483 research outputs found
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Pulmonary Vascular Tree Segmentation from Contrast-Enhanced CT Images
We present a pulmonary vessel segmentation algorithm, which is fast, fully
automatic and robust. It uses a coarse segmentation of the airway tree and a
left and right lung labeled volume to restrict a vessel enhancement filter,
based on an offset medialness function, to the lungs. We show the application
of our algorithm on contrast-enhanced CT images, where we derive a clinical
parameter to detect pulmonary hypertension (PH) in patients. Results on a
dataset of 24 patients show that quantitative indices derived from the
segmentation are applicable to distinguish patients with and without PH.
Further work-in-progress results are shown on the VESSEL12 challenge dataset,
which is composed of non-contrast-enhanced scans, where we range in the
midfield of participating contestants.Comment: Part of the OAGM/AAPR 2013 proceedings (1304.1876
Tracking and diameter estimation of retinal vessels using Gaussian process and Radon transform
Extraction of blood vessels in retinal images is an important step for computer-aided diagnosis of
ophthalmic pathologies. We propose an approach for blood vessel tracking and diameter estimation. We hypothesize
that the curvature and the diameter of blood vessels are Gaussian processes (GPs). Local Radon transform,
which is robust against noise, is subsequently used to compute the features and train the GPs. By learning
the kernelized covariance matrix from training data, vessel direction and its diameter are estimated. In order to
detect bifurcations, multiple GPs are used and the difference between their corresponding predicted directions is
quantified. The combination of Radon features and GP results in a good performance in the presence of noise.
The proposed method successfully deals with typically difficult cases such as bifurcations and central arterial
reflex, and also tracks thin vessels with high accuracy. Experiments are conducted on the publicly available
DRIVE, STARE, CHASEDB1, and high-resolution fundus databases evaluating sensitivity, specificity, and
Matthew’s correlation coefficient (MCC). Experimental results on these datasets show that the proposed method
reaches an average sensitivity of 75.67%, specificity of 97.46%, and MCC of 72.18% which is comparable to the
state-of-the-art
A novel MRA-based framework for the detection of changes in cerebrovascular blood pressure.
Background: High blood pressure (HBP) affects 75 million adults and is the primary or contributing cause of mortality in 410,000 adults each year in the United States. Chronic HBP leads to cerebrovascular changes and is a significant contributor for strokes, dementia, and cognitive impairment. Non-invasive measurement of changes in cerebral vasculature and blood pressure (BP) may enable physicians to optimally treat HBP patients. This manuscript describes a method to non-invasively quantify changes in cerebral vasculature and BP using Magnetic Resonance Angiography (MRA) imaging.
Methods: MRA images and BP measurements were obtained from patients (n=15, M=8, F=7, Age= 49.2 ± 7.3 years) over a span of 700 days. A novel segmentation algorithm was developed to identify brain vasculature from surrounding tissue. The data was processed to calculate the vascular probability distribution function (PDF); a measure of the vascular diameters in the brain. The initial (day 0) PDF and final (day 700) PDF were used to correlate the changes in cerebral vasculature and BP. Correlation was determined by a mixed effects linear model analysis.
Results: The segmentation algorithm had a 99.9% specificity and 99.7% sensitivity in identifying and delineating cerebral vasculature. The PDFs had a statistically significant correlation to BP changes below the circle of Willis (p-value = 0.0007), but not significant (p-value = 0.53) above the circle of Willis, due to smaller blood vessels.
Conclusion: Changes in cerebral vasculature and pressure can be non-invasively obtained through MRA image analysis, which may be a useful tool for clinicians to optimize medical management of HBP
Segmentation of nerve bundles and ganglia in spine MRI using particle filters
14th International Conference, Toronto, Canada, September 18-22, 2011, Proceedings, Part IIIAutomatic segmentation of spinal nerve bundles that originate within the dural sac and exit the spinal canal is important for diagnosis and surgical planning. The variability in intensity, contrast, shape and direction of nerves seen in high resolution myelographic MR images makes segmentation a challenging task. In this paper, we present an automatic tracking method for nerve segmentation based on particle filters. We develop a novel approach to particle representation and dynamics, based on Bézier splines. Moreover, we introduce a robust image likelihood model that enables delineation of nerve bundles and ganglia from the surrounding anatomical structures. We demonstrate accurate and fast nerve tracking and compare it to expert manual segmentation.National Institutes of Health (U.S.) (NAMIC award U54-EB005149)National Science Foundation (U.S.) (CAREER grant 0642971
Aquatics reconstruction software: the design of a diagnostic tool based on computer vision algorithms
Computer vision methods can be applied to a variety of medical and surgical applications, and many techniques and algorithms are available that can be used to recover 3D shapes and information from images range and volume data. Complex practical applications, however, are rarely approachable with a single technique, and require detailed analysis on how they can be subdivided in subtasks that are computationally treatable and that, at the same time, allow for the appropriate level of user-interaction. In this paper we show an example of a complex application where, following criteria of efficiency, reliability and user friendliness, several computer vision techniques have been selected and customized to build a system able to support diagnosis and endovascular treatment of Abdominal Aortic Aneurysms. The system reconstructs the geometrical representation of four different structures related to the aorta (vessel lumen, thrombus, calcifications and skeleton) from CT angiography data. In this way it supports the three dimensional measurements required for a careful geometrical evaluation of the vessel, that is fundamental to decide if the treatment is necessary and to perform, in this case, its planning. The system has been realized within the European trial AQUATICS (IST-1999-20226 EUTIST-M WP 12), and it has been widely tested on clinical data
3D Frangi-based lung vessel enhancement filter penalizing airways
This paper describes a fully automatic simultaneous lung vessel and airway enhancement filter. The approach consists of a Frangi-based multiscale vessel enhancement filtering specifically designed for lung vessel and airway detection, where arteries and veins have high contrast with respect to the lung parenchyma, and airway walls are hollow tubular structures with a non negative response using the classical Frangi's filter. The features extracted from the Hessian matrix are used to detect centerlines and approximate walls of airways, decreasing the filter response in those areas by applying a penalty function to the vesselness measure. We validate the segmentation method in 20 CT scans with different pathological states within the VESSEL12 challenge framework. Results indicate that our approach obtains good results, decreasing the number of false positives in airway walls
- …