A Review on Energy Consumption Optimization Techniques in IoT Based Smart Building Environments
In recent years, due to the unnecessary wastage of electrical energy in
residential buildings, the requirement of energy optimization and user comfort
has gained vital importance. In the literature, various techniques have been
proposed addressing the energy optimization problem. The goal of each technique
was to maintain a balance between user comfort and energy requirements such
that the user can achieve the desired comfort level with the minimum amount of
energy consumption. Researchers have addressed the issue with the help of
different optimization algorithms and variations in the parameters to reduce
energy consumption. To the best of our knowledge, this problem is not solved
yet due to its challenging nature. The gap in the literature is due to the
advancements in the technology and drawbacks of the optimization algorithms and
the introduction of different new optimization algorithms. Further, many newly
proposed optimization algorithms which have produced better accuracy on the
benchmark instances but have not been applied yet for the optimization of
energy consumption in smart homes. In this paper, we have carried out a
detailed literature review of the techniques used for the optimization of
energy consumption and scheduling in smart homes. The detailed discussion has
been carried out on different factors contributing towards thermal comfort,
visual comfort, and air quality comfort. We have also reviewed the fog and edge
computing techniques used in smart homes
Hybrid Ventilation System and Soft-Sensors for Maintaining Indoor Air Quality and Thermal Comfort in Buildings
Maintaining both indoor air quality (IAQ) and thermal comfort in buildings along with optimized energy consumption is a challenging problem. This investigation presents a novel design for hybrid ventilation system enabled by predictive control and soft-sensors to achieve both IAQ and thermal comfort by combining predictive control with demand controlled ventilation (DCV). First, we show that the problem of maintaining IAQ, thermal comfort and optimal energy is a multi-objective optimization problem with competing objectives, and a predictive control approach is required to smartly control the system. This leads to many implementation challenges which are addressed by designing a hybrid ventilation scheme supported by predictive control and soft-sensors. The main idea of the hybrid ventilation system is to achieve thermal comfort by varying the ON/OFF times of the air conditioners to maintain the temperature within user-defined bands using a predictive control and IAQ is maintained using Healthbox 3.0, a DCV device. Furthermore, this study also designs soft-sensors by combining the Internet of Things (IoT)-based sensors with deep-learning tools. The hardware realization of the control and IoT prototype is also discussed. The proposed novel hybrid ventilation system and the soft-sensors are demonstrated in a real research laboratory, i.e., Center for Research in Automatic Control Engineering (C-RACE) located at Kalasalingam University, India. Our results show the perceived benefits of hybrid ventilation, predictive control, and soft-sensors
Recommended from our members
Cooling load forecasting-based predictive optimisation for chiller plants
Extensive electric power is required to maintain indoor thermal comfort using heating, ventilation and air conditioning (HVAC) systems, of which, water-cooled chiller plants consume more than 50% of the total electric power. To improve energy efficiency, supervisory optimisation control can be adopted. The controlled variables are usually optimised according to instant building cooling load and ambient wet bulb air temperature at regular time intervals. In this way, the energy efficiency of chiller plants has been improved. However, with an inherent assumption that the instant building cooling load and ambient wet bulb temperature remain constant in the coming time interval, the energy efficiency potential has not been fully realised, especially when cooling loads vary suddenly and extremely. To solve this problem, a cooling load forecasting-based predictive optimisation method is proposed. Instead of minimising the instant system power according to the instant building cooling load and ambient wet bulb temperature, the controlled variables are derived to minimise the sum of the instant system power and one-time-step-ahead future system power according to both instant and forecasted future building cooling loads. With this method, the energy efficiency potential of a chiller plant can be further improved without shortening the operation time interval. 80% redundant energy consumption has been reduced for the sample chiller plant; energy can be saved for chiller plants that work for years. The evaluation on the effect of cooling load forecasting accuracy turns out that the more accurate the forecasts are, the more redundant energy consumption can be reduced
Analysis of the economic feasibility and reduction of a building’s energy consumption and emissions when integrating hybrid solar thermal/PV/micro-CHP systems
The aim of this paper is to assess the performance of several designs of hybrid systems composed of solar thermal collectors, photovoltaic panels and natural gas internal combustion engines. The software TRNSYS 17 has been used to perform all the calculations and data processing, as well as an optimisation of the tank volumes through an add-in coupled with the GENOPT® software. The study is carried out by analysing the behaviour of the designed systems and the conventional case in five different locations of Spain with diverse climatic characteristics, evaluating the same building in all cases. Regulators, manufacturers and energy service engineers are the most interested in these results.
Two major contributions in this paper are the calculations of primary energy consumption and emissions and the inclusion of a Life Cycle Cost analysis. A table which shows the order of preference regarding those criteria for each considered case study is also included. This was fulfilled in the interest of comparing between the different configurations and climatic zones so as to obtain conclusions on each of them. The study also illustrates a sensibility analysis regarding energy prices. Finally, the exhaustive literature review, the novel electricity consumption profile of the building and the illustration of the influence of the cogeneration engine working hours are also valuable outputs of this paper, developed in order to address the knowledge gap and the ongoing challenges in the field of distributed generation
Demand response within the energy-for-water-nexus - A review. ESRI WP637, October 2019
A promising tool to achieve more flexibility within power systems is demand re-sponse (DR). End-users in many strands
of industry have been subject to research up to now regarding the opportunities for implementing DR programmes. One sector
that has received little attention from the literature so far, is wastewater treatment. However, case studies indicate that the
potential for wastewater treatment plants to provide DR services might be significant. This review presents and categorises recent
modelling approaches for industrial demand response as well as for the wastewater treatment plant operation. Furthermore, the
main sources of flexibility from wastewater treatment plants are presented: a potential for variable electricity use in aeration, the
time-shifting operation of pumps, the exploitation of built-in redundan-cy in the system and flexibility in the sludge processing.
Although case studies con-note the potential for DR from individual WWTPs, no study acknowledges the en-dogeneity of energy
prices which arises from a large-scale utilisation of DR. There-fore, an integrated energy systems approach is required to quantify
system and market effects effectively
- …