6,078 research outputs found
The effect of pulsatile blood flow on blood pressure regulatory mechanisms
This paper demonstrates that the effect of pulsatile
blood flow on the baroreflex is to effectively reduce the gain of
the baroreflex loop. This has important implications for both
the development of integrative physiology models, which do
not include pulsatile blood flow, and the use of non-pulsatile
ventricular assist devices with either replace the heart or assist
the heart in achieving adequate blood circulation. To elucidate
the effect of the pulsatile nature of blood flow, we utilise the
concept of an equivalent nonlinearity to replace the baroreflex
curve, driven by a pulsatile blood flow/pressure signal, with
an equivalent nonlinearity corresponding to a non-pulsatile
situation. Tests are performed on a feedback model for the
peripheral resistance baroreflex and conclusions made to the
stability implications, using a describing function analysis
A delay recruitment model of the cardiovascular control system.
Copyright will be owned by Springer. We develop a nonlinear delay-differential equation for the human cardiovascular control system, and use it to explore blood pressure and heart rate variability under short-term baroreflex control. The model incorporates an intrinsically stable heart rate in the absence of nervous control, and features baroreflex influence on both heart rate and peripheral resistance. Analytical simplifications of the model allow a general investigation of the rôles played by gain and delay, and the effects of ageing.
An Integrated Analysis of the Physiological Effects of Space Flight: Executive Summary
A large array of models were applied in a unified manner to solve problems in space flight physiology. Mathematical simulation was used as an alternative way of looking at physiological systems and maximizing the yield from previous space flight experiments. A medical data analysis system was created which consist of an automated data base, a computerized biostatistical and data analysis system, and a set of simulation models of physiological systems. Five basic models were employed: (1) a pulsatile cardiovascular model; (2) a respiratory model; (3) a thermoregulatory model; (4) a circulatory, fluid, and electrolyte balance model; and (5) an erythropoiesis regulatory model. Algorithms were provided to perform routine statistical tests, multivariate analysis, nonlinear regression analysis, and autocorrelation analysis. Special purpose programs were prepared for rank correlation, factor analysis, and the integration of the metabolic balance data
Description, validation, and modification of the Guyton model for space-flight applications. Part A. Guyton model of circulatory, fluid and electrolyte control. Part B. Modification of the Guyton model for circulatory, fluid and electrolyte control
The mathematical model that has been a cornerstone for the systems analysis of space-flight physiological studies is the Guyton model describing circulatory, fluid and electrolyte regulation. The model and the modifications that are made to permit simulation and analysis of the stress of weightlessness are described
Flow competition between hepatic arterial and portal venous flow during hypothermic machine perfusion preservation of porcine livers
Hypothermic machine perfusion (HMP) is regarded as a better preservation method for donor livers than cold storage. During HMP, livers are perfused through the inlet blood vessels, namely the hepatic artery (HA) and the portal vein (PO. In previous HMP feasibility studies of porcine and human livers, we observed that the PV flow decreased while the HA flow increased. This flow competition restored either spontaneously or by lowering the HA pressure (P-HA). Since this phenomenon had never been observed before and because it affects the HMP stability, it is essential to gain more insight into the determinants of flow competition. To this end, we investigated the influence of the HMP boundary conditions on liver flows during controlled experiments. This paper presents the flow effects induced by increasing P-HA and by obstructing the outlet blood vessel, which is the vena cava inferior (VCI).
Flow competition was evoked by increasing P-HA to 55-70 mmHg, as well as by obstructing the VCI. Remarkably, a severe obstruction resulted in a repetitive and alternating tradeoff between the HA and PV flows. These phenomena could be related to intra-sinusoidal pressure alterations. Consequently, a higher P-HA is most likely transmitted to the sinusoidal level. This increased sinusoidal pressure reduces the pressure drop between the PV and the sinusoids, leading to a decreased PV perfusion. Flow competition has not been encountered or evoked under physiological conditions and should be taken into account for the design of liver HMP protocols. Nevertheless, more research is necessary to determine the optimal parameters for stable HMP
Impact of diabetes mellitus on ventricular structure, arterial stiffness, and pulsatile hemodynamics in heart failure with preserved ejection fraction
Background-Heterogeneity in the underlying processes that contribute to heart failure with preserved ejection fraction (HFpEF) is increasingly recognized. Diabetes mellitus is a frequent comorbidity in HFpEF, but its impact on left ventricular and arterial structure and function in HFpEF is unknown. Methods and Results-Weassessed the impact of diabetesmellitus on left ventricular cellular and interstitial hypertrophy (assessedwith cardiacmagnetic resonance imaging, including T1mapping pregadolinium and postgadolinium administration), arterial stiffness (assessed with arterial tonometry), and pulsatile arterial hemodynamics (assessed with in-office pressure-flow analyses and 24-hour ambulatory monitoring) among 53 subjects with HFpEF (32 diabetic and 21 nondiabetic subjects). Despite few differences in clinical characteristics, diabetic subjects with HFpEF exhibited a markedly greater left ventricular mass index (78.1 [95% CI, 70.4-85.9] g versus 63.6 [95% CI, 55.8-71.3] g; P=0.0093) and indexed extracellular volume (23.6 [95% CI, 21.2-26.1] mL/m(2) versus 16.2 [95% CI, 13.1-19.4] mL/m(2); P=0.0008). Pronounced aortic stiffening was also observed in the diabetic group (carotid-femoral pulse wave velocity, 11.86 [95% CI, 10.4-13.1] m/s versus 8.8 [95% CI, 7.5-10.1] m/s; P=0.0027), with an adverse pulsatile hemodynamic profile characterized by increased oscillatory power (315 [95% CI, 258-373] mWversus 190 [95% CI, 144-236] mW; P=0.0007), aortic characteristic impedance (0.154 [95% CI, 0.124-0.183] mmHg/mL per second versus 0.096 [95% CI, 0.072-0.121] mm Hg/mL per second; P=0.0024), and forward (59.5 [95% CI, 52.8-66.1] mm Hg versus 40.1 [95% CI, 31.6-48.6] mm Hg; P=0.0010) and backward (19.6 [95% CI, 16.2-22.9] mm Hg versus 14.1 [95% CI, 10.9-17.3] mm Hg; P=0.0169) wave amplitude. Abnormal pulsatile hemodynamics were also evident in 24-hour ambulatory monitoring, despite the absence of significant differences in 24-hour systolic blood pressure between the groups. Conclusions-Diabetes mellitus is a key determinant of left ventricular remodeling, arterial stiffness, adverse pulsatile hemodynamics, and ventricular-arterial interactions in HFpEF
Whole-body mathematical model for simulating intracranial pressure dynamics
A whole-body mathematical model (10) for simulating intracranial pressure dynamics. In one embodiment, model (10) includes 17 interacting compartments, of which nine lie entirely outside of intracranial vault (14). Compartments (F) and (T) are defined to distinguish ventricular from extraventricular CSF. The vasculature of the intracranial system within cranial vault (14) is also subdivided into five compartments (A, C, P, V, and S, respectively) representing the intracranial arteries, capillaries, choroid plexus, veins, and venous sinus. The body's extracranial systemic vasculature is divided into six compartments (I, J, O, Z, D, and X, respectively) representing the arteries, capillaries, and veins of the central body and the lower body. Compartments (G) and (B) include tissue and the associated interstitial fluid in the intracranial and lower regions. Compartment (Y) is a composite involving the tissues, organs, and pulmonary circulation of the central body and compartment (M) represents the external environment
Mathematical circulatory system model
A system and method of modeling a circulatory system including a regulatory mechanism parameter. In one embodiment, a regulatory mechanism parameter in a lumped parameter model is represented as a logistic function. In another embodiment, the circulatory system model includes a compliant vessel, the model having a parameter representing a change in pressure due to contraction of smooth muscles of a wall of the vessel
- …