774 research outputs found

    Evaluation of a calibration rig for stereo laparoscopes

    Get PDF
    BACKGROUND: Accurate camera and hand-eye calibration are essential to ensure high quality results in image guided surgery applications. The process must also be able to be undertaken by a non-expert user in a surgical setting. PURPOSE: This work seeks to identify a suitable method for tracked stereo laparoscope calibration within theatre. METHODS: A custom calibration rig, to enable rapid calibration in a surgical setting, was designed. The rig was compared against freehand calibration. Stereo reprojection, stereo reconstruction, tracked stereo reprojection and tracked stereo reconstruction error metrics were used to evaluate calibration quality. RESULTS: Use of the calibration rig reduced mean errors: reprojection (1.47mm [SD 0.13] vs 3.14mm [SD 2.11], p-value 1e-8), reconstruction (1.37px [SD 0.10] vs 10.10px [SD 4.54], p-value 6e-7) and tracked reconstruction (1.38mm [SD 0.10] vs 12.64mm [SD 4.34], p-value 1e-6) compared with freehand calibration. The use of a ChArUco pattern yielded slightly lower reprojection errors, while a dot grid produced lower reconstruction errors and was more robust under strong global illumination. CONCLUSION: The use of the calibration rig results in a statistically significant decrease in calibration error metrics, versus freehand calibration, and represents the preferred approach for use in the operating theatre. This article is protected by copyright. All rights reserved

    In vivo estimation of target registration errors during augmented reality laparoscopic surgery

    Get PDF
    PURPOSE: Successful use of augmented reality for laparoscopic surgery requires that the surgeon has a thorough understanding of the likely accuracy of any overlay. Whilst the accuracy of such systems can be estimated in the laboratory, it is difficult to extend such methods to the in vivo clinical setting. Herein we describe a novel method that enables the surgeon to estimate in vivo errors during use. We show that the method enables quantitative evaluation of in vivo data gathered with the SmartLiver image guidance system. METHODS: The SmartLiver system utilises an intuitive display to enable the surgeon to compare the positions of landmarks visible in both a projected model and in the live video stream. From this the surgeon can estimate the system accuracy when using the system to locate subsurface targets not visible in the live video. Visible landmarks may be either point or line features. We test the validity of the algorithm using an anatomically representative liver phantom, applying simulated perturbations to achieve clinically realistic overlay errors. We then apply the algorithm to in vivo data. RESULTS: The phantom results show that using projected errors of surface features provides a reliable predictor of subsurface target registration error for a representative human liver shape. Applying the algorithm to in vivo data gathered with the SmartLiver image-guided surgery system shows that the system is capable of accuracies around 12 mm; however, achieving this reliably remains a significant challenge. CONCLUSION: We present an in vivo quantitative evaluation of the SmartLiver image-guided surgery system, together with a validation of the evaluation algorithm. This is the first quantitative in vivo analysis of an augmented reality system for laparoscopic surgery

    The value of Augmented Reality in surgery — A usability study on laparoscopic liver surgery

    Get PDF
    Augmented Reality (AR) is considered to be a promising technology for the guidance of laparoscopic liver surgery. By overlaying pre-operative 3D information of the liver and internal blood vessels on the laparoscopic view, surgeons can better understand the location of critical structures. In an effort to enable AR, several authors have focused on the development of methods to obtain an accurate alignment between the laparoscopic video image and the pre-operative 3D data of the liver, without assessing the benefit that the resulting overlay can provide during surgery. In this paper, we present a study that aims to assess quantitatively and qualitatively the value of an AR overlay in laparoscopic surgery during a simulated surgical task on a phantom setup. We design a study where participants are asked to physically localise pre-operative tumours in a liver phantom using three image guidance conditions — a baseline condition without any image guidance, a condition where the 3D surfaces of the liver are aligned to the video and displayed on a black background, and a condition where video see-through AR is displayed on the laparoscopic video. Using data collected from a cohort of 24 participants which include 12 surgeons, we observe that compared to the baseline, AR decreases the median localisation error of surgeons on non-peripheral targets from 25.8 mm to 9.2 mm. Using subjective feedback, we also identify that AR introduces usability improvements in the surgical task and increases the perceived confidence of the users. Between the two tested displays, the majority of participants preferred to use the AR overlay instead of navigated view of the 3D surfaces on a separate screen. We conclude that AR has the potential to improve performance and decision making in laparoscopic surgery, and that improvements in overlay alignment accuracy and depth perception should be pursued in the future

    Metrics for Evaluating Surgical Microscope Usage During Myringotomy

    Get PDF
    Abstract Although teaching and learning surgical microscope manoeuvring is a fundamental step in middle ear surgical training, currently there is no objective method to teach or assess this skill. This thesis presents an experimental study designed to implement and test sets of metrics capable of numerically evaluating microscope manoeuvrability and qualitatively assessing surgical expertise of a subject during a middle ear surgery called myringotomy. The experiment involved performing a myringotomy on a fixed cadaveric ear. As participants, experienced ear-nose-throat (ENT) surgeons and ENT surgical residents were invited. While performing the procedure, their microscope manoeuvring motions were captured as translational and angular coordinates using an optical tracker. These data were analyzed in terms of motion path length, velocity, acceleration, jitter, manoeuvring volume, smoothness, rotation and time. Participants’ hand motion, body posture and microscopic view were also video recorded to qualitatively assess their surgical expertise. Several metrics were statistically identified as discriminatory. These metrics will be incorporated into a myringotomy surgical simulator to train ENT residents

    Medical SLAM in an autonomous robotic system

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This thesis addresses the ambitious goal of achieving surgical autonomy, through the study of the anatomical environment by Initially studying the technology present and what is needed to analyze the scene: vision sensors. A novel endoscope for autonomous surgical task execution is presented in the first part of this thesis. Which combines a standard stereo camera with a depth sensor. This solution introduces several key advantages, such as the possibility of reconstructing the 3D at a greater distance than traditional endoscopes. Then the problem of hand-eye calibration is tackled, which unites the vision system and the robot in a single reference system. Increasing the accuracy in the surgical work plan. In the second part of the thesis the problem of the 3D reconstruction and the algorithms currently in use were addressed. In MIS, simultaneous localization and mapping (SLAM) can be used to localize the pose of the endoscopic camera and build ta 3D model of the tissue surface. Another key element for MIS is to have real-time knowledge of the pose of surgical tools with respect to the surgical camera and underlying anatomy. Starting from the ORB-SLAM algorithm we have modified the architecture to make it usable in an anatomical environment by adding the registration of the pre-operative information of the intervention to the map obtained from the SLAM. Once it has been proven that the slam algorithm is usable in an anatomical environment, it has been improved by adding semantic segmentation to be able to distinguish dynamic features from static ones. All the results in this thesis are validated on training setups, which mimics some of the challenges of real surgery and on setups that simulate the human body within Autonomous Robotic Surgery (ARS) and Smart Autonomous Robotic Assistant Surgeon (SARAS) projects

    Medical SLAM in an autonomous robotic system

    Get PDF
    One of the main challenges for computer-assisted surgery (CAS) is to determine the intra-operative morphology and motion of soft-tissues. This information is prerequisite to the registration of multi-modal patient-specific data for enhancing the surgeon’s navigation capabilities by observing beyond exposed tissue surfaces and for providing intelligent control of robotic-assisted instruments. In minimally invasive surgery (MIS), optical techniques are an increasingly attractive approach for in vivo 3D reconstruction of the soft-tissue surface geometry. This thesis addresses the ambitious goal of achieving surgical autonomy, through the study of the anatomical environment by Initially studying the technology present and what is needed to analyze the scene: vision sensors. A novel endoscope for autonomous surgical task execution is presented in the first part of this thesis. Which combines a standard stereo camera with a depth sensor. This solution introduces several key advantages, such as the possibility of reconstructing the 3D at a greater distance than traditional endoscopes. Then the problem of hand-eye calibration is tackled, which unites the vision system and the robot in a single reference system. Increasing the accuracy in the surgical work plan. In the second part of the thesis the problem of the 3D reconstruction and the algorithms currently in use were addressed. In MIS, simultaneous localization and mapping (SLAM) can be used to localize the pose of the endoscopic camera and build ta 3D model of the tissue surface. Another key element for MIS is to have real-time knowledge of the pose of surgical tools with respect to the surgical camera and underlying anatomy. Starting from the ORB-SLAM algorithm we have modified the architecture to make it usable in an anatomical environment by adding the registration of the pre-operative information of the intervention to the map obtained from the SLAM. Once it has been proven that the slam algorithm is usable in an anatomical environment, it has been improved by adding semantic segmentation to be able to distinguish dynamic features from static ones. All the results in this thesis are validated on training setups, which mimics some of the challenges of real surgery and on setups that simulate the human body within Autonomous Robotic Surgery (ARS) and Smart Autonomous Robotic Assistant Surgeon (SARAS) projects

    Microscope Embedded Neurosurgical Training and Intraoperative System

    Get PDF
    In the recent years, neurosurgery has been strongly influenced by new technologies. Computer Aided Surgery (CAS) offers several benefits for patients\u27 safety but fine techniques targeted to obtain minimally invasive and traumatic treatments are required, since intra-operative false movements can be devastating, resulting in patients deaths. The precision of the surgical gesture is related both to accuracy of the available technological instruments and surgeon\u27s experience. In this frame, medical training is particularly important. From a technological point of view, the use of Virtual Reality (VR) for surgeon training and Augmented Reality (AR) for intra-operative treatments offer the best results. In addition, traditional techniques for training in surgery include the use of animals, phantoms and cadavers. The main limitation of these approaches is that live tissue has different properties from dead tissue and that animal anatomy is significantly different from the human. From the medical point of view, Low-Grade Gliomas (LGGs) are intrinsic brain tumours that typically occur in younger adults. The objective of related treatment is to remove as much of the tumour as possible while minimizing damage to the healthy brain. Pathological tissue may closely resemble normal brain parenchyma when looked at through the neurosurgical microscope. The tactile appreciation of the different consistency of the tumour compared to normal brain requires considerable experience on the part of the neurosurgeon and it is a vital point. The first part of this PhD thesis presents a system for realistic simulation (visual and haptic) of the spatula palpation of the LGG. This is the first prototype of a training system using VR, haptics and a real microscope for neurosurgery. This architecture can be also adapted for intra-operative purposes. In this instance, a surgeon needs the basic setup for the Image Guided Therapy (IGT) interventions: microscope, monitors and navigated surgical instruments. The same virtual environment can be AR rendered onto the microscope optics. The objective is to enhance the surgeon\u27s ability for a better intra-operative orientation by giving him a three-dimensional view and other information necessary for a safe navigation inside the patient. The last considerations have served as motivation for the second part of this work which has been devoted to improving a prototype of an AR stereoscopic microscope for neurosurgical interventions, developed in our institute in a previous work. A completely new software has been developed in order to reuse the microscope hardware, enhancing both rendering performances and usability. Since both AR and VR share the same platform, the system can be referred to as Mixed Reality System for neurosurgery. All the components are open source or at least based on a GPL license

    Enhancement of spatial awareness in natural orifice transluminal endoscopic surgery

    No full text
    Natural orifice transluminal endoscopic surgery (NOTES) represents a challenging concept to pursue in minimally invasive procedures, with a promise of becoming even less invasive, but with the additional issues of being team dependent and more technology intensive. The safety of patients undergoing any surgical procedure is of principal importance. When a surgeon performs laparoscopic procedures, he only has a two dimensional field of view and as a result, his spatial awareness is diminished. A surgeon operating under conditions of reduced spatial awareness poses an increased risk to a patient. Spatial awareness is deemed a necessary skill for the safe deployment of NOTES procedures. Understanding the surgeon’s situational and spatial awareness during NOTES investigation is therefore of paramount importance for the safe performance of this type of procedures. Enhancing scene visualisation, for instance by means of additional viewpoints or electromagnetic tracking, seems a feasible strategy for augmenting spatial awareness in NOTES. This study aims to propose novel approaches involving electromagnetic tracking and additional off-axis visualisation in an attempt to assess, as well as enhance spatial awareness of the operating field in NOTES. The original contributions of this thesis include: • Validation of an outlining approach to characterise spatial awareness in minimally invasive surgery particularly in NOTES • Qualitative and quantitative assessment of spatial awareness n NOTES • Identification of certain navigation behavioural patterns in NOTES • Design and evaluation of spatial awareness enhancement tool for NOTES The value of the research presented in this thesis, as well as the potential for further development is also discussed in the context of spatial awareness in MIS in general
    • …
    corecore