236 research outputs found

    Prediction of oxygen uptake (VO2) using neural networks

    Get PDF
    This thesis focuses on using neural network models for the prediction of oxygen uptake (VO2). The predictions are made using regression techniques. The dataset contains independent predictor variables such as heart rate (HR), energy expenditure (EE), height, body mass, gender and age. VO2 is the output dependent variable. The goal is to evaluate and compare the performance of neural networks to other machine learning techniques such as support vector machines and multiple linear regression. Few neural network models have been tested previously in the literature for maximal oxygen uptake (VO2max) prediction. During the last decade, most approaches have focused on support vector machines and linear regression equations. In this thesis, data collected at the University of JyvĂ€skylĂ€ is used to create a dataset for the prediction of VO2. A detailed statistical analysis has been performed to see the relationship between speed, VO2 and energy expenditure. Using 8 different combinations of predictor variables, neural network’s performance and the effect of predictor variables on the performance is measured. Data pre-processing is performed. R2 value and root mean square error value is used for measuring the performance of the machine learning models. Same data set is used for all models to ensure accurate results. The results of this thesis show that speed, VO2 and energy expenditure have a direct relationship. Males show higher energy produced as compared to females. The neural network model outperformed support vector machine and multiple linear regression by resulting in accurate predictions, high R2 value and low root mean square value. The highest accuracy is achieved with the model containing all predictor variables. The inclusion of HR as a predictor variable is important due to its effect on the performance of the model. Further advancements in neural networks can allow more accurate VO2 predictions, the model can also be used in a wearable device for real-time VO2 prediction. The same approach can be extended to predict VO2max values

    A mathematical model for predicting HR max, VO2 max, and oxygen uptake kinetics during treadmill walking and running at varied intensities

    Get PDF
    Maximal oxygen uptake (VO2 max) is difficult to measure and most predictions are inaccurate due to a variety of assumptions. The purpose of this study was to validate a dynamical system model (DSM) for predicting HR max and VO2 max during walking and running. A secondary purpose was to predict VO2 responses using a neural network. Twenty-six healthy males completed a maximal cardiopulmonary exercise test (CPET) and a submaximal protocol. The models were applied to the submaximal data to estimate the participants’ HR/VO2 responses and predict their HR max and VO2 max. The model accurately tracked HR and VO2 responses (R2 = -.85-0.99). However, it did not accurately estimate max (R2 < 0). Further refinement of the model is needed. This study elucidated some of the challenges of using a DSM and demonstrated that a neural network may be useful for easily predicting VO2 responses.Master of Art

    Techniques Based on Adaptive Neuro-Fuzzy Inference Systems (ANFIS) for Estimating and Evaluating Physical Demands at Work Using Heart Rate

    Get PDF
    RÉSUMÉ : MalgrĂ© l'Ă©volution rapide de la mĂ©canisation dans les industries lourdes, les emplois physiquement exigeants qui nĂ©cessitent un effort humain excessif reprĂ©sentent encore une part importante dans de nombreuses industries (foresterie, construction, mines, etc.). Des Ă©tudes ont montrĂ© que les charges de travail excessives imposĂ©es aux travailleurs sont la principale cause de fatigue physique, ce qui a des effets nĂ©gatifs sur les travailleurs, leur performance et la qualitĂ© du travail. Par consĂ©quent, les chercheurs ont soulignĂ© l'importance de la conception optimale des tĂąches (Ă  l'intĂ©rieur des compĂ©tences des travailleurs) afin de maintenir la sĂ©curitĂ©, la santĂ© et la productivitĂ© des travailleurs. Toutefois, cela ne peut ĂȘtre atteint sans comprendre (c'est-Ă -dire mesurer et Ă©valuer) les exigences physiologiques du travail. À cet Ă©gard, les trois Ă©tudes comprises dans cette thĂšse prĂ©sentent des approches pratiques pour estimer et Ă©valuer la dĂ©pense Ă©nergĂ©tique (DE), exprimĂ©e en termes de consommation d'oxygĂšne (VO2), au cours du travail rĂ©el. La premiĂšre Ă©tude prĂ©sente de nouvelles approches basĂ©es sur le systĂšme d'infĂ©rence neuro-flou adaptatif (ANFIS) pour l'estimation de la VO2 Ă  partir des mesures de la frĂ©quence cardiaque (FC). Cette Ă©tude comprend deux Ă©tapes auxquelles ont participĂ© 35 individus en bonne santĂ©. Dans un premier temps, deux modĂšles novateurs individuels ont Ă©tĂ© dĂ©veloppĂ©s en se basant sur l’ANFIS et les mĂ©thodes analytiques. Ces modĂšles s'attaquent au problĂšme de l'incertitude et de la non-linĂ©aritĂ© entre la FC et la VO2. Dans un deuxiĂšme temps, un modĂšle gĂ©nĂ©ral ANFIS qui ne requiert pas d'Ă©talonnage individuel a Ă©tĂ© dĂ©veloppĂ©. Les trois modĂšles ont Ă©tĂ© testĂ©s en laboratoire et sur le terrain. La performance de chaque modĂšle a Ă©tĂ© Ă©valuĂ©e et comparĂ©e aux VO2 mesurĂ©es et Ă  deux mĂ©thodes d'estimation individuelles et traditionnelles de VO2 (Ă©talonnage linĂ©aire et Flex-HR). Les rĂ©sultats ont indiquĂ© la prĂ©cision supĂ©rieure obtenue avec la modĂ©lisation ANFIS individualisĂ©e (EMQ = 1,0 Ă  2,8 ml/kg.min en laboratoire et sur le terrain, respectivement). Le modĂšle analytique a surpassĂ© l'Ă©talonnage linĂ©aire traditionnel et les mĂ©thodes Flex-HR avec des donnĂ©es terrain. Les estimations du modĂšle gĂ©nĂ©ral ANFIS de la VO2 ne diffĂ©raient pas significativement des mesures rĂ©elles terrain VO2 (EMQ = 3,5 ml/kg.min). Avec sa facilitĂ© d'utilisation et son faible coĂ»t de mise en Ɠuvre, le modĂšle gĂ©nĂ©ral ANFIS montre du potentiel pour remplacer n'importe laquelle des mĂ©thodes traditionnelles individualisĂ©es pour l’estimation de la VO2 Ă  partir de donnĂ©es recueillies sur le terrain. La deuxiĂšme Ă©tude prĂ©sente un modĂšle de prĂ©diction de la VO2 basĂ© sur ANFIS qui est inspirĂ© de la mĂ©thode Flex-HR. Des Ă©tudes ont montrĂ© que la mĂ©thode Flex-HR est une des mĂ©thodes les plus prĂ©cises pour l'estimation de la VO2. Toutefois, cette mĂ©thode est basĂ©e sur quatre paramĂštres qui sont dĂ©terminĂ©s individuellement et par consĂ©quent ceci est considĂ©rĂ© comme coĂ»teux, chronophage et souvent peu pratique, surtout lorsque le nombre de travailleurs augmente. Le modĂšle prĂ©dictif proposĂ© se compose de trois modules ANFIS pour estimer les paramĂštres de Flex-HR. Pour chaque module ANFIS, la sĂ©lection de variables d'entrĂ©e et le modĂšle d'Ă©valuation ont Ă©tĂ© simultanĂ©ment rĂ©alisĂ©s Ă  l'aide de la combinaison de la technique de division des donnĂ©es en trois parties et la technique de validation croisĂ©e. La performance de chaque module ANFIS a Ă©tĂ© testĂ©e et comparĂ©e avec les paramĂštres observĂ©s ainsi qu'avec les modĂšles de Rennie et coll. (2001) Ă  l'aide de donnĂ©es de test indĂ©pendant. En outre, les performances du modĂšle global de prĂ©diction ANFIS dans l'estimation de la VO2 a Ă©tĂ© testĂ© et comparĂ© avec les valeurs mesurĂ©es de la VO2, la mĂ©thode de Flex-HR standard ainsi qu'avec les autres modĂšles gĂ©nĂ©raux (c.-Ă -d., les modĂšles de Rennie et coll. (2001) et de Keytel et coll. (2005)). Les rĂ©sultats n'ont indiquĂ© aucune diffĂ©rence significative entre les paramĂštres observĂ©s et estimĂ©s de Flex-HR et entre la VO2 mesurĂ©e et estimĂ©e dans la plage de frĂ©quence cardiaque globale et sĂ©parĂ©ment dans diffĂ©rentes gammes de FC. Le modĂšle de prĂ©diction ANFIS (EMA = 3 ml/kg.min) a montrĂ© de meilleures performances que les modĂšles de Rennie et coll. (EMA = 7 ml/kg.min) et les modĂšles de Keytel et coll. (EMA = 6 ml/kg.min) et des performances comparables avec la mĂ©thode standard de Flex-HR (EMA = 2,3 ml/kg.min) tout au long de la plage de frĂ©quence cardiaque. Le modĂšle ANFIS fournit ainsi aux praticiens une mĂ©thode pratique, Ă©conomique et rapide pour l'estimation de la VO2 sans besoin d'Ă©talonnage individuel. La troisiĂšme Ă©tude prĂ©sente une nouvelle approche basĂ©e sur l'ANFIS pour classer les travaux en quatre classes d'intensitĂ© (c'est-Ă -dire, trĂšs lĂ©ger, lĂ©ger, modĂ©rĂ© et lourd) Ă  l'aide du monitorage du rythme cardiaque. La variabilitĂ© intra-individuelle (diffĂ©rences physiologiques et physiques) a Ă©tĂ© examinĂ©e. Vingt-huit participants ont effectuĂ© le test de la montĂ©e des marches Meyer et Flenghi (1995) et le test maximal sur le tapis roulant pendant lesquels la frĂ©quence cardiaque et la consommation d'oxygĂšne ont Ă©tĂ© mesurĂ©es. Les rĂ©sultats ont indiquĂ© que le monitorage du rythme cardiaque (FC, FC max et FC repos) et du poids corporel sont des variables significatives pour classer le rythme de travail. Le classificateur ANFIS a montrĂ© une sensibilitĂ©, une spĂ©cificitĂ© et une exactitude supĂ©rieures par rapport Ă  la pratique courante Ă  l'aide de catĂ©gories de rythme de travail basĂ©es sur le pourcentage de frĂ©quence cardiaque de rĂ©serve (% FCR), avec une diffĂ©rence globale de 29,6 % dans la prĂ©cision de classification entre les deux mĂ©thodes et un bon Ă©quilibre entre la sensibilitĂ© (90,7 %, en moyenne) et la spĂ©cificitĂ© (95,2 %, en moyenne). Avec sa facilitĂ© de mise en Ɠuvre et sa mesure variable, le classificateur ANFIS montre un potentiel pour une utilisation gĂ©nĂ©ralisĂ©e par les praticiens pour Ă©valuation du rythme de travail.----------ABSTRACT : Despite the rapid evolution of mechanization in heavy industries, physically demanding jobs that require excessive human effort still represent a significant part of many industries (e.g., forestry, construction, mining etc.). Studies have shown that excessive workloads placed on workers are the main cause of physical fatigue, which has negative effects on the workers, their performance and quality of work. Therefore, researchers have emphasized on the importance of the optimal job design (within workers’ capacity) in order to maintain workers’ safety, health and productivity. However, this cannot be achieved without understanding (i.e., measuring and evaluating) the physiological demands of work. In this respect, the three studies comprising this dissertation present practical approaches for estimating and evaluating energy expenditure (EE), expressed in terms of oxygen consumption (VO2), during actual work. The first study presents new approaches based on adaptive neuro-fuzzy inference system (ANFIS) for the estimation of VO2 from heart rate (HR) measurements. This study comprises two stages in which 35 healthy individuals participated. In the first stage, two novel individual models were developed based on the ANFIS and the analytical methods. These models tackle the problem of uncertainty and nonlinearity between HR and VO2. In the second stage, a General ANFIS model was developed which does not require individual calibration. The three models were tested under laboratory and field conditions. Performance of each model was evaluated and compared to the measured VO2 and two traditional individual VO2 estimation methods (linear calibration and Flex-HR). Results indicated the superior precision achieved with individualized ANFIS modeling (RMSE= 1.0 and 2.8 ml/kg.min in laboratory and field, respectively). The analytical model outperformed the traditional linear calibration and Flex-HR methods with field data. The General ANFIS model’s estimates of VO2 were not significantly different from actual field VO2 measurements (RMSE= 3.5 ml/kg.min). With its ease of use and low implementation cost, the General ANFIS model shows potential to replace any of the traditional individualized methods for VO2 estimation from HR data collected in the field. The second study presents an ANFIS-based VO2 prediction model that is inspired by the Flex-HR method. Studies have shown that the Flex-HR method is one of the most accurate methods for VO2 estimation. However, this method is based on four parameters that are determined individually and therefore it is considered costly, time consuming and often impractical, especially when the number of workers increases. The proposed prediction model consists of three ANFIS modules for estimating the Flex-HR parameters. For each ANFIS module, input variables selection and model assessment were simultaneously performed using the combination of three-way data split and cross-validation techniques. The performance of each ANFIS module was tested and compared with the observed parameters as well as with Rennie et al.’s (2001) models using independent test data. In addition, the performance of the overall ANFIS prediction model in estimating VO2 was tested and compared with the measured VO2 values, the standard Flex-HR method as well as with other general models (i.e., Rennie et al.’s (2001) and Keytel et al.’s (2005) models). Results indicated no significant difference between observed and estimated Flex-HR parameters and between measured and estimated VO2 in the overall HR range, and separately in different HR ranges. The ANFIS prediction model (MAE = 3 ml/kg.min) demonstrated better performance than Rennie et al.’s (MAE = 7 ml/kg.min) and Keytel et al.’s (MAE = 6 ml/kg.min) models, and comparable performance with the standard Flex-HR method (MAE = 2.3 ml/kg.min) throughout the HR range. The ANFIS model thus provides practitioners with a practical, cost- and time-efficient method for VO2 estimation without the need for individual calibration. The third study presents a new approach based ANFIS for classifying work intensity into four classes (i.e., very light, light, moderate and heavy) by using heart rate monitoring. Intersubject variability (physiological and physical differences) was considered. Twenty-eight participants performed Meyer and Flenghi (1995) step-test and a maximal treadmill test, during which heart rate and oxygen consumption were measured. Results indicated that heart rate monitoring (HR, HRmax, and HRrest) and body weight are significant variables for classifying work rate. The ANFIS classifier showed superior sensitivity, specificity, and accuracy compared to current practice using established work rate categories based on percent heart rate reserve (%HRR), with an overall 29.6% difference in classification accuracy between the two methods, and good balance between sensitivity (90.7%, on average) and specificity (95.2%, on average). With its ease of implementation and variable measurement, the ANFIS classifier shows potential for widespread use by practitioners for work rate assessment

    Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta‑analysis and Expert Statement of the INTERLIVE Network

    Get PDF
    This research was partly funded by Huawei Technologies Oy (Finland) Co. Ltd. A limited liability company headquartered in Helsinki, Finland.Background Technological advances have recently made possible the estimation of maximal oxygen consumption (VO2max) by consumer wearables. However, the validity of such estimations has not been systematically summarized using metaanalytic methods and there are no standards guiding the validation protocols. Objective The aim was to (1) quantitatively summarize previous studies investigating the validity of the VO2max estimated by consumer wearables and (2) provide best-practice recommendations for future validation studies. Methods First, we conducted a systematic review and meta-analysis of studies validating the estimation of VO2max by wearables. Second, based on the state of knowledge (derived from the systematic review) combined with the expert discussion between the members of the Towards Intelligent Health and Well-Being Network of Physical Activity Assessment (INTERLIVE) consortium, we provided a set of best-practice recommendations for validation protocols. Results Fourteen validation studies were included in the systematic review and meta-analysis. Meta-analysis results revealed that wearables using resting condition information in their algorithms significantly overestimated VO2max (bias 2.17 ml·kg−1·min−1; limits of agreement − 13.07 to 17.41 ml·kg−1·min−1), while devices using exercise-based information in their algorithms showed a lower systematic and random error (bias − 0.09 ml·kg−1·min−1; limits of agreement − 9.92 to 9.74 ml·kg−1·min−1). The INTERLIVE consortium proposed six key domains to be considered for validating wearable devices estimating VO2max, concerning the following: the target population, reference standard, index measure, testing conditions, data processing, and statistical analysis. Conclusions Our meta-analysis suggests that the estimations of VO2max by wearables that use exercise-based algorithms provide higher accuracy than those based on resting conditions. The exercise-based estimation seems to be optimal for measuring VO2max at the population level, yet the estimation error at the individual level is large, and, therefore, for sport/ clinical purposes these methods still need improvement. The INTERLIVE network hereby provides best-practice recommendations to be used in future protocols to move towards a more accurate, transparent and comparable validation of VO2max derived from wearables.Huawei Technologie

    A framework for intelligent inventory prediction in small and medium- scale enterprise.

    Get PDF
    The aim of this research is to apply an intelligent technique to predict optimal inventory quantity in small and medium-scale enterprise. This is in view of the fact that the conventional models such as the EOQ model use only deterministic while some decision variables are non-deterministic in nature. Forecasted average demand of items for ten months in a small-scale retail outlet was collected and trained using an Artificial Neural Networks (ANN) of 5 neurons in the input layer with eight neurons in the first hidden layer and four neurons in the second hidden layer. Two feed-forward training algorithms of quasi-newton and quick propagation were employed in the training with the results of fuzzy logic technology found in the literature as the target output. Results obtained show that the quasi-newton algorithm covaries stronger with the fuzzy logic results than the quick propagation results. The objective and subjective feelings of the inventory manager were also captured to optimise the results of the training. The study is at a framework stage and will proceed to implementation level when more datasets are collected. Data collection in a small-scale outlet is a daunting task as record keeping is hardly done. The inclusion of non-deterministic circumstances such as emotional and objective feelings of the inventory manager to predict inventory is novel considering the fact that studies in the available intelligent inventory prediction have not employed such variables in their predictions

    A Framework for Intelligent Inventory Prediction in Small and Medium- Scale Enterprise

    Get PDF
    The aim of this research is to apply an intelligent technique to predict optimal inventory quantity in small and medium-scale enterprise. This is in view of the fact that the conventional models such as the EOQ model use only deterministic while some decision variables are non- deterministic in nature. Forecasted average demand of items for ten months in a small-scale retail outlet was collected and trained using an Artificial Neural Networks (ANN) of 5 neurons in the input layer with eight neurons in the first hidden layer and four neurons in the second hidden layer. Two feed-forward training algorithms of quasi-newton and quick propagation were employed in the training with the results of fuzzy logic technology found in the literature as the target output. Results obtained show that the quasi-newton algorithm covaries stronger with the fuzzy logic results than the quick propagation results. The objective and subjective feelings of the inventory manager were also captured to optimise the results of the training. The study is at a framework stage and will proceed to implementation level when more datasets are collected. Data collection in a small-scale outlet is a daunting task as record keeping is hardly done. The inclusion of non-deterministic circumstances such as emotional and objective feelings of the inventory manager to predict inventory is novel considering the fact that studies in the available intelligent inventory prediction have not employed such variables in their predictions. Keywords: Artificial Neural networks, Fuzzy logic, Quasi newton, Quick propagation, EOQ, Inventory, Forecast. DOI: 10.7176/EJBM/13-2-03 Publication date: January 31st 202

    Accuracy of the Polar M52 heart rate monitor for estimating energy expenditure, substrate utilization, and maximal oxygen uptake

    Get PDF
    The purpose of this study was to test the accuracy of the Polar M52 heart rate monitor

    Prediction and structure of triathlon performance in recreational and elite triathletes

    Get PDF
    Die Sportart Triathlon kombiniert die drei Ausdauersportarten Schwimmen, Radfahren und Laufen, die nacheinander ohne Pause ausgefĂŒhrt werden und in eine Gesamtwettkampfzeit mĂŒnden. Die Olympische Distanz ĂŒber 1.5 km Schwimmen, 40 km Radfahren und 10 km Laufen stellt die am meisten verbreitete Wettkampfdistanz dar, sowohl im Amateur- als auch im Profi-Bereich. Als Ausdauer determinierte Sportart erfordert Triathlon, wie auch die drei Einzeldisziplinen, spezifische physiologische Anforderungen. Zahlreiche weitere Bereiche wie die Anthropometrie der Athletinnen und Athleten, psychologische Voraussetzungen und vieles mehr können ebenfalls leistungsdeterminierend sein. Es ist davon auszugehen, dass selbst die einzelnen StreckenlĂ€ngen im Triathlon – neben der Olympischen Distanz existieren noch die kĂŒrzere Sprint- sowie die lĂ€ngere Halb- und Langdistanz – jeweils spezifische Charakteristika mit sich bringen, die durch eine angepasste Vorbereitung und Trainingsgestaltung vorbereitet werden können. Die Bestimmung solch leistungsrelevanter Parameter einer Sportart oder einer sportlichen Leistung werden im Bereich der Trainingswissenschaft als Struktur der sportlichen Leistung zusammengefasst und bilden die Grundlage fĂŒr wissenschaftlich fundierte Aussagen zur Trainingsgestaltung, Talentauswahl und vielem mehr. Eng damit verbunden ist die Prognose sportlicher Leistung, die auf Basis der identifizierten Parameter und deren Quantifizierung mittels einer aktuellen leistungsdiagnostischen Untersuchung eine Prognose der tatsĂ€chlichen Wettkampfleistung bspw. in Form einer Gesamtwettkampfzeit ermöglichen kann. Die VerknĂŒpfung dieser beiden Aspekte – die Prognose und die Struktur der sportlichen Leistung in der Sportart Triathlon – bilden den Kern der vorliegenden Dissertation, wobei sowohl Amateur- als auch Profi-Sportler in den Fokus genommen wurden. Die Dissertation umfasst acht Kapitel. Nach einem kurzen Vorwort und einer allgemeinen EinfĂŒhrung in die Thematik (Kapitel 1) liefert Kapitel 2 den theoretischen und methodischen Hintergrund. Insbesondere werden die Besonderheiten, Rahmenbedingungen und Voraussetzungen der Sportart Triathlon, der aktuelle Forschungsstand in den Bereichen der Prognose und Struktur sportlicher Leistung sowie die in dieser Thesis verwendeten methodischen AnsĂ€tze nĂ€her beleuchtet. Da der Einsatz unterschiedlicher Methoden ein wichtiger Bestandteil dieser Arbeit darstellt wird deren Einsatz in den drei Studien (Kapitel 4 bis 6) ausfĂŒhrlicher vorbereitet: die explorative Faktorenanalyse und der Dominanz-Paar-Vergleich als Verfahren zur Vorselektion leistungsrelevanter Parameter, die multiple lineare Regression und kĂŒnstliche neuronale Netze zur Prognose der individuellen Gesamtwettkampfzeit sowie die Strukturgleichungsanalyse als Verfahren zur Berechnung eines Strukturgleichungsmodells der sportlichen Leistung im Triathlon. Nach der Ableitung der Fragestellungen und der Darstellung der Ziele der vorliegenden Thesis (Kapitel 3), liefern die Forschungsarbeiten in den drei darauffolgenden Kapiteln ErklĂ€rungsansĂ€tze hierzu. Die Studie in Kapitel 4 liefert erste Erkenntnisse und weist Leistungsparameter nach, die zur Prognose der individuellen Wettkampfleistung von Amateur-Triathleten ĂŒber die Sprintdistanz dienen. Hierbei wurden anthropometrische, physiologische und trainingsbezogene Parameter im Rahmen einer Leistungsdiagnostik unter Laborbedingungen unmittelbar vor einem Triathlon Wettkampf erfasst und statistische ZusammenhĂ€nge zur erbrachten Wettkampfleistung hergestellt. Drei Modelle zur Prognose der Wettkampfleistung konnten mittels linearer Regression berechnet und dabei leistungsrelevante Parameter identifiziert werden. Das auf dem physiologischen Parameter Blutlaktatkonzentration nach 18 min bei 200 W auf einem Fahrradergometer aufbauende Prognosemodel liefert die höchste VarianzaufklĂ€rung (RÂČ = 0.71), gefolgt von den Modellen basierend auf den anthropometrischen Parametern BeinlĂ€nge und Armspannweite (RÂČ = 0.67) und dem trainingsbezogenen Parameter Trainingsumfang im Schwimmen (RÂČ = 0.41). Nachgewiesen werden konnte, dass dies selbst bei kleinen Stichproben möglich ist und Hinweise zur Trainingsgestaltung und zur Wettkampfeinteilung liefern kann, insbesondere im Amateur-Bereich jedoch mit einer stark eingeschrĂ€nkten Generalisierbarkeit verbunden sein dĂŒrfte. Eine Herausforderung bei grĂ¶ĂŸeren Studien dĂŒrfte daher die vergleichbare Erfassung der Gesamtwettkampfzeit als abhĂ€ngige Variable darstellen. Die Studie in Kapitel 5 untersucht auf Basis der vorangegangenen Erfahrungen die Prognose der Gesamtwettkampfzeit von Profi-Triathleten ĂŒber die olympische Distanz. Hierbei wurden die routinemĂ€ĂŸig durchgefĂŒhrten leistungsdiagnostischen Untersuchungen von Triathleten, die in der Vorbereitung auf die olympischen Sommerspiele im Jahr 2012 durch das Institut fĂŒr Angewandte Trainingswissenschaft in Leipzig getestet wurden, analysiert und fĂŒr die Berechnungen der Prognosemodelle verwendet. Dem hohen Maß an Standardisierung der Testungen mit einer großen Anzahl an erfassten Parametern stand die Notwendigkeit der Normalisierung der Gesamtwettkampfzeiten gegenĂŒber. Dies war notwendig, da die Profi-Triathleten an unterschiedlichen WettkĂ€mpfen teilgenommen hatten, zwar ĂŒberwiegend ĂŒber dieselbe StreckenlĂ€nge jedoch mit unterschiedlichsten Streckenprofilen, Teilnehmerfeldern, klimatischen Bedingungen, etc. Im Vergleich zur bisherigen Literatur konnten mit zwei unterschiedlichen AnsĂ€tzen – multiple Regressionen fĂŒr lineare und kĂŒnstliche neuronale Netze fĂŒr nichtlineare ZusammenhĂ€nge zwischen Parametern und Gesamtwettkampfzeit – gute Ergebnisse fĂŒr Prognosemodelle auf Basis anthropometrischer und physiologischer Parameter erzielt werden. Beide AnsĂ€tze lieferten je zwei Prognosemodelle. Die lineare Regression fĂŒhrt zu RÂČ = 0.41 auf Basis anthropometrischer Parameter (prĂ€diktiv: Beckenbreite und Schulterbreite) und zu RÂČ = 0.67 auf Basis physiologischer Parameter (prĂ€diktiv: maximale Atemfrequenz, Laufgeschwindigkeit bei 3-mmol·L-1 Blutlaktatkonzentration und maximale Blutlaktatkonzentration). Basierend auf den jeweils fĂŒnf relevantesten Parametern einer Vorselektion fĂŒhren kĂŒnstliche neuronale Netze zu RÂČ = 0.43 auf Basis anthropometrischer Parameter und RÂČ = 0.86 auf Basis physiologischer Parameter. Der Vorteil neuronaler Netze gegenĂŒber der linearen Regression liegt dabei in der Möglichkeit nichtlineare ZusammenhĂ€nge abzubilden. Im Gegensatz zur durchgefĂŒhrten Studie mit Amateur-Triathleten stellen die Profi-Triathleten eine sehr homogene Stichprobe dar, die der Grundgesamtheit des deutschen Nationalkaders sehr nahekommt, weshalb die Ergebnisse und insbesondere die identifizierten Leistungsparameter eine höhere Generalisierbarkeit aufweisen, wenn auch fĂŒr einen sehr kleinen Kreis an Athleten. Insbesondere zur Ableitung von wichtigen Merkmalen fĂŒr Athletinnen und Athleten in Nachwuchskadern liefern die Ergebnisse wertvolle Hinweise auf potentiell relevante anthropometrische Voraussetzungen sowie auf leistungsrelevante und durch Training beeinflussbare physiologische Parameter. Die dritte Studie (Kapitel 6) nutzt die Ergebnisse der erstellten Prognosemodelle aus Kapitel 5, um trotz des Vorhandenseins einer kleinen Stichprobe ein Strukturmodell der sportlichen Leistung im Triathlon ĂŒber die olympische Distanz zu entwickeln. Hierbei konnten schlussendlich drei gĂŒltige Modelle erstellt werden, die einen ersten wichtigen Schritt zur wissenschaftlich fundierten AufklĂ€rung der Leistungsstruktur im olympischen Triathlon liefern. Insbesondere das Modell, das die Erfahrung von professionellen Trainern in der Vorauswahl an Parametern nutzt, liefert als gut einzustufende Modellparameter, die im Einklang zu den Erkenntnissen der zuvor erstellten Prognosemodelle und des Strukturmodels basierend auf theoretischen Überlegungen und einschlĂ€giger Literatur stehen. Als relevant einzustufende Parameter sind hier sowohl anthropometrische (Körpergewicht, BMI, fettfreie Körpermasse) als auch physiologische (relative maximale Sauerstoffaufnahme, Laufgeschwindigkeit bei 3-mmol/l Blutlaktatkonzentration, maximale Laufgeschwindigkeit in einem spezifischen Mobilisationstest) KenngrĂ¶ĂŸen zu nennen. Als Limitation ist der Einsatz einer kleinen Stichprobe zu nennen, da dies bei der Berechnung von Strukturmodellen von Nachteil sein kann, bei der Verwendung von Daten von Profi-Athleten jedoch unvermeidbar ist. Die entwickelten Modelle sind aus mathematisch-statistischer Sicht eindeutig bestimmt, mĂŒssen jedoch durch weitere DatensĂ€tze ergĂ€nzt werden, um umfassendere Modelle zu ermöglichen. Kapitel 7 liefert schließlich eine allgemeine Diskussion der Forschungsergebnisse und einen Ausblick auf zukĂŒnftige Studien. Die Befunde der drei durchgefĂŒhrten Studien werden zusammengefĂŒhrt und mit dem bisherigen Wissensstand abgeglichen, um eine umfassendere Betrachtung leistungsrelevanter Parameter der Sportart Triathlon sowie der eingesetzten methodischen AnsĂ€tze der multiplen Regression, kĂŒnstlicher neuronaler Netze sowie der Strukturanalyse vorzunehmen. Die vorliegende Dissertation liefert im Wesentlichen sowohl in der Fachliteratur bereits als leistungsrelevant identifizierte Parameter aber auch bisher weniger betrachtete jedoch als potentiell relevant einzustufende Leistungsparameter. Als wesentliches Ergebnis der Dissertation muss der Einsatz der angewendeten Methoden im Kontext der trainingswissenschaftlichen Leistungsdiagnostik gesehen werden, da dies bisher wenig verbreitet ist. Wissend um die EinschrĂ€nkung kleiner Stichproben, welche im Profi-Bereich unvermeidbar sind, werden die möglichen Potentiale fĂŒr zukĂŒnftige Studien deutlich und zeigen somit ein spannendes und bedeutsames zukĂŒnftiges Forschungsfeld und Implikationen fĂŒr sich anschließende Studien auf. Die Dissertation schließt mit einer allgemeinen Zusammenfassung (Kapitel 8) der vorliegenden Arbeit
    • 

    corecore