaching, and student study areas in an environment in which library building expansion was a remote possibility? The second question was an opportunity: Could the libraries take advantage of their history of cooperation and the powerful tool of a unified online catalog to create a single research-quality collection out of the combined holdings of three strong liberal arts colleges? Working with a consultant, a seven-member Planning Group representing the three colleges and the consortium gathered data on the collections, convened focus groups of faculty and students, and engaged three publishing industry experts to assess the state of electronic publishing. After analyzing the data, the Planning Group studied alternatives for maximizing collection space and made recommendations for new models and strategies to be pursued by the Tri-Colleges consortium

    Using Geological Implications of a Physical Libration to Constrain Enceladus' Libration State

    Get PDF
    Observations of Enceladus' south pole revealed large rifts in the crust, called "tiger stripes", which exhibit higher temperatures than the surrounding terrain and are likely sources of observed eruptions. Tidal stress may periodically open the tiger stripe rifts, controlling the timing and location of eruptions. Moreover, shear motion along rifts may produce the heat to drive eruptions
    corecore