17 research outputs found

    Quantitative microwave imaging based on a huber regularization

    Get PDF
    Reconstruction of inhomogeneous dielectric objects from microwave scattering by means of quantitative microwave tomography is a nonlinear, ill-posed inverse problem. In this paper, we employ the Huber function as a robust regularization approach for this challenging problem. The resulting reconstructions both in 2D and 3D from sparse data points for piecewise constant objects are encouraging. The reconstructions of more complex permittivity profiles from breast phantom data indicate potential for use in biomedical imaging

    Spatial priors for tomographic reconstructions from limited data

    Get PDF
    Tomografie is het reconstrueren van het inwendige van een object a.d.h.v externe metingen, b.v. beelden verkregen met X-stralen of microgolven. Deze thesis bekijkt de specifieke aspecten van microgolftomografie en magnetische resonantie beeldvorming (Magnetic Resonance Imaging – MRI); beide technieken zijn onschadelijk voor de mens. Terwijl het gebruik van MRI wijdverspreid is voor veel klinische toepassingen, is microgolftomografie nog niet in klinisch gebruik ondanks zijn potentiële voordelen. Door de lage kost en draagbaarheid van de toestellen is het een waardevolle aanvulling aan het assortiment

    Ultrasound tomography using pyroelectric and piezoelectric sensors

    Get PDF
    Acoustic absorption is one of several quantities which can differentiate healthy breast tissue from cancerous tissue. In order to accurately quantify the acoustic absorption, the sensor system must be able to accurately distinguish acoustic power loss due to absorption from other modes of attenuation. Traditional piezoelectric sensors are susceptible to phase-cancellation artifacts due to their directional signal response, and thus pyroelectric ultrasound sensors, which have a much flatter directional response, have been suggested as an alternate measurement device for improved absorption reconstructions in ultrasound tomography (UST). In this thesis we investigate the use of pyroelectric phase-insensitive sensors in UST — the thesis is divided into two parts. In the first part we present a model for a pyroelectric ultrasound sensor and investigate its directional response and sensitivity properties. The model’s time-series response and directional response are compared to real-world measurements to confirm accuracy. The second part focuses on the inverse problem aspect of ultrasound tomography, where we consider various reconstruction methods and sensor geometries to determine which situations can benefit from phase-insensitive data for acoustic absorption reconstruction. Reconstructions for both phase-insensitive as well as phase-sensitive sensors are analysed, with future work considerations for combined sensor systems

    Elevation and Deformation Extraction from TomoSAR

    Get PDF
    3D SAR tomography (TomoSAR) and 4D SAR differential tomography (Diff-TomoSAR) exploit multi-baseline SAR data stacks to provide an essential innovation of SAR Interferometry for many applications, sensing complex scenes with multiple scatterers mapped into the same SAR pixel cell. However, these are still influenced by DEM uncertainty, temporal decorrelation, orbital, tropospheric and ionospheric phase distortion and height blurring. In this thesis, these techniques are explored. As part of this exploration, the systematic procedures for DEM generation, DEM quality assessment, DEM quality improvement and DEM applications are first studied. Besides, this thesis focuses on the whole cycle of systematic methods for 3D & 4D TomoSAR imaging for height and deformation retrieval, from the problem formation phase, through the development of methods to testing on real SAR data. After DEM generation introduction from spaceborne bistatic InSAR (TanDEM-X) and airborne photogrammetry (Bluesky), a new DEM co-registration method with line feature validation (river network line, ridgeline, valley line, crater boundary feature and so on) is developed and demonstrated to assist the study of a wide area DEM data quality. This DEM co-registration method aligns two DEMs irrespective of the linear distortion model, which improves the quality of DEM vertical comparison accuracy significantly and is suitable and helpful for DEM quality assessment. A systematic TomoSAR algorithm and method have been established, tested, analysed and demonstrated for various applications (urban buildings, bridges, dams) to achieve better 3D & 4D tomographic SAR imaging results. These include applying Cosmo-Skymed X band single-polarisation data over the Zipingpu dam, Dujiangyan, Sichuan, China, to map topography; and using ALOS L band data in the San Francisco Bay region to map urban building and bridge. A new ionospheric correction method based on the tile method employing IGS TEC data, a split-spectrum and an ionospheric model via least squares are developed to correct ionospheric distortion to improve the accuracy of 3D & 4D tomographic SAR imaging. Meanwhile, a pixel by pixel orbit baseline estimation method is developed to address the research gaps of baseline estimation for 3D & 4D spaceborne SAR tomography imaging. Moreover, a SAR tomography imaging algorithm and a differential tomography four-dimensional SAR imaging algorithm based on compressive sensing, SAR interferometry phase (InSAR) calibration reference to DEM with DEM error correction, a new phase error calibration and compensation algorithm, based on PS, SVD, PGA, weighted least squares and minimum entropy, are developed to obtain accurate 3D & 4D tomographic SAR imaging results. The new baseline estimation method and consequent TomoSAR processing results showed that an accurate baseline estimation is essential to build up the TomoSAR model. After baseline estimation, phase calibration experiments (via FFT and Capon method) indicate that a phase calibration step is indispensable for TomoSAR imaging, which eventually influences the inversion results. A super-resolution reconstruction CS based study demonstrates X band data with the CS method does not fit for forest reconstruction but works for reconstruction of large civil engineering structures such as dams and urban buildings. Meanwhile, the L band data with FFT, Capon and the CS method are shown to work for the reconstruction of large manmade structures (such as bridges) and urban buildings

    Large Scale Inverse Problems

    Get PDF
    This book is thesecond volume of a three volume series recording the "Radon Special Semester 2011 on Multiscale Simulation &amp Analysis in Energy and the Environment" that took placein Linz, Austria, October 3-7, 2011. This volume addresses the common ground in the mathematical and computational procedures required for large-scale inverse problems and data assimilation in forefront applications. The solution of inverse problems is fundamental to a wide variety of applications such as weather forecasting, medical tomography, and oil exploration. Regularisation techniques are needed to ensure solutions of sufficient quality to be useful, and soundly theoretically based. This book addresses the common techniques required for all the applications, and is thus truly interdisciplinary. This collection of survey articles focusses on the large inverse problems commonly arising in simulation and forecasting in the earth sciences

    Analysis and Modeling of Passive Stereo and Time-of-Flight Imaging

    Get PDF
    This thesis is concerned with the analysis and modeling of effects which cause errors in passive stereo and Time-of-Flight imaging systems. The main topics are covered in four chapters: I commence with a treatment of a system combining Time-of-Flight imaging with passive stereo and show how commonly used fusion models relate to the measurements of the individual modalities. In addition, I present novel fusion techniques capable of improving the depth reconstruction over those obtained separately by either modality. Next, I present a pipeline and uncertainty analysis for the generation of large amounts of reference data for quantitative stereo evaluation. The resulting datasets not only contain reference geometry, but also per pixel measures of reference data uncertainty. The next two parts deal with individual effects observed: Time-of-Flight cameras suffer from range ambiguity if the scene extends beyond a certain distance. I show that it is possible to extend the valid range by changing design parameters of the underlying measurement system. Finally, I present methods that make it possible to amend model violation errors in stereo due to reflections. This is done by means of modeling a limited level of light transport and material properties in the scene

    Inverse problems in medical ultrasound images - applications to image deconvolution, segmentation and super-resolution

    Get PDF
    In the field of medical image analysis, ultrasound is a core imaging modality employed due to its real time and easy-to-use nature, its non-ionizing and low cost characteristics. Ultrasound imaging is used in numerous clinical applications, such as fetus monitoring, diagnosis of cardiac diseases, flow estimation, etc. Classical applications in ultrasound imaging involve tissue characterization, tissue motion estimation or image quality enhancement (contrast, resolution, signal to noise ratio). However, one of the major problems with ultrasound images, is the presence of noise, having the form of a granular pattern, called speckle. The speckle noise in ultrasound images leads to the relative poor image qualities compared with other medical image modalities, which limits the applications of medical ultrasound imaging. In order to better understand and analyze ultrasound images, several device-based techniques have been developed during last 20 years. The object of this PhD thesis is to propose new image processing methods allowing us to improve ultrasound image quality using postprocessing techniques. First, we propose a Bayesian method for joint deconvolution and segmentation of ultrasound images based on their tight relationship. The problem is formulated as an inverse problem that is solved within a Bayesian framework. Due to the intractability of the posterior distribution associated with the proposed Bayesian model, we investigate a Markov chain Monte Carlo (MCMC) technique which generates samples distributed according to the posterior and use these samples to build estimators of the ultrasound image. In a second step, we propose a fast single image super-resolution framework using a new analytical solution to the l2-l2 problems (i.e., â„“2\ell_2-norm regularized quadratic problems), which is applicable for both medical ultrasound images and piecewise/ natural images. In a third step, blind deconvolution of ultrasound images is studied by considering the following two strategies: i) A Gaussian prior for the PSF is proposed in a Bayesian framework. ii) An alternating optimization method is explored for blind deconvolution of ultrasound
    corecore