    High frequency impedance based fault location in distribution system with DGs

    Get PDF
    Distributed generations (DGs) in the distribution systems are connected into the buses using power electronic converters. During fault, it is challenging to provide a constant impedance model for DGs in the system frequency due to the variable converter control strategies. System frequency impedance measurement based fault locations can be influenced by the converters’ fault behaviour. This study addresses this problem by proposing a wide-area high-frequency impedance comparison based fault location technique. The high-frequency impedance model of DG is provided. Based on the constant DG impedance model in high-frequency range, the faulted line sections can be distinguished by comparing the measured impedance differences without requiring the exact distribution system parameters. Simulation results show that the proposed wide-area transient measurements based fault location method can provide accurate faulted sections in the distribution systems with DGs regardless of the load and DG output variations, measurement noise, unbalanced loads and islanding operations

    High frequency impedance based fault location in distribution system with DGs

    Get PDF
    Distributed Generations (DGs) with power electronic devices and their control loops will cause distortion to the fault currents and result in errors for power frequency measurement based fault locations. This might jeopardize the distribution system fault restoration and reduce the grid resilience. The proposed method uses high frequency (up to 3kHz) fault information and short window measurement to avoid the influence of DG control loops. Applying the DG high frequency impedance model, faults can be accurately located by measuring the system high frequency line reactance. Assisted with the DG side recorded unsynchronized data, this method can be employed to distribution systems with multiple branches and laterals

    Sparse Voltage Measurement-Based Fault Location Using Intelligent Electronic Devices

    Get PDF
    This paper proposes a fault-section location method based on sparse measurements, aimed at asymmetrical faults. A virtual current vector is defined to indicate the faulted section, which is sufficiently sparse except that the fault position corresponding entries are nonzero. To simplify the algorithm, the virtual vector is fixed by amplitudes of voltages and impedances and the feasibility is demonstrated. The Bayesian Compressive Sensing theory is introduced to reduce the number of required intelligent electronic devices (IEDs). In addition, the minimal number of IEDs and their allocation are discussed. The performance of the proposed method is validated in a 69-bus, 12.66 kV distribution system with six distributed generations (DGs) in response to various fault scenarios. The simulation results show that the method is robust for single-phase, double-phase, and double-phase to ground faults with high resistance under noisy condition. Furthermore, the method is applicable for networks with inverter interfaced DGs

    Estudio del uso y contribución de la inteligencia artificial para la operación en redes eléctricas

    Get PDF
    Este estudio tiene como objetivo mostrar el panorama actual de la operación de las redes eléctricas con la influencia de la inteligencia artificial (IA), la cual a través de sus técnicas y algoritmos que la respaldan, ha venido dando aportes significativos. Se abarco una amplia literatura, logrando mostrar la perspectiva de sus bondades, y su aporte de forma general, destacando sus diferentes usos y contribuciones para el cumplimiento en la operación de las redes eléctricas. El estudio muestra características y usos de la IA en la operación del sistema de distribución eléctrica. Asocia las técnicas que más se han destacado para contribuir en la operación de las redes de distribución eléctrica, generando valor de grandes cantidades de datos. Se destacan los procesos necesarios para la implementación de la IA en las redes eléctricas comprendiendo elementos físicos, humanos y virtuales. Las ventajas que proyecta la IA abarcan la eficiencia, comodidad y confiabilidad; entre sus desventajas se identificaron la falta de: hardware, software, política regulatoria, seguridad, escasa actualización de tecnologías y capacitación humana. Se encontró que la IA en las redes eléctricas requiere de la digitalización para poder habilitar todos sus beneficios y generando una mayor resiliencia en estas. Finalmente, se concluyó que la IA es una herramienta clave para la operación presente y futura de las redes eléctricas, donde se recomienda la incorporación de tecnologías, hardware, software, políticas regulatorias y capacitación humana, para dar el paso hacia un progreso óptimo y descentralizado

    Fuzzy Inference System Approach for Locating Series, Shunt, and Simultaneous Series-Shunt Faults in Double Circuit Transmission Lines

    Get PDF
    Many schemes are reported for shunt fault location estimation, but fault location estimation of series or open conductor faults has not been dealt with so far. The existing numerical relays only detect the open conductor (series) fault and give the indication of the faulty phase(s), but they are unable to locate the series fault. The repair crew needs to patrol the complete line to find the location of series fault. In this paper fuzzy based fault detection/classification and location schemes in time domain are proposed for both series faults, shunt faults, and simultaneous series and shunt faults. The fault simulation studies and fault location algorithm have been developed using Matlab/Simulink. Synchronized phasors of voltage and current signals of both the ends of the line have been used as input to the proposed fuzzy based fault location scheme. Percentage of error in location of series fault is within 1% and shunt fault is 5% for all the tested fault cases. Validation of percentage of error in location estimation is done using Chi square test with both 1% and 5% level of significance

    Fault Management in DC Microgrids:A Review of Challenges, Countermeasures, and Future Research Trends

    Get PDF
    The significant benefits of DC microgrids have instigated extensive efforts to be an alternative network as compared to conventional AC power networks. Although their deployment is ever-growing, multiple challenges still occurred for the protection of DC microgrids to efficiently design, control, and operate the system for the islanded mode and grid-tied mode. Therefore, there are extensive research activities underway to tackle these issues. The challenge arises from the sudden exponential increase in DC fault current, which must be extinguished in the absence of the naturally occurring zero crossings, potentially leading to sustained arcs. This paper presents cut-age and state-of-the-art issues concerning the fault management of DC microgrids. It provides an account of research in areas related to fault management of DC microgrids, including fault detection, location, identification, isolation, and reconfiguration. In each area, a comprehensive review has been carried out to identify the fault management of DC microgrids. Finally, future trends and challenges regarding fault management in DC-microgrids are also discussed

    Coordinated Control of Distributed Energy Resources in Islanded Microgrids

    Get PDF
    As the penetration of the distributed energy resources (DERs) in the power grid increases,new challenges are revealed, including: stability issues, frequency fluctuations, voltage control, protection system coordination, etc. A systematic approach for dealing with those issues is to view the DERs and associated loads as a subsystem or a microgrid (MG). MGs can operate either in the grid connected or islanded modes. As opposed to the grid connected mode, the voltage and frequency regulation and load/generation balancing during islanded mode is solely dependent on the local generation units. Therefore, stable and reliable operation of islanded MGs requires a real time coordinated control scheme. Conventionally, such coordination is achieved by means of the active power-frequency and reactive powervoltage droop control schemes. The conventional droop method, which is based on P-f droop concept in power systems, lacks compatibility with the resistive nature of networks as well as the low inertia of electronically interfaced DER units in MGs. As a result, it features a slow dynamic response but also a low power quality due to frequency and voltage fluctuations. This PhD research proposes a novel droop concept based on the global positioning system (GPS) and voltage-current (V-I) droop characteristics for coordination of inverter-based DER units in islanded MGs. The concept of V-I droop control is introduced in Chapter 2. In this control approach, each DER is equipped with a GPS receiver, which produces a pulse at frequency of 1Hz (1PPS). Since all GPS receivers are locked to atomic clocks of the GPS satellites, the 1PPS signal can be utilized to synchronize the time reference of the DER units. Using the common time reference and fixing the frequency at the nominal value, all of the units can share a common synchronous rotating reference frame (SRRF). Furthermore, proportional load sharing is achieved by drooping the d and q axis components of the reference voltage with respect to the d and q axis components of current, respectively. The proposed scheme not only circumvents the issue of frequency fluctuations but also is in accordance with the fast dynamics of inverter-based DER units and resistive nature of the networks in islanded MGs. The V-I droop scheme, in its basic form, relies on availability of GPS signals at each of the DER units. With the intention of improving the MG robustness with respect to GPS signal failure, a new control strategy based on V-I droop concept is presented Chapter 3. In this method, an adaptive reactive power-frequency droop scheme is used as a backup for the V-I droop controller to ensure synchronization in case of a GPS signal failure. Droop control schemes in general, and the proposed V-I droop strategy in particular are characterized by non-ideal sharing of current among the DER units due to the variations of voltage along the MGs. In order to improve the sharing accuracy of the V-I droop scheme iv while regulating the average voltage at the nominal value, a new distributed secondary control method based on consensus protocol is proposed in Chapter 4. In this method, the daxis droop characteristics is altered so as to regulate the average microgrid voltage to the rated value but also guarantee proper sharing of active power among the DERs. Additionally, the q-axis component of voltage is adjusted to perform proper sharing of current. Generally, DERs might be supplied from different energy sources, including renewables and storage systems. The intermittency of renewable energy resources on one hand and the limited capacity of the energy storage systems on the other hand, necessitate modification of droop characteristics based on an energy management plan. In Chapter 5, a novel distributed secondary control strategy is introduced for power management of integrated photovoltaicbattery DER units in islanded MGs. The distributed secondary controllers are coordinated based on a leader-follower framework, where the leader restores the MG voltage to the rated value and the followers pursue energy management. Unbalanced and nonlinear loads, which are quite common in MGs, adversely affect the power quality and sharing accuracy. In order to mitigate those issues, two new solutions are proposed in this thesis. In the first approach (Chapter 6), a new supplementary droop control scheme is added to the V-I droop controller to reduce the voltage unbalance while preventing current and power overload under unbalanced loading conditions. In the second approach (Chapter 7), a hierarchical control scheme, consisting of primary (modified V-I droop) and distributed secondary control levels is introduced to mitigate harmonic distortions and prevent overcurrent stresses under nonlinear and unbalanced loading conditions. Finally, the conclusions and possible future work are addressed in Chapter 8