36,825 research outputs found

    Does a Novice Technician Produce Results Similar to That of an Experienced DXA Technician When Assessing Body Composition and Bone Mineral Density?

    Get PDF
    Dual energy X-ray absorptiometry is a commonly used clinical assessment tool for body composition and bone mineral density, which is gaining popularity in athletic cohorts. Results from body composition scans are useful for athletic populations to track training and nutritional interventions, whilst bone mineral density scans are valuable for athletes at risk of developing stress fractures due to low bone mineral density. However, no research has ascertained if a novice technician (accredited but not experienced) could produce similar results to an experienced technician. Two groups of recreational athletes were scanned, one by an experienced technician, one by a novice technician. All participants were scanned twice with repositioning between scans. The experienced technician\u27s reliability (ICC 0.989 - 0.998, percentage change in mean -0.01 - 0.10), precision (typical error as CV% 0.01 to 0.47. standard error of measurement percentage 0.61% - 1.39%) and sensitivity to change (smallest real difference percentage 1.70% - 3.85%) were similar, however superior, to those of the novice technician. The novice technician results were: reliability (ICC 0.985 - 0.997, percentage change in mean -0.03 - 0.23), precision (typical error as CV% 0.03 - 0.75%, standard error of measurement percentage 1.06% - 2.12%) and sensitivity to change (smallest real difference percentage 2.73% - 5.86%). Extensive experience whilst valuable is not a necessary requirement to produce quality results when undertaking whole body dual energy X-ray absorptiometry scanning

    Analytical techniques of pilot scanning behavior and their application

    Get PDF
    The state of the art of oculometric data analysis techniques and their applications in certain research areas such as pilot workload, information transfer provided by various display formats, crew role in automated systems, and pilot training are documented. These analytical techniques produce the following data: real-time viewing of the pilot's scanning behavior, average dwell times, dwell percentages, instrument transition paths, dwell histograms, and entropy rate measures. These types of data are discussed, and overviews of the experimental setup, data analysis techniques, and software are presented. A glossary of terms frequently used in pilot scanning behavior and a bibliography of reports on related research sponsored by NASA Langley Research Center are also presented

    Decreased dopamine activity predicts relapse in methamphetamine abusers.

    Get PDF
    Studies in methamphetamine (METH) abusers showed that the decreases in brain dopamine (DA) function might recover with protracted detoxification. However, the extent to which striatal DA function in METH predicts recovery has not been evaluated. Here we assessed whether striatal DA activity in METH abusers is associated with clinical outcomes. Brain DA D2 receptor (D2R) availability was measured with positron emission tomography and [(11)C]raclopride in 16 METH abusers, both after placebo and after challenge with 60 mg oral methylphenidate (MPH) (to measure DA release) to assess whether it predicted clinical outcomes. For this purpose, METH abusers were tested within 6 months of last METH use and then followed up for 9 months of abstinence. In parallel, 15 healthy controls were tested. METH abusers had lower D2R availability in caudate than in controls. Both METH abusers and controls showed decreased striatal D2R availability after MPH and these decreases were smaller in METH than in controls in left putamen. The six METH abusers who relapsed during the follow-up period had lower D2R availability in dorsal striatum than in controls, and had no D2R changes after MPH challenge. The 10 METH abusers who completed detoxification did not differ from controls neither in striatal D2R availability nor in MPH-induced striatal DA changes. These results provide preliminary evidence that low striatal DA function in METH abusers is associated with a greater likelihood of relapse during treatment. Detection of the extent of DA dysfunction may be helpful in predicting therapeutic outcomes

    B.O.G.G.L.E.S.: Boundary Optical GeoGraphic Lidar Environment System

    Get PDF
    The purpose of this paper is to describe a pseudo X-ray vision system that pairs a Lidar scanner with a visualization device. The system as a whole is referred to as B.O.G.G.L.E.S. There are several key factors that went into the development of this system and the background information and design approach are thoroughly described. B.O.G.G.L.E.S functionality is depicted through the use of design constraints and the analysis of test results. Additionally, many possible developments for B.O.G.G.L.E.S are proposed in the paper. This indicates that there are various avenues of improvement for this project that could be implemented in the future

    Use of sensitivity analysis to predict pilot performance as a function of different displays

    Get PDF
    A technique for objectively evaluating different displays by sensitivity analysis is described. First, the mathematical model used to analyze static displays is developed. The technique is based on formulating functional relationships between the state variables and the variables observable in the display. The matrix of the partial derivatives of the display variables with respect to the state variables, together with the observer's acuity function, is used to calculate expected errors in the state vector estimation. The technique is expanded by the use of Kalman filtering to process a time series of observation vectors. This provides a tool for analyzing displays of dynamic processes by means of a dynamic display evaluation computer program. Results are reported using this program to simulate an Instrument Landing System approach
    • …
    corecore