637 research outputs found

    Open-circuit fault diagnosis and maintenance in multi-pulse parallel and series TRU topologies

    Get PDF
    ©2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.Transformer Rectifier Units (TRUs) are a reliable way for DC generation in several electric applications. These units are formed by multiple three-phase uncontrolled bridge rectifiers connected according to two main topologies (parallel and series), and fed by a phase-shifting transformer, which can have different configurations. Fault diagnosis of the uncontrolled bridge rectifier diodes is one of the most important concerns on the electronic devices, nonetheless, rectifier units are inherently not protected in front of Open-Circuit (O/C) faults, which cause malfunction and performance deterioration. In order to solve this drawback, the proposed fault diagnosis method is based on the O/C fault signature observed in the DC-link output voltage of TRUs rectifier. It allows detecting the O/C diodes of parallel and series TRUs with different phase-shifting transformer configurations and for the most usual fault scenarios. Moreover, it also helps the prediction of diodes that could be exposed to failure after the fault, which provides corrective maintenance for the TRU development. The proposed method is illustrated from MATLABTM numerical simulations of a 12-pulse TRU, and is validated with experimental tests.This work supported in part by the Research Project Estabilidad de Redes MVdc Integrando Tecnologias de Energias Renovables, Almacenamiento de Energia y Convertidores de Fuente de Impedancia, RTI2018-095720-B-C33, in part by the Ministerio de Ciencia, Innovación y Universidades, and in part by the European Union.Peer ReviewedPostprint (author's final draft

    A System-based Modeling and Simulation of a Floating Production Storage and Offloading (FPSO) Electric Power Systems and Core Loss Analysis of Synchronous Generator and Induction Motor

    Get PDF
    In this dissertation, a system based modeling and simulation were investigated for FPSO power system components and a few experimental results were evaluated to determine core losses in a synchronous generator under non-sinusoidal current. Modeling and simulation results are presented to predict both the utility and the motor side challenges caused by different harmonic distortion levels. VFD was modeled as a rectifier and an inverter isolated by the DC link in the middle of the rectifier and the inverter in order to have faster and more accurate analysis of harmonics on both the utility and the motor side. Finite element analysis shows that reducing current harmonic level causes lower core losses in the machine. Each component from the simulation, specifically synchronous generator, phase shifting transformer, multipulse rectifier, multilevel inverter, umbilical cable and induction motor, can be replaced or combined with any other topologies which is one of the biggest benefits of the system based modeling and simulation

    A System-based Modeling and Simulation of a Floating Production Storage and Offloading (FPSO) Electric Power Systems and Core Loss Analysis of Synchronous Generator and Induction Motor

    Get PDF
    In this dissertation, a system based modeling and simulation were investigated for FPSO power system components and a few experimental results were evaluated to determine core losses in a synchronous generator under non-sinusoidal current. Modeling and simulation results are presented to predict both the utility and the motor side challenges caused by different harmonic distortion levels. VFD was modeled as a rectifier and an inverter isolated by the DC link in the middle of the rectifier and the inverter in order to have faster and more accurate analysis of harmonics on both the utility and the motor side. Finite element analysis shows that reducing current harmonic level causes lower core losses in the machine. Each component from the simulation, specifically synchronous generator, phase shifting transformer, multipulse rectifier, multilevel inverter, umbilical cable and induction motor, can be replaced or combined with any other topologies which is one of the biggest benefits of the system based modeling and simulation

    Source Grid Interface of Wind Energy Systems

    Get PDF
    Wind power is one of the most developed and rapidly growing renewable energy sources. Through extensive literature review this thesis synthesizes the existing knowledge of wind energy systems to offer useful information to developers of such systems. Any prototyping should be preceded by theoretical analysis and computer simulations, foundations for which are provided here. The thesis is devoted to an in-depth analysis of wind energy generators, system configurations, power converters, control schemes and dynamic and steady state performance of practical wind energy conversion systems (WECS). Attention is mainly focused on interfacing squirrel cage Induction generators (SCIG) and doubly-fed induction generators (DFIG) with the power network to capture optimal power, provide controllable active and reactive power and minimize network harmonics using the two-level converter, as a power electronic converter. Control of active and reactive power, frequency and voltage are indispensable for stability of the grid. This thesis focuses on two main control techniques, field oriented control (FOC) and direct torque control (DTC) for the SCIG. The dynamic model of induction generator is non-linear and hence for all types of control, the flux and the torque have to be decoupled for maintaining linearity between input and output for achieving high dynamic performance. FOC is used for decoupled control for rotor flux and electromagnetic torque . The stator current is decomposed into flux and torque producing components and they both are controlled independently. FOC uses three feedback control loops generate gating signals for the converter. DTC also achieves high dynamic performance by decoupling of rotor flux and electromagnetic torque without the intermediate current loops. DTC asks for the estimation of stator flux and torque and like FOC has 2 branches which have flux and torque comparators. The errors between the set and the estimated value are used to drive the inverters. The two methods are valid for both steady and transient state. Their validity is confirmed by simulating the systems on MATLAB/Simulink platform and comparing them the results obtained by hand calculations. Further DFIG’s are introduced. The dynamic model is developed using the machines equivalent circuit and is expressed in the stationary, rotor and the synchronous reference frames for evaluating the performance of the machine. The stator of the DFIG is directly interfaced to the grid and by controlling the rotor voltage by a two level back-to-back converter the grid synchronization and power control is maintained. The DTC and the direct power control (DPC) methods are used to control the rotor side (RSC) and the grid side converter (GSC). The RSC generates the 3-ph voltages of variable frequency in order to control the generator torque and the reactive power exchanged between the stator and the grid. The GSC exchanges active power with the grid injected by the RSC with a constant frequency. The steady and transient behavior of the machine is investigated through simulations

    Soft-Switched Step-Up Medium Voltage Power Converters

    Get PDF
    With a ten-year average annual growth rate of 19 percent, wind energy has been the largest source of new electricity generation for the past decade. Typically, an offshore wind farm has a medium voltage ac (MVac) grid that collects power from individual wind turbines. Since the output voltage of a wind turbine is too low (i.e., typically 400 690 V) to be connected to the MVac grid (i.e., 20 40 kV), a heavy line-frequency transformer is used to step up the individual turbines output voltage to the MV level. To eliminate the need for bulky MVac transformers, researchers are gravitating towards the idea of replacing the MVac grid with a medium voltage dc (MVdc) grid, so that MV step-up transformers are replaced by MV step-up power electronic converters that operate at the medium frequency range with much lower size and weight. This dissertation proposes a class of modular step-up transformerless MV SiC-based power converters with soft-switching capability for wind energy conversion systems with MVdc grid. This dissertation consists of two parts: the first part focuses on the development of two novel groups of step-up isolated dc-dc MV converters that utilize various step-up resonant circuits and soft-switched high voltage gain rectifier modules. An integrated magnetic design approach is also presented to combine several magnetic components together in the modular high voltage gain rectifiers. The second part of this dissertation focuses on the development of several three-phase ac-dc step-up converters with integrated active power factor correction. In particular, a bridgeless input ac-dc rectifier is also proposed to combine with the devised step-up transformerless dc-dc converters (presented in the first part) to form the three-phase soft-switched ac-dc step-up voltage conversion unit. In each of the presented modular step-up converter configurations, variable frequency control is used to regulate the output dc voltage of each converter module. The operating principles and characteristics of each presented converter are provided in detail. The feasibility and performance of all the power converter concepts presented in this dissertation are verified through simulation results on megawatts (MW) design examples, as well as experimental results on SiC-based laboratory-scale proof-of-concept prototypes

    Soft-Switched Step-Up Medium Voltage Power Converters

    Get PDF
    With a ten-year average annual growth rate of 19 percent, wind energy has been the largest source of new electricity generation for the past decade. Typically, an offshore wind farm has a medium voltage ac (MVac) grid that collects power from individual wind turbines. Since the output voltage of a wind turbine is too low (i.e., typically 400 690 V) to be connected to the MVac grid (i.e., 20 40 kV), a heavy line-frequency transformer is used to step up the individual turbines output voltage to the MV level. To eliminate the need for bulky MVac transformers, researchers are gravitating towards the idea of replacing the MVac grid with a medium voltage dc (MVdc) grid, so that MV step-up transformers are replaced by MV step-up power electronic converters that operate at the medium frequency range with much lower size and weight. This dissertation proposes a class of modular step-up transformerless MV SiC-based power converters with soft-switching capability for wind energy conversion systems with MVdc grid. This dissertation consists of two parts: the first part focuses on the development of two novel groups of step-up isolated dc-dc MV converters that utilize various step-up resonant circuits and soft-switched high voltage gain rectifier modules. An integrated magnetic design approach is also presented to combine several magnetic components together in the modular high voltage gain rectifiers. The second part of this dissertation focuses on the development of several three-phase ac-dc step-up converters with integrated active power factor correction. In particular, a bridgeless input ac-dc rectifier is also proposed to combine with the devised step-up transformerless dc-dc converters (presented in the first part) to form the three-phase soft-switched ac-dc step-up voltage conversion unit. In each of the presented modular step-up converter configurations, variable frequency control is used to regulate the output dc voltage of each converter module. The operating principles and characteristics of each presented converter are provided in detail. The feasibility and performance of all the power converter concepts presented in this dissertation are verified through simulation results on megawatts (MW) design examples, as well as experimental results on SiC-based laboratory-scale proof-of-concept prototypes

    Soft-Switched Step-Up Medium Voltage Power Converters

    Get PDF
    With a ten-year average annual growth rate of 19 percent, wind energy has been the largest source of new electricity generation for the past decade. Typically, an offshore wind farm has a medium voltage ac (MVac) grid that collects power from individual wind turbines. Since the output voltage of a wind turbine is too low (i.e., typically 400 690 V) to be connected to the MVac grid (i.e., 20 40 kV), a heavy line-frequency transformer is used to step up the individual turbines output voltage to the MV level. To eliminate the need for bulky MVac transformers, researchers are gravitating towards the idea of replacing the MVac grid with a medium voltage dc (MVdc) grid, so that MV step-up transformers are replaced by MV step-up power electronic converters that operate at the medium frequency range with much lower size and weight. This dissertation proposes a class of modular step-up transformerless MV SiC-based power converters with soft-switching capability for wind energy conversion systems with MVdc grid. This dissertation consists of two parts: the first part focuses on the development of two novel groups of step-up isolated dc-dc MV converters that utilize various step-up resonant circuits and soft-switched high voltage gain rectifier modules. An integrated magnetic design approach is also presented to combine several magnetic components together in the modular high voltage gain rectifiers. The second part of this dissertation focuses on the development of several three-phase ac-dc step-up converters with integrated active power factor correction. In particular, a bridgeless input ac-dc rectifier is also proposed to combine with the devised step-up transformerless dc-dc converters (presented in the first part) to form the three-phase soft-switched ac-dc step-up voltage conversion unit. In each of the presented modular step-up converter configurations, variable frequency control is used to regulate the output dc voltage of each converter module. The operating principles and characteristics of each presented converter are provided in detail. The feasibility and performance of all the power converter concepts presented in this dissertation are verified through simulation results on megawatts (MW) design examples, as well as experimental results on SiC-based laboratory-scale proof-of-concept prototypes
    • …
    corecore