319 research outputs found

    Design and control of soft rehabilitation robots actuated by pneumatic muscles: State of the art

    Get PDF
    Robot-assisted rehabilitation has become a new mainstream trend for the treatment of stroke patients with movement disability. Pneumatic muscle (PM) is one of the most promising actuators for rehabilitation robots, due to its inherent compliance and safety features. In this paper, we conduct a systematic review on the soft rehabilitation robots driven by pneumatic muscles. This review discusses up to date mechanical structures and control strategies for PMs-actuated rehabilitation robots. A variety of state-of-the-art soft rehabilitation robots are classified and reviewed according to the actuation configurations. Special attentions are paid to control strategies under different mechanical designs, with advanced control approaches to overcome PM’s highly nonlinear and time-varying behaviors and to enhance the adaptability to different patients. Finally, we analyze and highlight the current research gaps and the future directions in this field, which is potential for providing a reliable guidance on the development of advanced soft rehabilitation robots

    Knee Exoskeletons Design Approaches to Boost Strength Capability: A Review

    Get PDF
    Exoesqueleto para incrementar la fuerza en las rodillasThere are different devices to increase the strength capacity of people with walking problems. These devices can be classified into exoskeletons, orthotics, and braces. This review aims to identify the state of the art in the design of these medical devices, based on an analysis of patents and literature. However, there are some difficulties in processing the records due to the lack of filters and standardization in the names, generating discrepancies between the search engines, among others. Concerning the patents, 74 patents were analyzed using search engines such as Google Patents, Derwent, The Lens, Patentscope, and Espacenet over the past ten years. A bibliometric analysis was performed using 63 scientific reports from Web of Science and The Lens in the same period for scientific communications. The results show a trend to use the mechanical design of exoskeletons based on articulated rigid structures and elements that provide force to move the structure. These are generally two types: (a) elastic elements and (b) electromechanical elements. The United States accounts for 32% of the technological patents reviewed. The results suggest that the use of exoskeletons or orthoses customized to the users’ needs will continue to increase over the years due to the worldwide growth in disability, particularly related to mobility difficulties and technologies related to the combined use of springs and actuators

    Command Filter Backstepping Sliding Model Control for Lower-Limb Exoskeleton

    Get PDF
    A command filter adaptive fuzzy backstepping control strategy is proposed for lower-limb assisting exoskeleton. Firstly, the human-robot model is established by taking the human body as a passive part, and a coupling torque is introduced to describe the interaction between the exoskeleton and human leg. Then, Vicon motion capture system is employed to obtain the reference trajectory. For the purpose of obviating the “explosion of complexity” in conventional backstepping, a second-order command filter is introduced into the sliding mode control strategy. The fuzzy logic systems (FLSs) are also applied to handle with the chattering problem by estimating the uncertainties and disturbances. Furthermore, the stability of the closed-loop system is proved based on the Lyapunov theory. Finally, simulation results are presented to illustrate the effectiveness of the control strategy

    Genetic Algorithms Based Approach for Designing Spring Brake Orthosis – Part Ii: Control of FES Induced Movement

    Get PDF
    Spring brake orthotic swing phase for paraplegic gait is initiated through releasing the brake on the knee mounted with a torsion spring. The stored potential energy in the spring, gained from the previous swing phase, is solely responsible for swing phase knee flexion. Hence the later part of the SBO operation, functional electrical stimulation (FES) assisted extension movement of the knee has to serve an additional purpose of restoring the spring potential energy on the fly. While control of FES induced movement as such is often a challenging task, a torsion spring, being antagonistically paired up with the muscle actuator, as in spring brake orthosis (SBO), only adds to the challenge. Two new schemes are proposed for the control of FES induced knee extension movement in SBO assisted swing phase. Even though the control schemes are closed-loop in nature, special attention is paid to accommodate the natural dynamics of the mechanical combination being controlled (the leg segment) as a major role playing feature. The schemes are thus found to be immune from some drawbacks associated with both closed-loop tracking as well as open-loop control of FES induced movement. A leg model including the FES knee joint model of the knee extensor muscle vasti along with the passive properties is used in the simulation. The optimized parameters for the SBO spring are obtained from the earlier part of this work. Genetic algorithm (GA) and multi-objective GA (MOGA) are used to optimize the parameters associated with the control schemes with minimum fatigue as one of the control objectives. The control schemes are evaluated in terms of three criteria based on their ability to cope with muscle fatigue

    Advancements in Sensor Technologies and Control Strategies for Lower-Limb Rehabilitation Exoskeletons: A Comprehensive Review

    Get PDF
    Lower-limb rehabilitation exoskeletons offer a transformative approach to enhancing recovery in patients with movement disorders affecting the lower extremities. This comprehensive systematic review delves into the literature on sensor technologies and the control strategies integrated into these exoskeletons, evaluating their capacity to address user needs and scrutinizing their structural designs regarding sensor distribution as well as control algorithms. The review examines various sensing modalities, including electromyography (EMG), force, displacement, and other innovative sensor types, employed in these devices to facilitate accurate and responsive motion control. Furthermore, the review explores the strengths and limitations of a diverse array of lower-limb rehabilitation-exoskeleton designs, highlighting areas of improvement and potential avenues for further development. In addition, the review investigates the latest control algorithms and analysis methods that have been utilized in conjunction with these sensor systems to optimize exoskeleton performance and ensure safe and effective user interactions. By building a deeper understanding of the diverse sensor technologies and monitoring systems, this review aims to contribute to the ongoing advancement of lower-limb rehabilitation exoskeletons, ultimately improving the quality of life for patients with mobility impairments

    Synchronous Position and Compliance Regulation on a Bi-Joint Gait Exoskeleton Driven by Pneumatic Muscles

    Get PDF
    A previously developed pneumatic muscles’ (PMs) actuated gait exoskeleton (with only knee joint) has been demonstrated in achieving appropriate actuation torque, range of motion (ROM), and control bandwidth for task-specific gait training. While the adopted multi-input–multi-output (MIMO) sliding mode (SM) strategy has preliminarily implemented simultaneous control of the exoskeleton’s angular trajectory and compliance, its efficacy with human users during gait cycles has not been investigated. This article presents an improved bi-joint gait rehabilitation exoskeleton (BiGREX) with integrated human hip and knee joints. The results with 12 healthy subjects demonstrated that the system’s compliance can be effectively adjusted while guiding the subjects walking in predefined trajectories. Note to Practitioners —This article was motivated by achieving compliant interaction between PM-actuated exoskeletons and human when conducting task-specific gait training. Due to the intrinsic nonlinearity of PM, it is challenging to establish a mathematical model to precisely predict real-time compliance of the powered joints. This article suggests a new strategy that adopts the average pressure of flexor and extensor PMs as the feedback to synchronously realize the joint position control and compliance regulation. A novel experimental approach was adopted to validate the system capability on adjusting the compliance from human users’ perception. This article provides a new insight between the controlled PM pressure and the desired joint compliance, which would be essential for the future design of PM-actuated exoskeletons

    Soft Actuators and Robotic Devices for Rehabilitation and Assistance

    Get PDF
    Soft actuators and robotic devices have been increasingly applied to the field of rehabilitation and assistance, where safe human and machine interaction is of particular importance. Compared with their widely used rigid counterparts, soft actuators and robotic devices can provide a range of significant advantages; these include safe interaction, a range of complex motions, ease of fabrication and resilience to a variety of environments. In recent decades, significant effort has been invested in the development of soft rehabilitation and assistive devices for improving a range of medical treatments and quality of life. This review provides an overview of the current state-of-the-art in soft actuators and robotic devices for rehabilitation and assistance, in particular systems that achieve actuation by pneumatic and hydraulic fluid-power, electrical motors, chemical reactions and soft active materials such as dielectric elastomers, shape memory alloys, magnetoactive elastomers, liquid crystal elastomers and piezoelectric materials. Current research on soft rehabilitation and assistive devices is in its infancy, and new device designs and control strategies for improved performance and safe human-machine interaction are identified as particularly untapped areas of research. Finally, insights into future research directions are outlined

    Coupling Disturbance Compensated MIMO Control of Parallel Ankle Rehabilitation Robot Actuated by Pneumatic Muscles

    Get PDF
    To solve the poor compliance and safety problems in current rehabilitation robots, a novel two-degrees-offreedom (2-DOF) soft ankle rehabilitation robot driven by pneumatic muscles (PMs) is presented, taking advantages of the PM’s inherent compliance and the parallel structure’s high stiffness and payload capacity. However, the PM’s nonlinear, time-varying and hysteresis characteristics, and the coupling interference from parallel structure, as well as the unpredicted disturbance caused by arbitrary human behavior all raise difficulties in achieving high-precision control of the robot. In this paper, a multi-input-multi-output disturbance compensated sliding mode controller (MIMO-DCSMC) is proposed to tackle these problems. The proposed control method can tackle the un-modeled uncertainties and the coupling interference existed in multiple PMs’ synchronous movement, even with the subject’s participation. Experiment results on a healthy subject confirmed that the PMs-actuated ankle rehabilitation robot controlled by the proposed MIMO-DCSMC is able to assist patients to perform high-accuracy rehabilitation tasks by tracking the desired trajectory in a compliant manner
    corecore