8,806 research outputs found

    Microcontroller-Based Seat Occupancy Detection and Classification

    Get PDF
    This paper presents a microcontroller-based measurement system to detect and confirm the presence of a subject in a chair. The system relies on a single Force Sensing Resistor (FSR), which may be arranged in the seat or backrest of the chair, that undergoes a sudden resistance change when a subject/object is seated/placed over the chair. In order to distinguish between a subject and an inanimate object, the system also monitors small-signal variations of the FSR resistance caused by respiration. These resistance variations are then directly measured by a low-cost general-purpose microcontroller without using either an analogue processing stage or an analogue-to-digital converter, thus resulting in a low-cost, low-power, compact design solution.Peer ReviewedPostprint (published version

    Remote monitoring of biodynamic activity using electric potential sensors

    Get PDF
    Previous work in applying the electric potential sensor to the monitoring of body electrophysiological signals has shown that it is now possible to monitor these signals without needing to make any electrical contact with the body. Conventional electrophysiology makes use of electrodes which are placed in direct electrical contact with the skin. The electric potential sensor requires no cutaneous electrical contact, it operates by sensing the displacement current using a capacitive coupling. When high resolution body electrophysiology is required a strong (capacitive) coupling is used to maximise the collected signal. However, in remote applications where there is typically an air-gap between the body and the sensor only a weak coupling can be achieved. In this paper we demonstrate that the electric potential sensor can be successfully used for the remote sensing and monitoring of bioelectric activity. We show examples of heart-rate measurements taken from a seated subject using sensors mounted in the chair. We also show that it is possible to monitor body movements on the opposite side of a wall to the sensor. These sensing techniques have biomedical applications for non-contact monitoring of electrophysiological conditions and can be applied to passive through-the-wall surveillance systems for security applications

    A Review on Pressure Ulcer: Aetiology, Cost, Detection and Prevention Systems

    Get PDF
    Pressure ulcer (also known as pressure sore, bedsore, ischemia, decubitus ulcer) is a global challenge for today’s healthcare society. Found in several locations in the human body such as the sacrum, heel, back of the head, shoulder, knee caps, it occurs when soft tissues are under continuous loading and a subject’s mobility is restricted (bedbound/chair bound). Blood flow in soft tissues becomes insufficient leading to tissue necrosis (cell death) and pressure ulcer. The subject’s physiological parameters (age, body mass index) and types of body support surface materials (mattress) are also factors in the formation of pressure ulcer. The economic impacts of these are huge, and the subject’s quality of life is reduced in many ways. There are several methods of detecting and preventing ulceration in human body. Detection depends on assessing local pressure on tissue and prevention on scales of risk used to assess a subject prior to admission. There are also various types of mattresses (air cushioned/liquid filled/foam) available to prevent ulceration. But, despite this work, pressure ulcers remain common.This article reviews the aetiology, cost, detection and prevention of these ulcers

    Characterization of dielectric charging in RF MEMS capacitive switches

    Get PDF
    RF MEMS capacitive switches show great promise for use in wireless communication devices such as mobile phones, but the successful application of these switches is hindered by reliability concerns: charge injection in the dielectric layer (SiN) can cause irreversible stiction of the moving part of the switch. We present a new way to characterize charge injection. By stressing the dielectric with electric fields on the order of 1 MV/cm, we inject charge in the dielectric, and use a new method to measure the effects it has on the C-V curve. Instead of measuring the change in the pull-in voltage, this method measures the change in the voltage at which the capacitance is minimal. This way, no extra charge is injected during the measurement of the amount of injected charge, which reduces the effect it has on the tested switches, so that the effect of the intentionally induced stress voltage is not obscured by the measurement method

    Fast RF-CV characterization through high-speed 1-port S-parameter measurements

    Get PDF
    We present a novel method to measure the capacitance-voltage relation of an electronic device. The approach is accurate, very fast, and cost-effective compared to the existing off-the-shelf solutions. Capacitances are determined using a single-frequency 1-port S-parameter setup constructed from discrete components. We introduce a new way to correct for non-linearities of the used components, which greatly increases the accuracy with which the phase and magnitude of the reflected signal is measured. The measurement technique is validated on an RF-MEMS capacitive switch and a BST tunable capacitor. Complete capacitance-voltage curves are measured in less than a millisecond, with a measurement accuracy well below 1%.\ud \u

    Sub-Pixel Response Measurement of Near-Infrared Sensors

    Get PDF
    Wide-field survey instruments are used to efficiently observe large regions of the sky. To achieve the necessary field of view, and to provide a higher signal-to-noise ratio for faint sources, many modern instruments are undersampled. However, precision photometry with undersampled imagers requires a detailed understanding of the sensitivity variations on a scale much smaller than a pixel. To address this, a near-infrared spot projection system has been developed to precisely characterize near-infrared focal plane arrays and to study the effect of sub-pixel non uniformity on precision photometry. Measurements of large format near-infrared detectors demonstrate the power of this system for understanding sub-pixel response.Comment: 9 pages, 13 figures, submitted to PAS

    Physical Multi-Layer Phantoms for Intra-Body Communications

    Full text link
    This paper presents approaches to creating tissue mimicking materials that can be used as phantoms for evaluating the performance of Body Area Networks (BAN). The main goal of the paper is to describe a methodology to create a repeatable experimental BAN platform that can be customized depending on the BAN scenario under test. Comparisons between different material compositions and percentages are shown, along with the resulting electrical properties of each mixture over the frequency range of interest for intra-body communications; 100 KHz to 100 MHz. Test results on a composite multi-layer sample are presented confirming the efficacy of the proposed methodology. To date, this is the first paper that provides guidance on how to decide on concentration levels of ingredients, depending on the exact frequency range of operation, and the desired matched electrical characteristics (conductivity vs. permittivity), to create multi-layer phantoms for intra-body communication applications

    Investigation into intermodulation distortion in HEMTs using a quasi-2-D physical model

    Get PDF
    The need for both linear and efficient pseudomorphic high electron-mobility transistors (pHEMTs) for modern wireless handsets necessitates a thorough understanding of the origins of intermodulation distortion at the device level. For the first time, the dynamic large-signal internal physical behavior of a pHEMT is examined using a quasi-two-dimensional physical device model. The model accounts fully for device-circuit interaction and is validated experimentally for a two-tone experiment around 5 GHz

    On the Trade-Off Between Quality Factor and Tuning Ratio in Tunable High-Frequency Capacitors

    Get PDF
    A benchmark of tunable and switchable devices at microwave frequencies is presented on the basis of physical limitations to show their potential for reconfigurable cellular applications. Performance limitations are outlined for each given technology focusing on the quality factor (Q) and tuning ratio (eta) as figures of merit. The state of the art in terms of these figures of merit of several tunable and switchable technologies is visualized and discussed. If the performance of these criteria is not met, the application will not be feasible. The quality factor can typically be traded off for tuning ratio. The benchmark of tunable capacitor technologies shows that transistor-switched capacitors, varactor diodes, and ferroelectric varactors perform well at 2 GHz for tuning ratios below 3, with an advantage for GaAs varactor diodes. Planar microelectromechanical capacitive switches have the potential to outperform all other technologies at tuning ratios higher than 8. Capacitors based on tunable dielectrics have the highest miniaturization potential, whereas semiconductor devices benefit from the existing manufacturing infrastructure
    corecore