9,394 research outputs found

    Examination of silver-graphite lithographically printed resistive strain sensors

    Get PDF
    This paper reports the design and manufacture of three differing types of resistive strain sensitive structures fabricated using the Conductive Lithographic Film (CLF) printing process. The structures, utilising two inks prepared with silver and graphite particulates as the conductive phase, have been analysed to determine electrical and mechanical properties with respect to strain, temperature and humidity when deposited on four alternative substrate materials (GlossArt, PolyArt, Teslin and Melinex)

    Respiration rate and volume measurements using wearable strain sensors.

    Get PDF
    Current methods for continuous respiration monitoring such as respiratory inductive or optoelectronic plethysmography are limited to clinical or research settings; most wearable systems reported only measures respiration rate. Here we introduce a wearable sensor capable of simultaneously measuring both respiration rate and volume with high fidelity. Our disposable respiration sensor with a Band-Aid© like formfactor can measure both respiration rate and volume by simply measuring the local strain of the ribcage and abdomen during breathing. We demonstrate that both metrics are highly correlated to measurements from a medical grade continuous spirometer on participants at rest. Additionally, we also show that the system is capable of detecting respiration under various ambulatory conditions. Because these low-powered piezo-resistive sensors can be integrated with wireless Bluetooth units, they can be useful in monitoring patients with chronic respiratory diseases in everyday settings

    Silicon strain sensors enable pressure measurement at cryogenic temperatures

    Get PDF
    Miniature pressure transducers with diffused, heavily doped silicon strain-gage sensor elements, operates over a wide temperature range. Small thermal mass combined with close coupling between a metallic diaphragm and sensor elements minimizes sensitivity to temperature transients

    Insulated-gate field-effect transistor strain sensor

    Get PDF
    Strain sensors that can be switched on and off were fabricated from p-channel IGFET on thin filament n-type silicon crystals with silicon dioxide layer sputtered over transistor for passivation. Applications include integration with microelectronic circuits for multiplexing

    Nano strain-amplifier: making ultra-sensitive piezoresistance in nanowires possible without the need of quantum and surface charge effects

    Get PDF
    This paper presents an innovative nano strain-amplifier employed to significantly enhance the sensitivity of piezoresistive strain sensors. Inspired from the dogbone structure, the nano strain-amplifier consists of a nano thin frame released from the substrate, where nanowires were formed at the centre of the frame. Analytical and numerical results indicated that a nano strain-amplifier significantly increases the strain induced into a free standing nanowire, resulting in a large change in their electrical conductance. The proposed structure was demonstrated in p-type cubic silicon carbide nanowires fabricated using a top down process. The experimental data showed that the nano strain-amplifier can enhance the sensitivity of SiC strain sensors at least 5.4 times larger than that of the conventional structures. This result indicates the potential of the proposed strain-amplifier for ultra-sensitive mechanical sensing applications.Comment: 4 pages, 5 figure

    Strain monitoring.

    Get PDF
    This chapter provides an overview of the use of strain sensors for structural health monitoring. Compared to acceleration-based sensors, strain sensors can measure the deformation of a structure at very low frequencies (up to DC) and enable the measurement of ultrasonic responses. Many existing SHM methods make use of strain measurement data. Furthermore, strain sensors can be easily integrated in (aircraft) structures. This chapter discusses the working principle of traditional strain gauges (Sect. 8.1) and different types of optical fiber sensors (Sect. 8.2). The installation requirements of strain sensors and the required hardware for reading out sensors are provided. We will also give an overview of the advantages and the limitations of commonly used strain sensors. Finally, we will present an overview of the applications of strain sensors for structural health monitoring in the aeronautics field

    Wearable and Stretchable Strain Sensors: Materials, Sensing Mechanisms, and Applications

    Get PDF
    Recent advances in the design and implementation of wearable resistive, capacitive, and optical strain sensors are summarized herein. Wearable and stretchable strain sensors have received extensive research interest due to their applications in personalized healthcare, human motion detection, human–machine interfaces, soft robotics, and beyond. The disconnection of overlapped nanomaterials, reversible opening/closing of microcracks in sensing films, and alteration of the tunneling resistance have been successfully adopted to develop high-performance resistive-type sensors. On the other hand, the sensing behavior of capacitive-type and optical strain sensors is largely governed by their geometrical changes under stretching/releasing cycles. The sensor design parameters, including stretchability, sensitivity, linearity, hysteresis, and dynamic durability, are comprehensively discussed. Finally, the promising applications of wearable strain sensors are highlighted in detail. Although considerable progress has been made so far, wearable strain sensors are still in their prototype stage, and several challenges in the manufacturing of integrated and multifunctional strain sensors should be yet tackled
    corecore