    Non-uniform resolution and partial volume recovery in tomographic image reconstruction methods

    Get PDF
    Acquired data in tomographic imaging systems are subject to physical or detector based image degrading effects. These effects need to be considered and modeled in order to optimize resolution recovery. However, accurate modeling of the physics of data and acquisition processes still lead to an ill-posed reconstruction problem, because real data is incomplete and noisy. Real images are always a compromise between resolution and noise; therefore, noise processes also need to be fully considered for optimum bias variance trade off. Image degrading effects and noise are generally modeled in the reconstruction methods, while, statistical iterative methods can better model these effects, with noise processes, as compared to the analytical methods. Regularization is used to condition the problem and explicit regularization methods are considered better to model various noise processes with an extended control over the reconstructed image quality. Emission physics through object distribution properties are modeled in form of a prior function. Smoothing and edge-preserving priors have been investigated in detail and it has been shown that smoothing priors over-smooth images in high count areas and result in spatially non-uniform and nonlinear resolution response. Uniform resolution response is desirable for image comparison and other image processing tasks, such as segmentation and registration. This work proposes methods, based on MRPs in MAP estimators, to obtain images with almost uniform and linear resolution characteristics, using nonlinearity of MRPs as a correction tool. Results indicate that MRPs perform better in terms of response linearity, spatial uniformity and parameter sensitivity, as compared to QPs and TV priors. Hybrid priors, comprised of MRPs and QPs, have been developed and analyzed for their activity recovery performance in two popular PVC methods and for an analysis of list-mode data reconstruction methods showing that MPRs perform better than QPs in different situations

    Statistical Sinogram Restoration in Dual-Energy CT for PET Attenuation Correction

    Full text link
    Dual-energy (DE) X-ray computed tomography (CT) has been found useful in various applications. In medical imaging, one promising application is using low-dose DECT for attenuation correction in positron emission tomography (PET). Existing approaches to sinogram material decomposition ignore noise characteristics and are based on logarithmic transforms, producing noisy component sinogram estimates for low-dose DECT. In this paper, we propose two novel sinogram restoration methods based on statistical models: penalized weighted least square (PWLS) and penalized likelihood (PL), yielding less noisy component sinogram estimates for low-dose DECT than classical methods. The proposed methods consequently provide more precise attenuation correction of the PET emission images than do previous methods for sinogram material decomposition with DECT. We report simulations that compare the proposed techniques and existing approaches.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85900/1/Fessler11.pd

    4-D Tomographic Inference: Application to SPECT and MR-driven PET

    Get PDF
    Emission tomographic imaging is framed in the Bayesian and information theoretic framework. The first part of the thesis is inspired by the new possibilities offered by PET-MR systems, formulating models and algorithms for 4-D tomography and for the integration of information from multiple imaging modalities. The second part of the thesis extends the models described in the first part, focusing on the imaging hardware. Three key aspects for the design of new imaging systems are investigated: criteria and efficient algorithms for the optimisation and real-time adaptation of the parameters of the imaging hardware; learning the characteristics of the imaging hardware; exploiting the rich information provided by depthof- interaction (DOI) and energy resolving devices. The document concludes with the description of the NiftyRec software toolkit, developed to enable 4-D multi-modal tomographic inference

    Estimation of the Image Quality in Emission Tomography: Application to Optimization of SPECT System Design

    Get PDF
    In Emission Tomography the design of the Imaging System has a great influence on the quality of the output image. Optimisation of the system design is a difficult problem due to the computational complexity and to the challenges in its mathematical formulation. In order to compare different system designs, an efficient and effective method to calculate the Image Quality is needed. In this thesis the statistical and deterministic methods for the calculation of the uncertainty in the reconstruction are presented. In the deterministic case, the Fisher Information Matrix (FIM) formalism can be employed to characterize such uncertainty. Unfortunately, computing, storing and inverting the FIM is not feasible with 3D imaging systems. In order to tackle the problem of the computational load in calculating the inverse of the FIM a novel approximation, that relies on a sub-sampling of the FIM, is proposed. The FIM is calculated over a subset of voxels arranged in a grid that covers the whole volume. This formulation reduces the computational complexity in inverting the FIM but nevertheless accounts for the global interdependence between the variables, for the acquisition geometry and for the object dependency. Using this approach, the noise properties as a function of the system geometry parameterisation were investigated for three different cases. In the first study, the design of a parallel-hole collimator for SPECT is optimised. The new method can be applied to evaluating problems like trading-off collimator resolution and sensitivity. In the second study, the reconstructed image quality was evaluated in the case of truncated projection data; showing how the subsampling approach is very accurate for evaluating the effects of missing data. Finally, the noise properties of a D-SPECT system were studied for varying acquisition protocols; showing how the new method is well-suited to problems like optimising adaptive data sampling schemes

    What scans we will read: imaging instrumentation trends in clinical oncology

    Get PDF
    Oncological diseases account for a significant portion of the burden on public healthcare systems with associated costs driven primarily by complex and long-lasting therapies. Through the visualization of patient-specific morphology and functional-molecular pathways, cancerous tissue can be detected and characterized non- invasively, so as to provide referring oncologists with essential information to support therapy management decisions. Following the onset of stand-alone anatomical and functional imaging, we witness a push towards integrating molecular image information through various methods, including anato-metabolic imaging (e.g., PET/ CT), advanced MRI, optical or ultrasound imaging. This perspective paper highlights a number of key technological and methodological advances in imaging instrumentation related to anatomical, functional, molecular medicine and hybrid imaging, that is understood as the hardware-based combination of complementary anatomical and molecular imaging. These include novel detector technologies for ionizing radiation used in CT and nuclear medicine imaging, and novel system developments in MRI and optical as well as opto-acoustic imaging. We will also highlight new data processing methods for improved non-invasive tissue characterization. Following a general introduction to the role of imaging in oncology patient management we introduce imaging methods with well-defined clinical applications and potential for clinical translation. For each modality, we report first on the status quo and point to perceived technological and methodological advances in a subsequent status go section. Considering the breadth and dynamics of these developments, this perspective ends with a critical reflection on where the authors, with the majority of them being imaging experts with a background in physics and engineering, believe imaging methods will be in a few years from now. Overall, methodological and technological medical imaging advances are geared towards increased image contrast, the derivation of reproducible quantitative parameters, an increase in volume sensitivity and a reduction in overall examination time. To ensure full translation to the clinic, this progress in technologies and instrumentation is complemented by progress in relevant acquisition and image-processing protocols and improved data analysis. To this end, we should accept diagnostic images as “data”, and – through the wider adoption of advanced analysis, including machine learning approaches and a “big data” concept – move to the next stage of non-invasive tumor phenotyping. The scans we will be reading in 10 years from now will likely be composed of highly diverse multi- dimensional data from multiple sources, which mandate the use of advanced and interactive visualization and analysis platforms powered by Artificial Intelligence (AI) for real-time data handling by cross-specialty clinical experts with a domain knowledge that will need to go beyond that of plain imaging

    Development and Implementation of Fully 3D Statistical Image Reconstruction Algorithms for Helical CT and Half-Ring PET Insert System

    Get PDF
    X-ray computed tomography: CT) and positron emission tomography: PET) have become widely used imaging modalities for screening, diagnosis, and image-guided treatment planning. Along with the increased clinical use are increased demands for high image quality with reduced ionizing radiation dose to the patient. Despite their significantly high computational cost, statistical iterative reconstruction algorithms are known to reconstruct high-quality images from noisy tomographic datasets. The overall goal of this work is to design statistical reconstruction software for clinical x-ray CT scanners, and for a novel PET system that utilizes high-resolution detectors within the field of view of a whole-body PET scanner. The complex choices involved in the development and implementation of image reconstruction algorithms are fundamentally linked to the ways in which the data is acquired, and they require detailed knowledge of the various sources of signal degradation. Both of the imaging modalities investigated in this work have their own set of challenges. However, by utilizing an underlying statistical model for the measured data, we are able to use a common framework for this class of tomographic problems. We first present the details of a new fully 3D regularized statistical reconstruction algorithm for multislice helical CT. To reduce the computation time, the algorithm was carefully parallelized by identifying and taking advantage of the specific symmetry found in helical CT. Some basic image quality measures were evaluated using measured phantom and clinical datasets, and they indicate that our algorithm achieves comparable or superior performance over the fast analytical methods considered in this work. Next, we present our fully 3D reconstruction efforts for a high-resolution half-ring PET insert. We found that this unusual geometry requires extensive redevelopment of existing reconstruction methods in PET. We redesigned the major components of the data modeling process and incorporated them into our reconstruction algorithms. The algorithms were tested using simulated Monte Carlo data and phantom data acquired by a PET insert prototype system. Overall, we have developed new, computationally efficient methods to perform fully 3D statistical reconstructions on clinically-sized datasets

    SPECT imaging with rotating slat collimator

    Get PDF

    Iterative CT reconstruction from few projections for the nondestructive post irradiation examination of nuclear fuel assemblies

    Get PDF
    The core components (e.g. fuel assemblies, spacer grids, control rods) of the nuclear reactors encounter harsh environment due to high temperature, physical stress, and a tremendous level of radiation. The integrity of these elements is crucial for safe operation of the nuclear power plants. The Post Irradiation Examination (PIE) can reveal information about the integrity of the elements during normal operations and off‐normal events. Computed tomography (CT) is a tool for evaluating the structural integrity of elements non-destructively. CT requires many projections to be acquired from different view angles after which a mathematical algorithm is adopted for reconstruction. Obtaining many projections is laborious and expensive in nuclear industries. Reconstructions from a small number of projections are explored to achieve faster and cost-efficient PIE. Classical reconstruction algorithms (e.g. filtered back projection) cannot offer stable reconstructions from few projections and create severe streaking artifacts. In this thesis, conventional algorithms are reviewed, and new algorithms are developed for reconstructions of the nuclear fuel assemblies using few projections. CT reconstruction from few projections falls into two categories: the sparse-view CT and the limited-angle CT or tomosynthesis. Iterative reconstruction algorithms are developed for both cases in the field of compressed sensing (CS). The performance of the algorithms is assessed using simulated projections and validated through real projections. The thesis also describes the systematic strategy towards establishing the conditions of reconstructions and finds the optimal imaging parameters for reconstructions of the fuel assemblies from few projections. --Abstract, page iii
    • 

    corecore