1,134 research outputs found

    PrĂ€diktive Regelung und Finite-Set-Beobachter fĂŒr Windgeneratoren mit variabler Drehgeschwindigkeit

    Get PDF
    This dissertation presents several model predictive control (MPC) techniques and finite-position-set observers (FPSOs) for permanent-magnet synchronous generators and doubly-fed induction generators in variable-speed wind turbines. The proposed FPSOs are novel ones and based on the concept of finite-control-set MPC. Then, the problems of the MPC techniques like sensitivity to variations of the model parameters and others are investigated and solved in this work.Die vorliegende Dissertation stellt mehrere unterschiedliche Verfahren der modellprĂ€diktiven Regelung (MPC) und so genannte Finite-Position-Set-Beobachter (FPSO) sowohl fĂŒr Synchrongeneratoren mit Permanentmagneterregung als auch fĂŒr doppelt gespeiste Asynchrongeneratoren in Windkraftanlagen mit variabler Drehzahl vor und untersucht diese. FĂŒr die Beobachter (FPSO) wird ein neuartiger Ansatz vorgestellt, der auf dem Konzept der Finite-Control-Set-MPC basiert. Außerdem werden typische Eigenschaften der MPC wie beispielsweise die AnfĂ€lligkeit gegenĂŒber Parameterschwankungen untersucht und kompensiert

    Improved direct torque control using Kalman filter: application to a doubly-fed machine

    Get PDF
    Direct Torque Control (DTC) has been extensively researched and applied during the last two decades. However, it has only first been applied to the Brushless Doubly Fed Reluctance Machine (BDFRM) a few years ago in its basic form inheriting its intrinsic flux estimation problems that propagate throughout the algorithm and hence compromise the DTC performance. In this paper, we propose the use of Kalman Filter (KF) as an alternative to improve the estimation and consequently the control performance of the DTC. The KF is designed around a nominal model, but is shown to be reliable over the whole operating range of the BDFRM. Moreover, we use a modified robust exact differentiator based on Sliding Mode (SM) techniques to calculate the angular velocity from an angular position encoder. Computer simulations are meticulously designed to take into account real-world physical constraints and thus show illustrative supporting results as expected from an experimental setup

    Induction Motor Performance Improvement using Super Twisting SMC and Twelve Sector DTC

    Get PDF
    Induction motor (IM) direct torque control (DTC) is prone to a number of weaknesses, including uncertainty, external disturbances, and non-linear dynamics. Hysteresis controllers are used in the inner loops of this control method, whereas traditional proportional-integral (PI) controllers are used in the outer loop. A high-performance torque and speed system is consequently needed to assure a stable and reliable command that can tolerate such unsettled effects. This paper treats the design of a robust sensorless twelve-sector DTC of a three-phase IM. The speed controller is conceived based on high-order super-twisting sliding mode control with integral action (iSTSMC). The goal is to decrease the flux, torque, the current ripples that constitute the major conventional DTC drawbacks. The phase current ripples have been effectively reduced from 76.92% to 45.30% with a difference of 31.62%. A robust adaptive flux and speed observer-based fuzzy logic mechanism are inserted to get rid of the mechanical sensor. Satisfactory results have been got through simulations in MATLAB/Simulink under load disturbance. In comparison to a conventional six-sector DTC, the suggested technique has a higher performance and lower distortion rate

    Dynamic Performance Analysis of a Five-Phase PMSM Drive Using Model Reference Adaptive System and Enhanced Sliding Mode Observer

    Get PDF
    This paper aims to evaluate the dynamic performance of a five-phase PMSM drive using two different observers: sliding mode (SMO) and model reference adaptive system (MRAS). The design of the vector control for the drive is firstly introduced in details to visualize the proper selection of speed and current controllers’ gains, then the construction of the two observers are presented. The stability check for the two observers are also presented and analyzed, and finally the evaluation results are presented to visualize the features of each sensorless technique and identify the advantages and shortages as well. The obtained results reveal that the de-signed SMO exhibits better performance and enhanced robustness compared with the MRAS under different operating conditions. This fact is approved through the obtained results considering a mismatch in the values of stator resistance and stator inductance as well. Large deviation in the values of estimated speed and rotor position are observed under MRAS, and this is also accompanied with high speed and torque oscillations

    Self-adaptive high-frequency injection based sensorless control for interior permanent magnet synchronous motor drives \u2020

    Get PDF
    Abstract: An auto-tuning and self-adaptation procedure for High Frequency Injection (HFI) based position and speed estimation algorithms in Interior Permanent Magnet Synchronous Motor (IPMSM) drives is proposed in this paper. Analytical developments show that, using conventional approaches, the dynamics of the high-frequency tracking loop varies with differential inductances, which in turn depend on the machine operating point. On-line estimation and adaptation of the small signal gain of the loop is proposed here, allowing accurate auto-tuning of the sensorless control scheme which does not rely on a priori knowledge of the machine parameters. On-line adaptation of Phase-Locked Loop (PLL) gains and of the injected voltage magnitude is also possible, leading to important advantages from the performance, loss and acoustic point of view. The theoretical basis of the method has been introduced first and the main concept demonstrated by means of simulations. Implementation has been carried out using the hardware of a commercial industrial drive and two Interior Permanent Magnet Synchronous Motors, namely a prototype and an off-the-shelf machine. Experimental tests demonstrate the feasibility and effectiveness of the proposal

    Self-Adaptive High-Frequency Injection Based Sensorless Control for Interior Permanent Magnet Synchronous Motor Drives

    Get PDF
    open5openKumar, Piyush; Bottesi, Omar; Calligaro, Sandro; Alberti, Luigi; Petrella, RobertoKumar, Piyush; Bottesi, Omar; Calligaro, Sandro; Alberti, Luigi; Petrella, Robert

    Multi-Sampled Current Control of Grid-Connected Voltage Source Converters

    Get PDF

    Continuous dynamic sliding mode control strategy of PWM based voltage source inverter under load variations

    Get PDF
    For closed-loop controlled DC-AC inverter system, the performance is highly influenced by load variations and online current measurement. Any variation in the load will introduce unwanted periodic error at the inverter output voltage. In addition, when the current sensor is in faulty condition, the current measurement will be imprecise and the designed feedback control law will be ineffective. In this paper, a sensorless continuous sliding mode control (SMC) scheme has been proposed to address these issues. The chattering effect due to the discontinuous switching nature of SMC has been attenuated by designing a novel boundary-based saturation function where the selection of the thickness of boundary is dependent to the PWM signal generation of the inverter. In order to remove the dependency on the current sensor, a particle swarm optimization(PSO) based modified observer is proposed to estimate the inductor current in which the observer gains are optimized using PSO by reducing the estimation errors cost function. The proposed dynamic smooth SMC algorithm has been simulated in MATLAB Simulink environment for 0.2-kVA DC-AC inverter and the results exhibit rapid dynamic response with a steady-state error of 0.4V peak-to-peak voltage under linear and nonlinear load perturbations. The total harmonic distortion (THD) is also reduced to 0.20% and 1.14% for linear and non-linear loads, respectively
    • 

    corecore