6 research outputs found

    Efficacy and safety of Armolipid Plus®: an updated PRISMA compliant systematic review and meta-analysis of randomized controlled clinical trials.

    Get PDF
    Armolipid Plus® is a multi-constituent nutraceutical that claims to improve lipid profiles. The aim of this PRISMA compliant systematic review and meta-analysis was to globally evaluate the efficacy and safety of Armolipid Plus® on the basis of the available randomized, blinded, controlled clinical trials (RCTs). A systematic literature search in several databases was conducted in order to identify RCTs assessing the efficacy and safety of dietary supplementation with Armolipid Plus®. Two review authors independently identified 12 eligible studies (1050 included subjects overall) and extracted data on study characteristics, methods, and outcomes. Meta-analysis of the data suggested that dietary supplementation with Armolipid Plus® exerted a significant effect on body mass index (mean difference (MD) = -0.25 kg/m2, p = 0.008) and serum levels of total cholesterol (MD = -25.07 mg/dL, p < 0.001), triglycerides (MD = -11.47 mg/dL, p < 0.001), high-density lipoprotein cholesterol (MD = 1.84 mg/dL, p < 0.001), low-density lipoprotein cholesterol (MD = -26.67 mg/dL, p < 0.001), high sensitivity C reactive protein (hs-CRP, MD = -0.61 mg/L, p = 0.022), and fasting glucose (MD = -3.52 mg/dL, p < 0.001). Armolipid Plus® was well tolerated. This meta-analysis demonstrates that dietary supplementation with Armolipid Plus® is associated with clinically meaningful improvements in serum lipids, glucose, and hs-CRP. These changes are consistent with improved cardiometabolic health

    Safety Evaluation of α-Lipoic Acid Supplementation: A Systematic Review and Meta-Analysis of Randomized Placebo-Controlled Clinical Studies.

    Get PDF
    Alpha-lipoic acid (ALA) is a natural short-chain fatty acid that has attracted great attention in recent years as an antioxidant molecule. However, some concerns have been recently raised regarding its safety profile. To address the issue, we aimed to assess ALA safety profile through a systematic review of the literature and a meta-analysis of the available randomized placebo-controlled clinical studies. The literature search included EMBASE, PubMed Medline, SCOPUS, Google Scholar, and ISI Web of Science by Clarivate databases up to 15th August 2020. Data were pooled from 71 clinical studies, comprising 155 treatment arms, which included 4749 subjects with 2558 subjects treated with ALA and 2294 assigned to placebo. A meta-analysis of extracted data suggested that supplementation with ALA was not associated with an increased risk of any treatment-emergent adverse event (all p > 0.05). ALA supplementation was safe, even in subsets of studies categorized according to smoking habit, cardiovascular disease, presence of diabetes, pregnancy status, neurological disorders, rheumatic affections, severe renal impairment, and status of children/adolescents at baseline

    The Ultrasound Window Into Vascular Ageing: A Technology Review by the VascAgeNet COST Action

    Get PDF
    Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker

    An exploratory enalysis of the relation between metabolic syndrome factors and microRNA data

    No full text
    The metabolic syndrome (MetS) is associated with increased risk for cardiovascular disease. The detection and treatment of the underlying factors of the metabolic syndrome have a significant influence on the reduction of the cardiovascular disease. In this study, we analyze relations between MetS components and RNA molecules (microRNAs) regulating gene expression at the posttranscriptional level, in order to determine the predictive value of different microRNAs for subjects with metabolic syndrome. We apply correlation and linear regression to analyze the relationship between microRNAs and selected arterial markers. Logistic regression models were used to explore the statistical relationship between microRNAs and categorical variables. Results show that statistically significant linear relationship exists between arterial markers and several microRNAs, however, the observed relationship is very weak (<0.25). Since cardiovascular diseases are usually multifactorial diseases, caused by various mechanisms, it is more likely, that the combination of microRNAs will have stronger predictional or diagnostic power. Moreover, it is possible that more valuable results can be obtained by analyzing relations between microRNAs and binary variable determining the absence/existence of metabolic syndrome. Hence, we plan to use canonical correlation analysis to investigate linear combinations of microRNAs which have a maximum correlation with arterial markersBaltijos pažangių technologijų institutasBaltijos pažangių technologijų institutas, VilniusTaikomosios informatikos katedraVilniaus universitetasVytauto Didžiojo universiteta

    The Ultrasound Window Into Vascular Ageing:A Technology Review by the VascAgeNet COST Action

    No full text
    Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker
    corecore