5 research outputs found

    Shape variation analyzer: A classifier for temporomandibular joint damaged by osteoarthritis

    Get PDF
    We developed a deep learning neural network, the Shape Variation Analyzer (SVA), that allows disease staging of bony changes in temporomandibular joint (TMJ) osteoarthritis (OA). The sample was composed of 259 TMJ CBCT scans for the training set and 34 for the testing dataset. The 3D meshes had been previously classified in 6 groups by 2 expert clinicians. We improved the robustness of the training data using data augmentation, SMOTE, to alleviate over-fitting and to balance classes. We combined geometrical features and a shape descriptor, heat kernel signature, to describe every shape. The results were compared to nine different supervised machine learning algorithms. The deep learning neural network was the most accurate for classification of TMJ OA. In conclusion, SVA is a 3D Slicer extension that classifies pathology of the temporomandibular joint osteoarthritis cases based on 3D morphology

    Osteoarthritis of the Temporomandibular Joint can be diagnosed earlier using biomarkers and machine learning

    Get PDF
    After chronic low back pain, Temporomandibular Joint (TMJ) disorders are the second most common musculoskeletal condition affecting 5 to 12% of the population, with an annual health cost estimated at $4 billion. Chronic disability in TMJ osteoarthritis (OA) increases with aging, and the main goal is to diagnosis before morphological degeneration occurs. Here, we address this challenge using advanced data science to capture, process and analyze 52 clinical, biological and high-resolution CBCT (radiomics) markers from TMJ OA patients and controls. We tested the diagnostic performance of four machine learning models: Logistic Regression, Random Forest, LightGBM, XGBoost. Headaches, Range of mouth opening without pain, Energy, Haralick Correlation, Entropy and interactions of TGF-β1 in Saliva and Headaches, VE-cadherin in Serum and Angiogenin in Saliva, VE-cadherin in Saliva and Headaches, PA1 in Saliva and Headaches, PA1 in Saliva and Range of mouth opening without pain; Gender and Muscle Soreness; Short Run Low Grey Level Emphasis and Headaches, Inverse Difference Moment and Trabecular Separation accurately diagnose early stages of this clinical condition. Our results show the XGBoost + LightGBM model with these features and interactions achieves the accuracy of 0.823, AUC 0.870, and F1-score 0.823 to diagnose the TMJ OA status. Thus, we expect to boost future studies into osteoarthritis patient-specific therapeutic interventions, and thereby improve the health of articular joints

    High-Resolution Quantitative Cone-Beam Computed Tomography: Systems, Modeling, and Analysis for Improved Musculoskeletal Imaging

    Get PDF
    This dissertation applies accurate models of imaging physics, new high-resolution imaging hardware, and novel image analysis techniques to benefit quantitative applications of x-ray CT in in vivo assessment of bone health. We pursue three Aims: 1. Characterization of macroscopic joint space morphology, 2. Estimation of bone mineral density (BMD), and 3. Visualization of bone microstructure. This work contributes to the development of extremity cone-beam CT (CBCT), a compact system for musculoskeletal (MSK) imaging. Joint space morphology is characterized by a model which draws an analogy between the bones of a joint and the plates of a capacitor. Virtual electric field lines connecting the two surfaces of the joint are computed as a surrogate measure of joint space width, creating a rich, non-degenerate, adaptive map of the joint space. We showed that by using such maps, a classifier can outperform radiologist measurements at identifying osteoarthritic patients in a set of CBCT scans. Quantitative BMD accuracy is achieved by combining a polyenergetic model-based iterative reconstruction (MBIR) method with fast Monte Carlo (MC) scatter estimation. On a benchtop system emulating extremity CBCT, we validated BMD accuracy and reproducibility via a series of phantom studies involving inserts of known mineral concentrations and a cadaver specimen. High-resolution imaging is achieved using a complementary metal-oxide semiconductor (CMOS)-based x-ray detector featuring small pixel size and low readout noise. A cascaded systems model was used to performed task-based optimization to determine optimal detector scintillator thickness in nominal extremity CBCT imaging conditions. We validated the performance of a prototype scanner incorporating our optimization result. Strong correlation was found between bone microstructure metrics obtained from the prototype scanner and µCT gold standard for trabecular bone samples from a cadaver ulna. Additionally, we devised a multiresolution reconstruction scheme allowing fast MBIR to be applied to large, high-resolution projection data. To model the full scanned volume in the reconstruction forward model, regions outside a finely sampled region-of-interest (ROI) are downsampled, reducing runtime and cutting memory requirements while maintaining image quality in the ROI

    Validation of CBCT for the computation of textural biomarkers

    No full text
    corecore