3 research outputs found

    Urban vertical air pollution gradient and dynamics investigated with low-cost sensors and large-eddy simulations

    Get PDF
    A network of five low-cost air pollution sensor (LCS) nodes was deployed vertically on the exterior of the H. C. Ørsted Institute at the University of Copenhagen, Denmark, to investigate the transport of pollution from the road below. All LCS nodes measured PM2.5, NO2, and O3 at 1-min time resolution, and one of them also measured noise. Traffic was monitored with a webcam, where traffic type and levels were derived using a machine-learning algorithm. We investigated how well traffic-related air pollution, noise, and real-time traffic counts serve as proxies for one another. The correlations between NO2, noise, and traffic count exhibited relatively low values when considering all the data. However, these correlations significantly increased under southwesterly wind direction and low wind speed, reaching R2 = 0.40 for NO2 and noise, R2 = 0.51 for NO2 and traffic volume, and R2 = 0.70 for noise and traffic volume. These results indicate a common source, namely traffic, for all three parameters. The five LCS nodes spanning 25 m vertically had extremely low intervariability with minimum R2-values of 0.98 for PM2.5, 0.89 for NO2, and 0.97 for O3. The system could not detect a vertical gradient in pollution levels. Large-eddy simulation model runs using the PALM model system generally supported the lack of gradient observed in measured observations. Under slightly unstable stratification, concentration remained relatively constant with height for southwesterly and southerly winds. Conversely, winds from the north, west, and northwest showed an increase in concentration with height. For other wind directions, the concentration decreased with height by approximately 40 % to 50 %, which is not as strong as for neutral stratification, attributed to enhanced vertical mixing under unstable stratification. Based on the measurements and modeling, we conclude that the vertical concentration profile is very sensitive to stratification, and under these conditions, the concentration outside the window of a fifth-floor office is almost the same as for an office on the ground floor

    Vertical Profiles of Pollution Particle Concentrations in the Boundary Layer above Paris (France) from the Optical Aerosol Counter LOAC Onboard a Touristic Balloon

    No full text
    International audienceAtmospheric pollution by particulate matter represents a significant health risk and needs continuous monitoring by air quality networks that provide mass concentrations for PM10 and PM2.5 (particles with diameter smaller than 10 µm and 2.5 µm, respectively). We present here a new approach to monitor the urban particles content, using six years of aerosols number concentration measurements for particles in the 0.2−50 µm size range. These measurements are performed by the Light Optical Aerosols Counter (LOAC) instrument onboard the tethered touristic balloon "Ballon de Paris Generali", in Paris, France. Such measurements have allowed us first to detect at ground a seasonal variability in the particulate matter content, due to the origin of the particles (anthropogenic pollution, pollens), and secondly, to retrieve the mean evolution of particles concentrations with height above ground up to 150 m. Measurements were also conducted up to 300 m above ground during major pollution events. The vertical evolution of concentrations varies from one event to another, depending on the origin of the pollution and on the meteorological conditions. These measurements have shown the interest of performing particle number concentrations measurements for the air pollution monitoring in complement with regulatory mass concentrations measurement, to better evaluate the intensity of the pollution event and to better consider the effect of smallest particles, which are more dangerous for human health

    Ultra-light airborne measurement system for investigation of urban boundary layer dynamics

    Get PDF
    Winter smog episodes are a severe problem in many cities around the world. The following two mechanisms are responsible for influencing the level of pollutant concentrations: emission of pollutants from different sources and associated processes leading to formation of secondary aerosols in the atmosphere and meteorology, including advection, which is stimulated by horizontal wind, and convection, which depends on vertical air mass movements associated with boundary layer stability that are determined by vertical temperature and humidity gradients. The aim of the present study was to evaluate the performance of an unmanned aerial vehicle (UAV)-based measurement system developed for investigation of urban boundary layer dynamics. The evaluation was done by comparing the results of temperature, relative humidity, wind speed and particulate matter fraction with aerodynamic diameter below 10 m (PM10PM_{10}) concentration vertical profiles obtained using this system with two reference meteorological stations: Jagiellonian University Campus (JUC) and radio transmission tower (RTCN), located in the urban area of Krakow city, Southern Poland. The secondary aim of the study was to optimize data processing algorithms improving the response time of UAV sensor measurements during the ascent and descent parts of the flight mission
    corecore