15,122 research outputs found
Recommended from our members
S-Hybrid Step-Down DC-DC Converter-Analysis of Operation and Design Considerations
Recommended from our members
The road to fully integrated DC-DC conversion via the switched-capacitor approach
This paper provides a perspective on progress toward realization of efficient, fully integrated dc-dc conversion and regulation functionality in CMOS platforms. In providing a comparative assessment between the inductor-based and switched-capacitor approaches, the presentation reviews the salient features in effectiveness in utilization of switch technology and in use and implementation of passives. The analytical conclusions point toward the strong advantages of the switched-capacitor (SC) approach with respect to both switch utilization and much higher energy densities of capacitors versus inductors. The analysis is substantiated with a review of recently developed and published integrated dc-dc converters of both the inductor-based and SC types. © 2012 IEEE
Issues concerning centralized versus decentralized power deployment
The results of a study of proposed lunar base architectures to identify issues concerning centralized and decentralized power system deployment options are presented. The power system consists of the energy producing system (power plant), the power conditioning components used to convert the generated power into the form desired for transmission, the transmission lines that conduct this power from the power sources to the loads, and the primary power conditioning hardware located at the user end. Three power system architectures, centralized, hybrid, and decentralized, were evaluated during the course of this study. Candidate power sources were characterized with respect to mass and radiator area. Two electrical models were created for each architecture to identify the preferred method of power transmission, dc or ac. Each model allowed the transmission voltage level to be varied at assess the impact on power system mass. The ac power system models also permitted the transmission line configurations and placements to determine the best conductor construction and installation location. Key parameters used to evaluate each configuration were power source and power conditioning component efficiencies, masses, and radiator areas; transmission line masses and operating temperatures; and total system mass
Phase 1 of the near term hybrid passenger vehicle development program
In order to meet project requirements and be competitive in the 1985 market, the proposed six-passenger vehicle incorporates a high power type Ni-Zn battery, which by making electric-only traction possible, permits the achievement of an optimized control strategy based on electric-only traction to a set battery depth of discharge, followed by hybrid operation with thermal primary energy. This results in a highly efficient hybrid propulsion subsystem. Technical solutions are available to contain energy waste by reducing vehicle weight, rolling resistance, and drag coefficient. Reproaching new 1985 full size vehicles of the conventional type with hybrids of the proposed type would result in a U.S. average gasoline saving per vehicle of 1,261 liters/year and an average energy saving per vehicle of 27,133 MJ/year
Reactive power minimization of dual active bridge DC/DC converter with triple phase shift control using neural network
Reactive power flow increases dual active bridge (DAB) converter RMS current leading to an increase in conduction losses especially in high power applications. This paper proposes a new optimized triple phase shift (TPS) switching algorithm that minimizes the total reactive power of the converter. The algorithm iteratively searches for TPS control variables that satisfy the desired active power flow while selecting the operating mode with minimum reactive power consumption. This is valid for the whole range of converter operation. The iterative algorithm is run offline for the entire active power range (-1pu to 1pu) and the resulting data is used to train an open loop artificial neural network controller to reduce computational time and memory allocation necessary to store the data generated. To validate the accuracy of the proposed controller, a 500-MW 300kV/100kV DAB model is simulated in Matlab/Simulink, as a potential application for DAB in DC grids
STUDY OF FULLY-INTEGRATED LOW-DROPOUT REGULATORS
Department of Electrical EngineeringThis thesis focuses on the introduction of fully-integrated low-dropout regulators (LDOs). Recently, for the mobile and internet-of-things applications, the level of integration is getting higher. LDOs get popular in integrated circuit design including functions such as reducing switching ripples from high-efficiency regulators, cancelling spurs from other loads, and giving different supply voltages to loads. In accordance with load applications, choosing proper LDOs is important. LDOs can be classified by the types of power MOSEFT, the topologies of error amplifier, and the locations of dominant pole. Analog loads such as voltage-controlled oscillators and analog-to-digital converters need LDOs that have high power-supply-rejection-ratio (PSRR), high accuracy, and low noise. Digital loads such as DRAM and CPU need fast transient response, a wide range of load current providable LDOs. As an example, we present the design procedure of a fully-integrated LDO that obtains the desired PSRR. In analog LDOs, we discuss advanced techniques such as local positive feedback loop and zero path that can improve stability and PSRR performance. In digital LDOs, the techniques to improve transient response are introduced. In analog-digital hybrid LDOs, to achieve both fast transient and high PSRR performance in a fully-integrated chip, how to optimally combine analog and digital LDOs is considered based on the characteristics of each LDO type. The future work is extracted from the considerations and limitations of conventional techniques.clos
Experimental Test bed to De-Risk the Navy Advanced Development Model
This paper presents a reduced scale demonstration test-bed at the University of Texas’ Center for Electromechanics (UT-CEM) which is well equipped to support the development and assessment of the anticipated Navy Advanced Development Model (ADM). The subscale ADM test bed builds on collaborative power management experiments conducted as part of the Swampworks Program under the US/UK Project Arrangement as well as non-military applications. The system includes the required variety of sources, loads, and controllers as well as an Opal-RT digital simulator. The test bed architecture is described and the range of investigations that can be carried out on it is highlighted; results of preliminary system simulations and some initial tests are also provided. Subscale ADM experiments conducted on the UT-CEM microgrid can be an important step in the realization of a full-voltage, full-power ADM three-zone demonstrator, providing a test-bed for components, subsystems, controls, and the overall performance of the Medium Voltage Direct Current (MVDC) ship architecture.Center for Electromechanic
System configuration, fault detection, location, isolation and restoration: a review on LVDC Microgrid protections
Low voltage direct current (LVDC) distribution has gained the significant interest of research due to the advancements in power conversion technologies. However, the use of converters has given rise to several technical issues regarding their protections and controls of such devices under faulty conditions. Post-fault behaviour of converter-fed LVDC system involves both active converter control and passive circuit transient of similar time scale, which makes the protection for LVDC distribution significantly different and more challenging than low voltage AC. These protection and operational issues have handicapped the practical applications of DC distribution. This paper presents state-of-the-art protection schemes developed for DC Microgrids. With a close look at practical limitations such as the dependency on modelling accuracy, requirement on communications and so forth, a comprehensive evaluation is carried out on those system approaches in terms of system configurations, fault detection, location, isolation and restoration
Nonlinear Analysis and Control of Interleaved Boost Converter Using Real-Time Cycle to Cycle Variable Slope Compensation
Switched-mode power converters are inherently nonlinear and piecewise smooth systems that may exhibit a series of undesirable operations that can greatly reduce the converter's efficiency and lifetime. This paper presents a nonlinear analysis technique to investigate the influence of system parameters on the stability of interleaved boost converters. In this approach, Monodromy matrix that contains all the comprehensive information of converter parameters and control loop can be employed to fully reveal and understand the inherent nonlinear dynamics of interleaved boost converters, including the interaction effect of switching operation. Thereby not only the boundary conditions but also the relationship between stability margin and the parameters given can be intuitively studied by the eigenvalues of this matrix. Furthermore, by employing the knowledge gained from this analysis, a real-Time cycle to cycle variable slope compensation method is proposed to guarantee a satisfactory performance of the converter with an extended range of stable operation. Outcomes show that systems can regain stability by applying the proposed method within a few time periods of switching cycles. The numerical and analytical results validate the theoretical analysis, and experimental results verify the effectiveness of the proposed approach
Urban and extra-urban hybrid vehicles: a technological review
Pollution derived from transportation systems is a worldwide, timelier issue than ever. The abatement actions of harmful substances in the air are on the agenda and they are necessary today to safeguard our welfare and that of the planet. Environmental pollution in large cities is approximately 20% due to the transportation system. In addition, private traffic contributes greatly to city pollution. Further, “vehicle operating life” is most often exceeded and vehicle emissions do not comply with European antipollution standards. It becomes mandatory to find a solution that respects the environment and, realize an appropriate transportation service to the customers. New technologies related to hybrid –electric engines are making great strides in reducing emissions, and the funds allocated by public authorities should be addressed. In addition, the use
(implementation) of new technologies is also convenient from an economic point of view. In fact, by implementing the use of hybrid vehicles, fuel consumption can be reduced. The different hybrid configurations presented refer to such a series architecture, developed by the researchers and Research and Development groups. Regarding energy flows, different strategy logic or vehicle management units have been illustrated. Various configurations and vehicles were studied by simulating different driving cycles, both European approval and homologation and customer ones (typically municipal and university). The simulations have provided guidance on the optimal proposed configuration and information on the component to be used
- …