1,859 research outputs found

    Tools for improving high-dose-rate prostate cancer brachytherapy using three-dimensional ultrasound and magnetic resonance imaging

    Get PDF
    High-dose-rate brachytherapy (HDR-BT) is an interstitial technique for the treatment of intermediate and high-risk localized prostate cancer that involves placement of a radiation source directly inside the prostate using needles. Dose-escalated whole-gland treatments have led to improvements in survival, and tumour-targeted treatments may offer future improvements in therapeutic ratio. The efficacy of tumour-targeted HDR-BT depends on imaging tools to enable accurate dose delivery to prostate sub-volumes. This thesis is focused on implementing ultrasound tools to improve HDR-BT needle localization accuracy and efficiency, and evaluating dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) for tumour localization. First, we implemented a device enabling sagittally-reconstructed 3D (SR3D) ultrasound, which provides sub-millimeter resolution in the needle insertion direction. We acquired SR3D and routine clinical images in a cohort of 12 consecutive eligible HDR-BT patients, with a total of 194 needles. The SR3D technique provided needle insertion depth errors within 5 mm for 93\% of needles versus 76\% for the clinical imaging technique, leading to increased precision in dose delivered to the prostate. Second, we implemented an algorithm to automatically segment multiple HDR-BT needles in a SR3D image. The algorithm was applied to the SR3D images from the first patient cohort, demonstrating mean execution times of 11.0 s per patient and successfully segmenting 82\% of needles within 3 mm. Third, we augmented SR3D imaging with live-2D sagittal ultrasound for needle tip localization. This combined technique was applied to another cohort of 10 HDR-BT patients, reducing insertion depth errors compared to routine imaging from a range of [-8.1 mm, 7.7 mm] to [-6.2 mm, 5.9 mm]. Finally, we acquired DCE-MRI in 16 patients scheduled to undergo prostatectomy, using either high spatial resolution or high temporal resolution imaging, and compared the images to whole-mount histology. The high spatial resolution images demonstrated improved high-grade cancer classification compared to the high temporal resolution images, with areas under the receiver operating characteristic curve of 0.79 and 0.70, respectively. In conclusion, we have translated and evaluated specialized imaging tools for HDR-BT which are ready to be tested in a clinical trial investigating tumour-targeted treatment

    A review of artificial intelligence in prostate cancer detection on imaging

    Get PDF
    A multitude of studies have explored the role of artificial intelligence (AI) in providing diagnostic support to radiologists, pathologists, and urologists in prostate cancer detection, risk-stratification, and management. This review provides a comprehensive overview of relevant literature regarding the use of AI models in (1) detecting prostate cancer on radiology images (magnetic resonance and ultrasound imaging), (2) detecting prostate cancer on histopathology images of prostate biopsy tissue, and (3) assisting in supporting tasks for prostate cancer detection (prostate gland segmentation, MRI-histopathology registration, MRI-ultrasound registration). We discuss both the potential of these AI models to assist in the clinical workflow of prostate cancer diagnosis, as well as the current limitations including variability in training data sets, algorithms, and evaluation criteria. We also discuss ongoing challenges and what is needed to bridge the gap between academic research on AI for prostate cancer and commercial solutions that improve routine clinical care

    Toward optimization of target planning for magnetic resonance image-targeted, 3D transrectal ultrasound-guided fusion prostate biopsy

    Get PDF
    The current clinical standard for diagnosis of prostate cancer (PCa) is 2D transrectal ultrasound (TRUS)-guided biopsy. However, this procedure has a false negative rate of 21-47% and therefore many patients return for repeat biopsies. A potential solution for improving upon this problem is “fusion” biopsy, where magnetic resonance imaging (MRI) is used for PCa detection and localization prior to biopsy. In this procedure, tumours are delineated on pre-procedural MRI and registered to the 3D TRUS needle guidance modality. However, fusion biopsy continues to yield false negative results and there remains a gap in knowledge regarding biopsy needle target selection. Within-tumour needle targets are currently chosen ad hoc by the operating clinician without accounting for guidance system and registration errors. The objective of this thesis was to investigate how the choice of target selection strategy and number of biopsy attempts made per lesion may affect PCa diagnosis in the presence of needle delivery error. A fusion prostate biopsy simulation software platform was developed, which allowed for the investigation of how needle delivery error affects PCa diagnosis and cancer burden estimation. Initial work was conducted using 3D lesions contoured on MRI by collaborating radiologists. The results indicated that more than one core must be taken from the majority of lesions to achieve a sampling probability 95% for a biopsy system with needle delivery error ≥ 3.5 mm. Furthermore, it was observed that the optimal targeting scheme depends on the relative levels of systematic and random needle delivery errors inherent to the specific fusion biopsy system. Lastly, PCa tumours contoured on digital histology images by genitourinary pathologists were used to conduct biopsy simulations. The results demonstrated that needle delivery error has a substantial impact on the biopsy core involvement observed, and that targeting of high-grade lesions may result in higher core involvement variability compared with lesions of all grades. This work represents a first step toward improving the manner in which lesions are targeted using fusion biopsy. Successful integration of these findings into current fusion biopsy system operation could lead to earlier PCa diagnosis with the need for fewer repeat biopsy procedures

    MR to Ultrasound Registration for Image-Guided Prostate Biopsy

    Get PDF
    Transrectal ultrasound (TRUS) guided prostate biopsy is the standard approach for diagnosis of prostate cancer (PCa). However, due to the lack of image contrast of prostate tumors, it often results in false negatives. Magnetic Resonance Imaging (MRI) has been considered to be a promising imaging modality for noninvasive identification of PCa, since it can provide a high sensitivity and specificity for the detection of early stage PCa. Our main objective is to develop a registration method of 3D MR-TRUS images, allowing generation of volumetric 3D maps of targets identified in 3D MR images to be biopsied using 3D TRUS images. We proposed an image-based non-rigid registration approach which employs the modality independent neighborhood descriptor (MIND) as the local similarity feature. An efficient duality-based convex optimization-based algorithmic scheme was introduced to extract the deformations. The registration accuracy was evaluated using 20 patient images by calculating the target registration error (TRE) using manually identified corresponding intrinsic fiducials. Additional performance metrics (DSC, MAD, and MAXD) were also calculated by comparing the MR and TRUS manually segmented prostate surfaces in the registered images. Experimental results showed that the proposed method yielded an overall median TRE of 1.76 mm. In addition, we proposed a surface-based registration method, which first makes use of an initial rigid registration of 3D MR to TRUS using 6 manually placed corresponding landmarks in each image. Following the manual initialization, two prostate surfaces are segmented from 3D MR and TRUS images and then non-rigidly registered using a thin-plate spline algorithm. The registration accuracy was evaluated using 17 patient images by measuring TRE. Experimental results show that the proposed method yielded an overall mean TRE of 2.24 mm, which is favorably comparable to a clinical requirement for an error of less than 2.5 mm

    The future direction of imaging in prostate cancer: MRI with or without contrast injection

    Get PDF
    Background: Multiparametric MRI (mpMRI) is the "state of the art" management tool for patients with prostate cancer (PCa) suspicion. The role of non-contrast MRI is investigated to move toward a more personalized, less invasive, and highly cost-effective PCa diagnostic workup. Objective: To perform a non-systematic review of the existing literature to highlight strength and flaws of performing non-contrast MRI, and to provide a critical overview of the international scientific production on the topic. Materials and methods: Online databases (Medline, PubMed, and Web of Science) were searched for original articles, systematic review and meta-analysis, and expert opinion papers. Results: Several investigations have shown comparable diagnostic accuracy of biparametric (bpMRI) and mpMRI for the detection of PCa. The advantage of abandoning contrast-enhanced sequences improves operational logistics, lowering costs, acquisition time, and side effects. The main limitations of bpMRI are that most studies which compared the non-contrast and contrast MRI come from centers with high expertise that might not be reproducible in the general community setting; besides, reduced protocols might be insufficient for estimation of the intra- and extra-prostatic extension and regional disease. The mentioned observations suggest that low quality mpMRI for the general population, might represent the main shortage to overcome. Discussion: Non-contrast MRI future trends are likely represented by PCa screening and the application of artificial intelligence (AI) tools. PCa screening is still a controversial topic and bpMRI, and has become one of the most promising diagnostic applications, as it is a more sensitive test for PCa early detection, compared to serum PSA level test. Also, AI applications and radiomic have been the object of several studies investigating PCa detection using bpMRI, showing encouraging results. Conclusion: Today, the accessibility to MRI for early detection of PCa is a priority. Results from prospective, multicenter, multireader and paired validation studies are needed to provided evidence supporting its role in the clinical practice

    Image-based registration methods for quantification and compensation of prostate motion during trans-rectal ultrasound (TRUS)-guided biopsy

    Get PDF
    Prostate biopsy is the clinical standard for cancer diagnosis and is typically performed under two-dimensional (2D) transrectal ultrasound (TRUS) for needle guidance. Unfortunately, most early stage prostate cancers are not visible on ultrasound and the procedure suffers from high false negative rates due to the lack of visible targets. Fusion of pre-biopsy MRI to 3D TRUS for targeted biopsy could improve cancer detection rates and volume of tumor sampled. In MRI-TRUS fusion biopsy systems, patient or prostate motion during the procedure causes misalignments in the MR targets mapped to the live 2D TRUS images, limiting the targeting accuracy of the biopsy system. In order to sample smallest clinically significant tumours of 0.5 cm3with 95% confidence, the root mean square (RMS) error of the biopsy system needs to be The target misalignments due to intermittent prostate motion during the procedure can be compensated by registering the live 2D TRUS images acquired during the biopsy procedure to the pre-acquired baseline 3D TRUS image. The registration must be performed both accurately and quickly in order to be useful during the clinical procedure. We developed an intensity-based 2D-3D rigid registration algorithm and validated it by calculating the target registration error (TRE) using manually identified fiducials within the prostate. We discuss two different approaches that can be used to improve the robustness of this registration to meet the clinical requirements. Firstly, we evaluated the impact of intra-procedural 3D TRUS imaging on motion compensation accuracy since the limited anatomical context available in live 2D TRUS images could limit the robustness of the 2D-3D registration. The results indicated that TRE improved when intra-procedural 3D TRUS images were used in registration, with larger improvements in the base and apex regions as compared with the mid-gland region. Secondly, we developed and evaluated a registration algorithm whose optimization is based on learned prostate motion characteristics. Compared to our initial approach, the updated optimization improved the robustness during 2D-3D registration by reducing the number of registrations with a TRE \u3e 5 mm from 9.2% to 1.2% with an overall RMS TRE of 2.3 mm. The methods developed in this work were intended to improve the needle targeting accuracy of 3D TRUS-guided biopsy systems. The successful integration of the techniques into current 3D TRUS-guided systems could improve the overall cancer detection rate during the biopsy and help to achieve earlier diagnosis and fewer repeat biopsy procedures in prostate cancer diagnosis

    Magnetic Resonance Imaging-Guided Transurethral Ultrasound Ablation of Prostate Cancer

    Get PDF
    Purpose: Magnetic resonance imaging-guided transurethral ultrasound ablation uses directional thermal ultrasound under magnetic resonance imaging thermometry feedback control for prostatic ablation. We report 12-month outcomes from a prospective multicenter trial (TACT). Materials and methods: A total of 115 men with favorable to intermediate risk prostate cancer across 13 centers were treated with whole gland ablation sparing the urethra and apical sphincter. The co-primary 12-month endpoints were safety and efficacy. Results: In all, 72 (63%) had grade group 2 and 77 (67%) had NCCN® intermediate risk disease. Median treatment delivery time was 51 minutes with 98% (IQR 95-99) thermal coverage of target volume and spatial ablation precision of ±1.4 mm on magnetic resonance imaging thermometry. Grade 3 adverse events occurred in 9 (8%) men. The primary endpoint (U.S. Food and Drug Administration mandated) of prostate specific antigen reduction ≥75% was achieved in 110 of 115 (96%) with median prostate specific antigen reduction of 95% and nadir of 0.34 ng/ml. Median prostate volume decreased from 37 to 3 cc. Among 68 men with pretreatment grade group 2 disease, 52 (79%) were free of grade group 2 disease on 12-month biopsy. Of 111 men with 12-month biopsy data, 72 (65%) had no evidence of cancer. Erections (International Index of Erectile Function question 2 score 2 or greater) were maintained/regained in 69 of 92 (75%). Multivariate predictors of persistent grade group 2 at 12 months included intraprostatic calcifications at screening, suboptimal magnetic resonance imaging thermal coverage of target volume and a PI-RADS™ 3 or greater lesion at 12-month magnetic resonance imaging (p <0.05). Conclusions: The TACT study of magnetic resonance imaging-guided transurethral ultrasound whole gland ablation in men with localized prostate cancer demonstrated effective tissue ablation and prostate specific antigen reduction with low rates of toxicity and residual disease
    corecore