10,109 research outputs found
Contribution of a smart transformer in the local primary control of a microgrid
In order to enable an easy participation of microgrids in the electricity markets, the smart transformer (ST) concept has been developed. The ST controls the power exchange between a microgrid and the utility network by only controlling its microgrid side voltage, instead of the conventional arrangement where new set points are communicated to all microgrid elements. When the voltage-based droop (VBD) control is implemented in the DG units, loads and storage elements, all microgrid units automatically respond to this change of microgrid voltage by altering their power output or consumption. However, this reference value of power exchange is dependent on (day-ahead) predictions of both consumption and (renewable) power generation. Hence, when these predictions prove to be inaccurate, the ST will still control the power exchange, but with consequently large variations of the microgrid voltage from its nominal value. It is suggested to take the real-time microgrid voltage into account when determining the reference power of the ST. This is presented in this paper by extending the ST's control strategy with a VBD control, such that the ST can contribute in the primary control. Simulations are included to analyze this primary control of the ST combined with VBD control of the other microgrid elements
European White Book on Real-Time Power Hardware in the Loop Testing : DERlab Report No. R- 005.0
The European White Book on Real-Time-Powerhardware-in-the-Loop testing is intended to serve as a reference document on the future of testing of electrical power equipment, with specifi c focus on the emerging hardware-in-the-loop activities and application thereof within testing facilities and procedures. It will provide an outlook of how this powerful tool can be utilised to support the development, testing and validation of specifi cally DER equipment. It aims to report on international experience gained thus far and provides case studies on developments and specifi c technical issues, such as the hardware/software interface. This white book compliments the already existing series of DERlab European white books, covering topics such as grid-inverters and grid-connected storag
Impact Assessment of Hypothesized Cyberattacks on Interconnected Bulk Power Systems
The first-ever Ukraine cyberattack on power grid has proven its devastation
by hacking into their critical cyber assets. With administrative privileges
accessing substation networks/local control centers, one intelligent way of
coordinated cyberattacks is to execute a series of disruptive switching
executions on multiple substations using compromised supervisory control and
data acquisition (SCADA) systems. These actions can cause significant impacts
to an interconnected power grid. Unlike the previous power blackouts, such
high-impact initiating events can aggravate operating conditions, initiating
instability that may lead to system-wide cascading failure. A systemic
evaluation of "nightmare" scenarios is highly desirable for asset owners to
manage and prioritize the maintenance and investment in protecting their
cyberinfrastructure. This survey paper is a conceptual expansion of real-time
monitoring, anomaly detection, impact analyses, and mitigation (RAIM) framework
that emphasizes on the resulting impacts, both on steady-state and dynamic
aspects of power system stability. Hypothetically, we associate the
combinatorial analyses of steady state on substations/components outages and
dynamics of the sequential switching orders as part of the permutation. The
expanded framework includes (1) critical/noncritical combination verification,
(2) cascade confirmation, and (3) combination re-evaluation. This paper ends
with a discussion of the open issues for metrics and future design pertaining
the impact quantification of cyber-related contingencies
Quantification of efficiency improvements from integration of battery energy storage systems and renewable energy sources into domestic distribution networks
Due to the increasing use of renewable, non-controllable energy generation systems energy storage systems (ESS) are seen as a necessary part of future power delivery systems. ESS have gained research interest and practical implementation over the past decade and this is expected to continue into the future. This is due to the economic and operational benefits for both network operators and customers, battery energy storage system (BESS) is used as the main focus of this research paper. This paper presents an analytical study of the benefits of deploying distributed BESS in an electrical distribution network (DN). The work explores the optimum location of installing BESS and its impact on the DN performance and possible future investment. This study provides a comparison between bulk energy storage installed at three different locations; medium voltage (MV) side and low voltage (LV) side of the distribution transformer (DT) and distributed energy storage at customers’ feeders. The performance of a typical UK DN is examined under different penetration levels of wind energy generation units and BESS. The results show that the minimum storage size is obtained when BESS is installed next to the DT. However, the power loss is reduced to its minimum when BESS and wind energy are both distributed at load busbars. The study demonstrates that BESS installation has improved the loss of life factor of the distribution transformer
Power quality and electromagnetic compatibility: special report, session 2
The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems.
Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages).
The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks:
Block 1: Electric and Magnetic Fields, EMC, Earthing systems
Block 2: Harmonics
Block 3: Voltage Variation
Block 4: Power Quality Monitoring
Two Round Tables will be organised:
- Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13)
- Reliability Benchmarking - why we should do it? What should be done in future? (RT 15
Recommended from our members
Secure High DER Penetration Power Distribution Via Autonomously Coordinated Volt/VAR Control
Traditionally voltage control in distribution power system (DPS) is performed through voltage regulating devices (VRDs) including on load tap changers (OLTCs), step voltage regulators (SVRs), and switched capacitor banks (SCBs). The recent IEEE 1547-2018 from March 2018 requires inverter fed distributed energy resources (DERs) to contribute reactive power to support the grid voltage. To accommodate VAR from DERs, well-organized control algorithm is required to use in this mode to avoid grid oscillations and unintended switching operations of VRDs. This paper presents two voltage control strategies (i) static voltage control considering voltage-reactive power mode (IEEE 1547-2018), (ii) dynamic and extensive voltage control with maximum utilization of DER capacity and system stability. Further, effective time-graded control is implemented between VRDs and DER units to reduce the simultaneous and negative operation. The proposed voltage control strategies are tested in a realistic 140-bus southern California distribution power system through extensive time-domain simulation studies. The results show that voltage quality in a distribution system is effectively achieved through the proposed voltage control strategies with a significantly reduction in the number of switching operations of VRDs. In addition, proposed voltage control strategies increase reliability and security of the DPS during unexpected failures
Recommended from our members
Challenges to the Integration of Renewable Resources at High System Penetration
Successfully integrating renewable resources into the electric grid at penetration levels to meet a 33 percent Renewables Portfolio Standard for California presents diverse technical and organizational challenges. This report characterizes these challenges by coordinating problems in time and space, balancing electric power on a range of scales from microseconds to decades and from individual homes to hundreds of miles. Crucial research needs were identified related to grid operation, standards and procedures, system design and analysis, and incentives, and public engagement in each scale of analysis. Performing this coordination on more refined scales of time and space independent of any particular technology, is defined as a “smart grid.” “Smart” coordination of the grid should mitigate technical difficulties associated with intermittent and distributed generation, support grid stability and reliability, and maximize benefits to California ratepayers by using the most economic technologies, design and operating approaches
- …