6 research outputs found

    Torsional Ultrasound Sensor Optimization for Soft Tissue Characterization

    Get PDF
    Torsion mechanical waves have the capability to characterize shear stiffness moduli of soft tissue. Under this hypothesis, a computational methodology is proposed to design and optimize a piezoelectrics-based transmitter and receiver to generate and measure the response of torsional ultrasonic waves. The procedure employed is divided into two steps: (i) a finite element method (FEM) is developed to obtain a transmitted and received waveform as well as a resonance frequency of a previous geometry validated with a semi-analytical simplified model and (ii) a probabilistic optimality criteria of the design based on inverse problem from the estimation of robust probability of detection (RPOD) to maximize the detection of the pathology defined in terms of changes of shear stiffness. This study collects different options of design in two separated models, in transmission and contact, respectively. The main contribution of this work describes a framework to establish such as forward, inverse and optimization procedures to choose a set of appropriate parameters of a transducer. This methodological framework may be generalizable for other different applications.This research was supported by the Intituto de Salud Carlos III, projects DTS15-00093 (EU-FEDER), UNGRIS-CE-3664, the Ministry of Education DPI2014-51870-R and Junta de Andalucia for projects P11-CTS-8089 and GGI3000IDIB

    Experimental Evidence of Generation and Reception by a Transluminal Axisymmetric Shear Wave Elastography Prototype

    Get PDF
    Experimental evidence on testing a non-ultrasonic-based probe for a new approach in transluminal elastography was presented. The proposed modality generated shear waves by inducing oscillatory rotation on the lumen wall. Detection of the propagated waves was achieved at a set of receivers in mechanical contact with the lumen wall. The excitation element of the probe was an electromagnetic rotational actuator whilst the sensing element was comprised by a uniform anglewise arrangement of four piezoelectric receivers. The prototype was tested in two soft-tissue-mimicking phantoms that contained lumenlike conduits and stiffer inclusions. The shear wave speed of the different components of the phantoms was characterized using shear wave elastography. These values were used to estimate the time-of-flight of the expected reflections. Ultrafast ultrasound imaging, based on Loupas' algorithm, was used to estimate the displacement field in transversal planes to the lumenlike conduit and to compare against the readouts from the transluminal transmission-reception tests. Experimental observations between ultrafast imaging and the transluminal probe were in good agreement, and reflections due to the stiffer inclusions were detected by the transluminal probe. The obtained experimental evidence provided proof-of-concept for the transluminal elastography probe and encouraged further exploration of clinical applications

    Experimental Evidence of Generation and Reception by a Transluminal Axisymmetric Shear Wave Elastography Prototype

    Get PDF
    Experimental evidence on testing a non-ultrasonic-based probe for a new approach in transluminal elastography was presented. The proposed modality generated shear waves by inducing oscillatory rotation on the lumen wall. Detection of the propagated waves was achieved at a set of receivers in mechanical contact with the lumen wall. The excitation element of the probe was an electromagnetic rotational actuator whilst the sensing element was comprised by a uniform anglewise arrangement of four piezoelectric receivers. The prototype was tested in two soft-tissue-mimicking phantoms that contained lumenlike conduits and stiffer inclusions. The shear wave speed of the different components of the phantoms was characterized using shear wave elastography. These values were used to estimate the time-of-flight of the expected reflections. Ultrafast ultrasound imaging, based on Loupas’ algorithm, was used to estimate the displacement field in transversal planes to the lumenlike conduit and to compare against the readouts from the transluminal transmission–reception tests. Experimental observations between ultrafast imaging and the transluminal probe were in good agreement, and reflections due to the stiffer inclusions were detected by the transluminal probe. The obtained experimental evidence provided proof-of-concept for the transluminal elastography probe and encouraged further exploration of clinical applications.Ministry of Education grant numbers EQC2018-004508- P, DPI2017-83859-R, and UNGR15-CE-3664Ministry of Health grant numbers DTS15/00093 and PI16/00339, and Junta de Andalucía grant numbers, PI-0107-2017 and PIN-0030-2017, and B-TEP-026- UGR18, IE2017-5537, P18-RT-1653 (Junta de Andalucía)Consejería de Economía, Conocimiento, Empresas y UniversidadEuropean Regional Development Fund (ERDF) SOMM17/6109/UG

    Characterization of a piezoelectric acoustic sensor fabricated for low-frequency applications: a comparative study of three methods

    Get PDF
    Piezoelectric transducers are widely used for generating acoustic energy, and choosing the right radiating element is crucial for efficient energy conversion. In recent decades, numerous studies have been conducted to characterize ceramics based on their elastic, dielectric, and electromechanical properties, which have improved our understanding of their vibrational behavior and aided in the manufacturing of piezoelectric transducers for ultrasonic applications. However, most of these studies have focused on the characterization of ceramics and transducers using electrical impedance to obtain resonance and anti-resonance frequencies. Few studies have explored other important quantities such as acoustic sensitivity using the direct comparison method. In this work, we present a comprehensive study that covers the design, manufacturing, and experimental validation of a small-sized, easy-to-assemble piezoelectric acoustic sensor for low-frequency applications, using a soft ceramic PIC255 from PI Ceramic with a diameter of 10 mm and a thickness of 5 mm. We present two methods, analytical and numerical, for sensor design, followed by experimental validation, allowing for a direct comparison of measurements with simulated results. This work provides a useful evaluation and characterization tool for future applications of ultrasonic measurement systems.This workwas supported by the grants PID2020-116329GB-C22 and TED2021-129336B-I00 funded by MCIN/AEI/10.13039/501100011033 and by the European Union NextGenerationEU/PRTR. This work is also a result of an internship funded by the Autonomous Community of the Región of Murcia through the Fundación Séneca—Agencia de Ciencia y Tecnología de la Región de Murcia (Seneca Foundation—Agency for Science and Technology in the Region of Murcia) and the European Union’s NextGenerationEU program

    Torsional wave elastography to assess the mechanical properties of the cornea

    Get PDF
    Corneal mechanical changes are believed to occur before any visible structural alterations observed during routine clinical evaluation. This study proposed developing an elastography technique based on torsional waves (TWE) adapted to the specificities of the cornea. By measuring the displacements in the propagation plane perpendicular to the axis of the emitter, the effect of guided waves in platelike media was proven negligible. Ex vivo experiments were carried out on porcine corneal samples considering a group of control and one group of alkali burn treatment ( NH 4OH) that modified the mechanical properties. Phase speed was recovered as a function of intraocular pressure (IOP), and a Kelvin-Voigt rheological model was fitted to the dispersion curves to estimate viscoelastic parameters. A comparison with uniaxial tensile testing with thin-walled assumptions was also performed. Both shear elasticity and viscosity correlated positively with IOP, being the elasticity lower and the viscosity higher for the treated group. The viscoelastic parameters ranged from 21.33 to 63.17 kPa, and from 2.82 to 5.30 Pa s, for shear elasticity and viscosity, respectively. As far as the authors know, no other investigations have studied this mechanical plane under low strain ratios, typical of dynamic elastography in corneal tissue. TWE reflected mechanical properties changes after treatment, showing a high potential for clinical diagnosis due to its rapid performance time and paving the way for future in vivo studies.Ministerio de Educacion, Cultura y Deporte Grant DPI2017-83859-R DPI2014-51870-R UNGR15-CE-3664 EQC2018-004508-PSpanish Government DTS15/00093 PI16/00339Instituto de Salud Carlos III y Fondos FederJunta de Andalucia PI-0107-2017 PIN-0030-2017 IE2017-5537MCIN/AEI - European Social Fund "Investing in your future" PRE2018-086085Consejeria de economia, conocimiento, empresas y universidad SOMM17/6109/UGR B-TEP-026- IE2017-5537 P18-RT-1653European Commission SOMM17/6109/UGR B-TEP-026- IE2017-5537 P18-RT-165

    Nonlinear fourth‐order elastic characterization of the cornea using torsional wave elastography

    Get PDF
    Measuring the mechanical nonlinear properties of the cornea remains challenging due to the lack of consensus in the methodology and in the models that effectively predict its behaviour. This study proposed developing a procedure to reconstruct nonlinear fourth-order elastic properties of the cornea based on a mathematical model derived from the theory of Hamilton et al. and using the torsional wave elastography (TWE) technique. In order to validate its diagnostic capability of simulated pathological conditions, two different groups were studied, non-treated cornea samples (n=7), and ammonium hydroxide (NH4OH) treated samples (n=7). All the samples were measured in-plane by a torsional wave device by increasing IOP from 5 to 25 mmHg with 5 mmHg steps. The results show a nonlinear variation of the shear wave speed with the IOP, with higher values for higher IOPs. Moreover, the shear wave speed values of the control group were higher than those of the treated group. The study also revealed significant differences between the control and treated groups for the Lamé parameter ���� (25.9–6.52 kPa), third-order elastic constant A (215.09–44.85 kPa), and fourth-order elastic constant D (523.5–129.63 kPa), with p-values of 0.010, 0.024, and 0.032, respectively. These findings demonstrate that the proposed procedure can distinguish between healthy and damaged corneas, making it a promising technique for detecting diseases associated with IOP alteration, such as corneal burns, glaucoma, or ocular hypertension
    corecore