998,880 research outputs found
Faculty recital by Robert Gartside, tenor with Keith Humble, pianist, March 10, 1970
This is the concert program of Faculty Recital by Robert Gartside, tenor with Keith Humble, pianist on Tuesday, March 10, 1970 at 8:30 p.m., at the Concert Hall, 855 Commonwealth Avenue. Works performed were Belle Qui Tiens Ma Vie by Anonymous XVI Century, Nicolas Va Voir Jeanne by Anonymous XVII Century, L'amour De Moi by Anonymous XV Century, Say, Love, If Ever Thou Dudst Find by John Dowland, Sorrow, Stay by J. Dowland, Lady, If You So Spite Me by J. Dowland, Ronsard A Son Ame by Maurice Ravel, Deux Epigrammes De Clemet Marot by M. Ravel, Deux Melodies Hebraiques by M. Ravel, Trois Poemes D'Amour De Pierre Albert-Birot by Keith Humble, The Housatonic At Stockbridge by Charles Ives, Two Little Flowers (and dedicated to them) by C. Ives, An Election by C. Ives, In Disen Wintertagen (op. 14) by Arnold Schoenberg, Jane Grey by A. Schoenberg, Mein Wagen Rollet Langsam by Robert Schumann, Geständnis (op. 74) by R. Schumann, and Aufträge (op. 77) by R. Schumann. Digitization for Boston University Concert Programs was supported by the Boston University Humanities Library Endowed Fund
Results of the engineering run of the coherent neutrino nucleus interaction experiment (CONNIE)
The CONNIE detector prototype is operating at a distance of 30 m from the core of a 3.8 GWth nuclear reactor with the goal of establishing Charge-Coupled Devices (CCD) as a new technology for the detection of coherent elastic neutrino-nucleus scattering. We report on the results of the engineering run with an active mass of 4 g of silicon. The CCD array is described, and the performance observed during the first year is discussed. A compact passive shield was deployed around the detector, producing an order of magnitude reduction in the background rate. The remaining background observed during the run was stable, and dominated by internal contamination in the detector packaging materials. The in-situ calibration of the detector using X-ray lines from fluorescence demonstrates good stability of the readout system. The event rates with the reactor ON and OFF are compared, and no excess is observed coming from nuclear fission at the power plant. The upper limit for the neutrino event rate is set two orders of magnitude above the expectations for the standard model. The results demonstrate the cryogenic CCD-based detector can be remotely operated at the reactor site with stable noise below2 e RMS and stable background rates. The success of the engineering test provides a clear path for the upgraded 100 g detector to be deployed during 2016.Fil: Aguilar Arevalo, A.. Universidad Nacional Autónoma de México; MéxicoFil: Bertou, Xavier Pierre Louis. Comisión Nacional de Energía Atómica; Argentina. Comisión Nacional de Energía Atómica. Fundación José A. Balseiro; ArgentinaFil: Bonifazi, C.. Universidade Federal do Rio de Janeiro; BrasilFil: Butner, M.. Fermi National Accelerator Laboratory; Estados UnidosFil: Cancelo, G.. Fermi National Accelerator Laboratory; Estados UnidosFil: Castañeda Vazquez, A.. Universidad Nacional Autónoma de México; MéxicoFil: Cervantes Vergara, B.. Universidad Nacional Autónoma de México; MéxicoFil: Chavez, C. R.. Universidad Nacional de Asunción; ParaguayFil: Da Motta, H.. Centro Brasileiro de Pesquisas Físicas; BrasilFil: D'Olivo, J. C.. Universidad Nacional Autónoma de México; MéxicoFil: Dos Anjos, J.. Centro Brasileiro de Pesquisas Físicas; BrasilFil: Estrada, J.. Fermi National Accelerator Laboratory; Estados UnidosFil: Fernández Moroni, Guillermo. Universidad Nacional del Sur. Departamento de Ingeniería Eléctrica y de Computadoras. Instituto ; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Ford, R.. Fermi National Accelerator Laboratory; Estados UnidosFil: Foguel, A.. Centro Brasileiro de Pesquisas Físicas; Brasil. Universidade Federal do Rio de Janeiro; BrasilFil: Hernandez Torres, K. P.. Universidad Nacional Autónoma de México; MéxicoFil: Izraelevitch, F.. Fermi National Accelerator Laboratory; Estados UnidosFil: Kavner, A.. University of Michigan; Estados UnidosFil: Kilminster, B.. Universitat Zurich; SuizaFil: Kuk, K.. Fermi National Accelerator Laboratory; Estados UnidosFil: Lima Jr, H. P.. Centro Brasileiro de Pesquisas Físicas; BrasilFil: Makler, M.. Centro Brasileiro de Pesquisas Físicas; BrasilFil: Molina, J.. Universidad Nacional de Asunción; ParaguayFil: Moreno Granados, G.. Universidad Nacional Autónoma de México; MéxicoFil: Moro, Juan Manuel. Universidad Nacional del Sur. Departamento de Ingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Paolini, Eduardo Emilio. Universidad Nacional del Sur. Departamento de Ingeniería Eléctrica y de Computadoras. Instituto ; ArgentinaFil: Sofo Haro, Miguel Francisco. Comision Nacional de Energia Atomica. Gerencia D/area de Energia Nuclear; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Tiffenberg, Javier Sebastian. Fermi National Accelerator Laboratory; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas; ArgentinaFil: Trillaud, F.. Universidad Nacional Autónoma de México; MéxicoFil: Wagner, S.. Centro Brasileiro de Pesquisas Físicas; Brasil. Pontificia Universidade Católica do Rio Grande do Sul; Brasi
A Test of Photometric Redshifts for X-ray Selected Sources
We test the effectiveness of photometric redshifts based upon galaxy spectral
template fitting for X-ray luminous objects, using a sample of 65 sources
detected by Chandra in the field of the Caltech Faint Galaxy Redshift Survey
(CFGRS). We find that sources with quasar-dominated spectra (for which galaxy
spectral templates are not appropriate) are easily identified, and that
photometric redshifts are robust for the rest of the sources in our sample.
Specifically, for the 59 sources that are not quasar-dominated at optical
wavelengths, we find that the photometric redshift estimates have scatter
comparable to the field galaxy population in this region. There is no evidence
for a trend of increasing dispersion with X-ray luminosity over the range L_X =
10^39 - 5x10^43 erg/s, nor is there a trend with the ratio of X-ray to optical
flux, f_X/f_R. The practical implication of this work is that photometric
redshifts should be robust for the majority (~90%) of the X-ray sources down to
f_X ~ 10^-16 erg/s/cm^2 that have optical counterparts brighter than R ~ 24.
Furthermore, the same photometry can be easily used to identify the sources for
which the photometric redshifts are likely to fail. Photometric redshift
estimation can thus be utilized as an efficient tool in analyzing the
statistical properties of upcoming large Chandra and XMM-Newton data sets and
identifying interesting subsamples for further study.Comment: To appear in ApJ (6 pages, 6 figures). Replaced with accepted versio
José María López Piñero desde la historia de la Filosofía
Este ensayo examina brevemente la obra historiográfica de J. M. López Piñero en el ámbito de la ciencia y la técnica en la España de los siglos XVI y XVII. Se resaltan los siguientes puntos fundamentales de dicha obra: inserción en un proyecto ideal de 'historia total' de acuerdo con el modelo trazado por Pierre Vilar; superación de la dicotomía 'externalismo' /'internalismo'; vinculación recíproca de ciencia y técnica como realidades sociales; atención a la institucionalización de la práctica científica y técnica; trabajo historiográfico en equipo
Analysis of cosmic ray variations observed by the CARPET in association with solar flares in 2011-2012
The CARPET cosmic ray detector was installed on April 2006 at CASLEO (Complejo Astronmico El Leoncito) at the Argentinean Andes (31.8S, 69.3W, 2550 m, Rc=9.65 GV). This instrument was developed within an international cooperation between the Lebedev Physical Institute RAS (LPI; Russia), the Centro de Radio Astronomia e Astrofsica Mackenzie (CRAAM; Brazil) and the Complejo Astronmico el Leoncito (CASLEO; Argentina). In this paper we present results of analysis of cosmic ray variations recorded by the CARPET during increased solar flare activity in 2011-2012. Available solar and interplanetary medium observational data obtained onboard GOES, FERMI, ISS, as well as cosmic ray measurements by ground-based neutron monitor network were also used in the present analysis.Fil: Makhmutov, V.. Lebedev Physical Institute; Rusia. Universidade Presbiteriana Mackenzie; BrasilFil: Raulin, J. P.. Universidade Presbiteriana Mackenzie; BrasilFil: De Mendonca, R. R. S.. National Institute for Space Research; BrasilFil: Bazilevskaya, G. A.. Lebedev Physical Institute; RusiaFil: Correia, E.. Universidade Presbiteriana Mackenzie; Brasil. National Institute for Space Research; BrasilFil: Kaufmann, Pierre. Universidade Presbiteriana Mackenzie; BrasilFil: Marun, Adolfo Hector. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Juan. Complejo Astronómico "El Leoncito". Universidad Nacional de Córdoba. Complejo Astronómico "El Leoncito". Universidad Nacional de la Plata. Complejo Astronómico "El Leoncito". Universidad Nacional de San Juan. Complejo Astronómico "El Leoncito"; ArgentinaFil: Fernandez, German Enzo Leonel. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Juan. Complejo Astronómico "El Leoncito". Universidad Nacional de Córdoba. Complejo Astronómico "El Leoncito". Universidad Nacional de la Plata. Complejo Astronómico "El Leoncito". Universidad Nacional de San Juan. Complejo Astronómico "El Leoncito"; ArgentinaFil: Echer, E.. National Institute for Space Research; Brasi
Site-specific alteration of murine hepatitis virus type 4 peplomer glycoprotein E2 results in reduced neurovirulence
Atmospheric Calorimetry above 10 eV: Shooting Lasers at the Pierre Auger Cosmic-Ray Observatory
The Pierre Auger Cosmic-Ray Observatory uses the earth's atmosphere as a
calorimeter to measure extensive air-showers created by particles of
astrophysical origin. Some of these particles carry joules of energy. At these
extreme energies, test beams are not available in the conventional sense. Yet
understanding the energy response of the observatory is important. For example,
the propagation distance of the highest energy cosmic-rays through the cosmic
microwave background radiation (CMBR) is predicted to be strong function of
energy. This paper will discuss recently reported results from the observatory
and the use of calibrated pulsed UV laser "test-beams" that simulate the
optical signatures of ultra-high energy cosmic rays. The status of the much
larger 200,000 km companion detector planned for the northern hemisphere
will also be outlined.Comment: 6 pages, 11 figures XIII International Conference on Calorimetry in
High Energy Physic
Correlation energy of two electrons in the high-density limit
We consider the high-density-limit correlation energy \Ec in
dimensions for the ground states of three two-electron systems: helium
(in which the electrons move in a Coulombic field), spherium (in which they
move on the surface of a sphere), and hookium (in which they move in a
quadratic potential). We find that the \Ec values are strikingly similar,
depending strongly on but only weakly on the external potential. We
conjecture that, for large , the limiting correlation energy \Ec \sim
-\delta^2/8 in any confining external potential, where .Comment: 4 pages, 0 figur
Chemistry in One Dimension
We report benchmark results for one-dimensional (1D) atomic and molecular
systems interacting via the Coulomb operator . Using various
wavefunction-type approaches, such as Hartree-Fock theory, second- and
third-order M{\o}ller-Plesset perturbation theory and explicitly correlated
calculations, we study the ground state of atoms with up to ten electrons as
well as small diatomic and triatomic molecules containing up to two electrons.
A detailed analysis of the 1D helium-like ions is given and the expression of
the high-density correlation energy is reported. We report the total energies,
ionization energies, electron affinities and other interesting properties of
the many-electron 1D atoms and, based on these results, we construct the 1D
analog of Mendeleev's periodic table. We find that the 1D periodic table
contains only two groups: the alkali metals and the noble gases. We also
calculate the dissociation curves of various 1D diatomics and study the
chemical bond in H, HeH, He, H, HeH and
He. We find that, unlike their 3D counterparts, 1D molecules are
primarily bound by one-electron bonds. Finally, we study the chemistry of
H and we discuss the stability of the 1D polymer resulting from an
infinite chain of hydrogen atoms.Comment: 27 pages, 7 figure
- …
