1,635 research outputs found

    Magnetic and radar sensing for multimodal remote health monitoring

    Get PDF
    With the increased life expectancy and rise in health conditions related to aging, there is a need for new technologies that can routinely monitor vulnerable people, identify their daily pattern of activities and any anomaly or critical events such as falls. This paper aims to evaluate magnetic and radar sensors as suitable technologies for remote health monitoring purpose, both individually and fusing their information. After experiments and collecting data from 20 volunteers, numerical features has been extracted in both time and frequency domains. In order to analyse and verify the validation of fusion method for different classifiers, a Support Vector Machine with a quadratic kernel, and an Artificial Neural Network with one and multiple hidden layers have been implemented. Furthermore, for both classifiers, feature selection has been performed to obtain salient features. Using this technique along with fusion, both classifiers can detect 10 different activities with an accuracy rate of approximately 96%. In cases where the user is unknown to the classifier, an accuracy of approximately 92% is maintained

    Detection of postural transitions using machine learning

    Get PDF
    The purpose of this project is to study the nature of human activity recognition and prepare a dataset from volunteers doing various activities which can be used for constructing the various parts of a machine learning model which is used to identify each volunteers posture transitions accurately. This report presents the problem definition, equipment used, previous work in this area of human activity recognition and the resolution of the problem along with results. Also this report sheds light on the process and the steps taken to undertake this endeavour of human activity recognition such as building of a dataset, pre-processing the data by applying filters and various windowing length techniques, splitting the data into training and testing data, performance of feature selection and feature extraction and finally selecting the model for training and testing which provides maximum accuracy and least misclassification rates. The tools used for this project includes a laptop equipped with MATLAB and EXCEL and MEDIA PLAYER CLASSIC respectively which have been used for data processing, model training and feature selection and Labelling respectively. The data has been collected using an Inertial Measurement Unit contains 3 tri-axial Accelerometers, 1 Gyroscope, 1 Magnetometer and 1 Pressure sensor. For this project only the Accelerometers, Gyroscope and the Pressure sensor is used. The sensor is made by the members of the lab named ‘The Technical Research Centre for Dependency Care and Autonomous Living (CETpD) at the UPC-ETSEIB campus. The results obtained have been satisfactory, and the objectives set have been fulfilled. There is room for possible improvements through expanding the scope of the project such as detection of chronic disorders or providing posture based statistics to the end user or even just achieving a higher rate of sensitivity of transitions of posture by using better features and increasing the dataset size by increasing the number of volunteers.Incomin

    Human activity recognition making use of long short-term memory techniques

    Get PDF
    The optimisation and validation of a classifiers performance when applied to real world problems is not always effectively shown. In much of the literature describing the application of artificial neural network architectures to Human Activity Recognition (HAR) problems, postural transitions are grouped together and treated as a singular class. This paper proposes, investigates and validates the development of an optimised artificial neural network based on Long-Short Term Memory techniques (LSTM), with repeated cross validation used to validate the performance of the classifier. The results of the optimised LSTM classifier are comparable or better to that of previous research making use of the same dataset, achieving 95% accuracy under repeated 10-fold cross validation using grouped postural transitions. The work in this paper also achieves 94% accuracy under repeated 10-fold cross validation whilst treating each common postural transition as a separate class (and thus providing more context to each activity)

    Home detection of freezing of gait using Support Vector Machines through a single waist-worn triaxial accelerometer

    Get PDF
    Among Parkinson’s disease (PD) symptoms, freezing of gait (FoG) is one of the most debilitating. To assess FoG, current clinical practice mostly employs repeated evaluations over weeks and months based on questionnaires, which may not accurately map the severity of this symptom. The use of a non-invasive system to monitor the activities of daily living (ADL) and the PD symptoms experienced by patients throughout the day could provide a more accurate and objective evaluation of FoG in order to better understand the evolution of the disease and allow for a more informed decision-making process in making adjustments to the patient’s treatment plan. This paper presents a new algorithm to detect FoG with a machine learning approach based on Support Vector Machines (SVM) and a single tri-axial accelerometer worn at the waist. The method is evaluated through the acceleration signals in an outpatient setting gathered from 21 PD patients at their home and evaluated under two different conditions: first, a generic model is tested by using a leave-one-out approach and, second, a personalised model that also uses part of the dataset from each patient. Results show a significant improvement in the accuracy of the personalised model compared to the generic model, showing enhancement in the specificity and sensitivity geometric mean (GM) of 7.2%. Furthermore, the SVM approach adopted has been compared to the most comprehensive FoG detection method currently in use (referred to as MBFA in this paper). Results of our novel generic method provide an enhancement of 11.2% in the GM compared to the MBFA generic model and, in the case of the personalised model, a 10% of improvement with respect to the MBFA personalised model. Thus, our results show that a machine learning approach can be used to monitor FoG during the daily life of PD patients and, furthermore, personalised models for FoG detection can be used to improve monitoring accuracy.Peer ReviewedPostprint (published version

    Bi-LSTM network for multimodal continuous human activity recognition and fall detection

    Get PDF
    This paper presents a framework based on multi-layer bi-LSTM network (bidirectional Long Short-Term Memory) for multimodal sensor fusion to sense and classify daily activities’ patterns and high-risk events such as falls. The data collected in this work are continuous activity streams from FMCW radar and three wearable inertial sensors on the wrist, waist, and ankle. Each activity has a variable duration in the data stream so that the transitions between activities can happen at random times within the stream, without resorting to conventional fixed-duration snapshots. The proposed bi-LSTM implements soft feature fusion between wearable sensors and radar data, as well as two robust hard-fusion methods using the confusion matrices of both sensors. A novel hybrid fusion scheme is then proposed to combine soft and hard fusion to push the classification performances to approximately 96% accuracy in identifying continuous activities and fall events. These fusion schemes implemented with the proposed bi-LSTM network are compared with conventional sliding window approach, and all are validated with realistic “leaving one participant out” (L1PO) method (i.e. testing subjects unknown to the classifier). The developed hybrid-fusion approach is capable of stabilizing the classification performance among different participants in terms of reducing accuracy variance of up to 18.1% and increasing minimum, worst-case accuracy up to 16.2%

    Human Activity Recognition for AI-Enabled Healthcare Using Low-Resolution Infrared Sensor Data

    Get PDF
    This paper explores the feasibility of using low-resolution infrared (LRIR) image streams for human activity recognition (HAR) with potential application in e-healthcare. Two datasets based on synchronized multichannel LRIR sensors systems are considered for a comprehensive study about optimal data acquisition. A novel noise reduction technique is proposed for alleviating the effects of horizontal and vertical periodic noise in the 2D spatiotemporal activity profiles created by vectorizing and concatenating the LRIR frames. Two main analysis strategies are explored for HAR, including (1) manual feature extraction using texture-based and orthogonal-transformation-based techniques, followed by classification using support vector machine (SVM), random forest (RF), k-nearest neighbor (k-NN), and logistic regression (LR), and (2) deep neural network (DNN) strategy based on a convolutional long short-term memory (LSTM). The proposed periodic noise reduction technique showcases an increase of up to 14.15% using different models. In addition, for the first time, the optimum number of sensors, sensor layout, and distance to subjects are studied, indicating the optimum results based on a single side sensor at a close distance. Reasonable accuracies are achieved in the case of sensor displacement and robustness in detection of multiple subjects. Furthermore, the models show suitability for data collected in different environments

    Heart Rate Estimation During Physical Exercise Using Wrist-Type Ppg Sensors

    Get PDF
    Accurate heart rate monitoring during intense physical exercise is a challenging problem due to the high levels of motion artifacts (MA) in photoplethysmography (PPG) sensors. PPG is a non-invasive optical sensor that is being used in wearable devices to measure blood flow changes using the property of light reflection and absorption, allowing the extraction of vital signals such as the heart rate (HR). However, the sensor is susceptible to MA which increases during physical activity. This occurs since the frequency range of movement and HR overlaps, difficulting correct HR estimation. For this reason, MA removal has remained an active topic under research. Several approaches have been developed in the recent past and among these, a Kalman filter (KF) based approach showed promising results for an accurate estimation and tracking using PPG sensors. However, this previous tracker was demonstrated for a particular dataset, with manually tuned parameters. Moreover, such trackers do not account for the correct method for fusing data. Such a custom approach might not perform accurately in practical scenarios, where the amount of MA and the heart rate variability (HRV) depend on numerous, unpredictable factors. Thus, an approach to automatically tune the KF based on the Expectation-Maximization (EM) algorithm, with a measurement fusion approach is developed. The applicability of such a method is demonstrated using an open-source PPG database, as well as a developed synthetic generation tool that models PPG and accelerometer (ACC) signals during predetermined physical activities
    • 

    corecore