1,208 research outputs found

    Control of multi-terminal HVDC networks towards wind power integration: A review

    Get PDF
    © 2015 Elsevier Ltd. More interconnections among countries and synchronous areas are foreseen in order to fulfil the EU 2050 target on the renewable generation share. One proposal to accomplish this challenging objective is the development of the so-called European SuperGrid. Multi-terminal HVDC networks are emerging as the most promising technologies to develop such a concept. Moreover, multi-terminal HVDC grids are based on highly controllable devices, which may allow not only transmitting power, but also supporting the AC grids to ensure a secure and stable operation. This paper aims to present an overview of different control schemes for multi-terminal HVDC grids, including the control of the power converters and the controls for power sharing and the provision of ancillary services. This paper also analyses the proposed modifications of the existing control schemes to manage high participation shares of wind power generation in multi-terminal grids.Postprint (author's final draft

    Topology assessment for 3 + 3 terminal offshore DC grid considering DC fault management

    Get PDF
    Peer reviewedPostprin

    Fault analysis and protection for wind power generation systems

    Get PDF
    Wind power is growing rapidly around the world as a means of dealing with the world energy shortage and associated environmental problems. Ambitious plans concerning renewable energy applications around European countries require a reliable yet economic system to generate, collect and transmit electrical power from renewable resources. In populous Europe, collective offshore large-scale wind farms are efficient and have the potential to reach this sustainable goal. This means that an even more reliable collection and transmission system is sought. However, this relatively new area of offshore wind power generation lacks systematic fault transient analysis and operational experience to enhance further development. At the same time, appropriate fault protection schemes are required. This thesis focuses on the analysis of fault conditions and investigates effective fault ride-through and protection schemes in the electrical systems of wind farms, for both small-scale land and large-scale offshore systems. Two variable-speed generation systems are considered: doubly-fed induction generators (DFIGs) and permanent magnet synchronous generators (PMSGs) because of their popularity nowadays for wind turbines scaling to several-MW systems. The main content of the thesis is as follows. The protection issues of DFIGs are discussed, with a novel protection scheme proposed. Then the analysis of protection scheme options for the fully rated converter, direct-driven PMSGs are examined and performed with simulation comparisons. Further, the protection schemes for wind farm collection and transmission systems are studied in terms of voltage level, collection level wind farm collection grids and high-voltage transmission systems for multi-terminal DC connected transmission systems, the so-called “Supergrid”. Throughout the thesis, theoretical analyses of fault transient performances are detailed with PSCAD/EMTDC simulation results for verification. Finally, the economic aspect for possible redundant design of wind farm electrical systems is investigated based on operational and economic statistics from an example wind farm project

    A review on DC collection grids for offshore wind farms with HVDC transmission system

    Get PDF
    Abstract: Traditionally, the internal network composition of offshore wind farms consists of alternating current (AC) collection grid; all outputs of wind energy conversion units (WECUs) on a wind farm are aggregated to an AC bus. Each WECU includes: a wind-turbine plus mechanical parts, a generator including electronic controller, and a huge 50-or 60-Hz power transformer. For a DC collection grid, all outputs of WECUs are aggregated to a DC bus; consequently, the transformer in each WECU is replaced by a power converter or rectifier. The converter is more compact and smaller in size compared to the transformer. Thus reducing the size and weight of the WECUs, and also simplifying the wind farm structure. Actually, the use of offshore AC collection grids instead of offshore DC collection grids is mainly motivated by the availability of control and protection devices. However, efficient solutions to control and protect DC grids including HVDC transmission systems have already been addressed. Presently, there are no operational wind farms with DC collection grids, only theoretical and small-scale prototypes are being investigated worldwide. Therefore, a suitable configuration of the DC collection grid, which has been practically verified, is not available yet. This paper discussed some of the main components required for a DC collection grid including: the wind-turbine-generator models, the control and protection methods, the offshore platform structure, and the DC-grid feeder configurations. The key component of a DC collection grid is the power converter; therefore, the paper also reviews some topologies of power converter suitable for DC grid applications

    Neuro-Fuzzy Based High-Voltage DC Model to Optimize Frequency Stability of an Offshore Wind Farm

    Get PDF
    Lack of synchronization between high voltage DC systems linking offshore wind farms and the onshore grid is a natural consequence owing to the stochastic nature of wind energy. The poor synchronization results in increased system disturbances, grid contingencies, power loss, and frequency instability. Emphasizing frequency stability analysis, this research investigates a dynamic coordination control technique for a Double Fed Induction Generator (DFIG) consisting of OWFs integrated with a hybrid multi-terminal HVDC (MTDC) system. Line commutated converters (LCC) and voltage source converters (VSC) are used in the suggested control method in order to ensure frequency stability. The adaptive neuro-fuzzy inference approach is used to accurately predict wind speed in order to further improve frequency stability. The proposed HVDC system can integrate multiple distributed OWFs with the onshore grid system, and the control strategy is designed based on this concept. In order to ensure the transient stability of the HVDC system, the DFIG-based OWF is regulated by a rotor side controller (RSC) and a grid side controller (GSC) at the grid side using a STATCOM. The devised HVDC (MTDC) is simulated in MATLAB/SIMULINK, and the performance is evaluated in terms of different parameters, such as frequency, wind power, rotor and stator side current, torque, speed, and power. Experimental results are compared to a conventional optimal power flow (OPF) model to validate the performance.© 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).fi=vertaisarvioitu|en=peerReviewed

    Multiterminal HVDC transmissions systems for offshore wind

    Get PDF
    Offshore wind is emerging as one of the future energy vectors. Offshore wind power plants locations provide more strong and constant wind speed that allows to extract more power compared to onshore locations. In addition, as wind turbine components transportation is less restricted to terrestrial infrastructure, bigger and more powerful wind turbines can be installed offshore. In Europe, 1,567 MW of offshore wind power was installed in 2013. It represents the 14\% of the total wind power installed in Europe. Offshore wind power plants near the shore can be connected to the main grid by means of conventional AC technology. However, if these wind farms are installed further than 80-100 km, the use of AC equipment is economically infeasible due to reactive power issues. In these applications, HVDC system based on static converters can be used. The projects build and commissioned nowadays are based on point-to-point connections, where, each wind farm or wind farm clusters are connected to the terrestrial grid individually. Consequently, these lines might be understood as an extension of the AC system. If different offshore wind farms are interconnected between them and connected at the same time to different AC systems, for example, different countries, the DC grid is created. This scenario creates one of the most important challenges in the electrical power system since its creation, more than 100 years ago. The most relevant challenges to be addressed are the stability and operation of the DC grid and the integration and interaction with the AC grid. This thesis addresses various aspects related to the future Multiterminal-HVDC systems for transmission of offshore wind power. First, the voltage control and the system operations are discussed and verified by means of emulations using an HVDC scaled experimental platform built for this purpose. Voltage stability might be endangered during contingencies due to the different inertia time constant of the AC and the DC system. DC systems only have the inertia of the capacitors compared to synchronous machines rotating masses of the AC systems. Therefore, in faulty conditions the power transmitted through the DC system must be reduced quickly and efficiently. For this reason, in this thesis a coordinated power reduction algorithm taking advantage of Dynamic Braking Resistors (DBR) connected to onshore converter stations and the ability of the power plants to reduce the generated power is presented. From the AC and DC grids integration point of view, the connection point between the offshore grid and the AC grid might be located remotely leading to a connection with a reduced Short Circuit Ratio (SCR). In the literature, several issues regarding the connection of transistor-based power converters to weak AC grid have been reported. In this thesis am advanced control for Voltage Source Converters connected to weak grids is presented and tested by means of simulations. From the AC and DC grids interactions, the voltage stability is not enough to operate a DC grid. Transport System Operators (TSO) operates the power flow through the cables and the power exchanged between by the power converters. In this thesis, a novel hierarchical power flow control method is presented. The aim of the proposed power flow control is to obtain the desired power flows changing the voltage control set-points while the system stability is ensured. Finally, a control procedure for offshore wind farms based on Squirrel Cage Induction Generators connected to a single power converter is introduced.L'energia eòlica marina emergeix com un dels vectors energètics del futur. Les localitzacions eòliques marines proporcionen vens més forts i constants que les terrestres, cosa que permet extreure més potència. A més a més, els aerogeneradors marins poden ser més grans i més potents ja que es redueixen les limitacions de gàlib existent en les infraestructures terrestres. A tall d'exemple, l'any 2013 a Europa es van instal.lar 1.567 MW de potència eòlica marina, cosa que representa un 14\% de la potència eòlica instal.lada a Europa. Els parcs eòlics marins poden ser connectats a la xarxa elèctrica terrestre utilitzant emparamenta convencional de corrent alterna, però quan la distancia amb la costa excedeix els 80-100 km l'ús d'aquesta tecnologia es torna econòmicament inviable degut a l'energia reactiva generada en els conductors. Per solucionar aquest problema, s'emparen els sistemes en corrent continua basats en convertidors estàtics. Els projectes construïts o projectats a dia d'avui es basen en esquemes de connexió punt-a-punt, on, cada parc eòlic o agrupació de parcs eòlics es troba connectat a la xara terrestre individualment. En conseqüència, l'operació d'aquestes línies es pot considerar com una extensió de la xarxa d'alterna. Però, si s'interconnecten diferents parc eòlics amb diferents xarxes terrestres d'alterna (per exemple, diferents països) en corrent continua, s'obtenen xarxes en corrent continua. Aquest nou escenari crea un dels majors reptes des de la creació dels sistema elèctric de potencia, ara fa més de 100 anys. Entre aquests reptes hi ha l'estabilitat i l'operació dels sistemes en corrent contínua i la seva integració i coexistència amb les xarxes en corrent alterna. En la present tesis s'han estudiat diferents aspectes dels futurs sistemes multi terminal en alta tensió en corrent contínua (HVDC, en anglès) per la transmissió de potencia generada mitjançant parcs eòlics marins. Primerament, es descriu el control de tensió i els modes d'operació dels sistemes multi terminal i es verifiquen en una plataforma experimental construïda per aquest propòsit. L'estabilitat de tensió dels sistemes en corrent continua, es pot veure afectada durant una falta a la xarxa d'alterna degut a la reduïda inèrcia dels sistemes multi terminal, només formada pels condensadors dels convertidors i els cables. Així la potència que no pot injectar a la xarxa ha de ser reduïda de forma ràpida i eficient. Per això, en aquesta tesis es presenta un sistema coordinat de reducció de potència que utilitza la resistència de frenat dels convertidors de connexió a la xarxa i els mètodes de reducció de potència dels parcs eòlics. Des del punt de vista de la integració de les xarxes en continua i en alterna, el punt d'interconnexió pot estar localitzat llunys dels grans centres de generació, la qual cosa implica tenir una potència de curtcircuit molt reduïda. En la bibliografia científica s'han descrit diverses problemàtiques a l'hora de connectar un convertidor de commutació forçada a les xarxes dèbils. Per tal de pal.liar aquests inconvenients, en aquesta tesis es presenta un algorisme avançat de connexió de convertidors a xarxes dèbils basat en control vectorial. Des del punt de vista de les interaccions i interoperabilitat dels sistemes en corrent alterna i continua, no n'hi ha suficient en garantir l'estabilitat, ja que el propòsit finals dels operadors de xarxa és fer fluir una potencia a traves de la xarxa per tal de satisfer la demanda. Per aquest propòsit en aquesta tesis es presenta un control jeràrquic de control del flux de potència que fixa el flux de potència a traves d'una xarxa multi terminal canviant les consignes del control primari, tot assegurant l'estabilitat del sistema. Per tancar la tesis, es presenta un nou controlador per parcs eòlics basats en aerogeneradors de gàbia d'esquirol controlats per un sol convertidor

    DC Grids : Motivation, Feasibility and Outstanding Issues : Status Report for the European Commission Deliverable : D5.4

    Get PDF
    Wind energy is already a mainstay of clean power generation in Europe, with over 100GW of capacity installed so far, and another 120GW anticipated by 2020 according to various analysts. Much of this capacity is expected to be installed offshore, as it is a windier and the source is steadier compared to onshore wind energy. Hence, offshore wind has been envisaged as making a critical contribution to Europe’s demand for electrical energy and to minimising the carbon emissions associated with meeting that demand

    Offshore Wind Farm-Grid Integration: A Review on Infrastructure, Challenges, and Grid Solutions

    Get PDF
    Recently, the penetration of renewable energy sources (RESs) into electrical power systems is witnessing a large attention due to their inexhaustibility, environmental benefits, storage capabilities, lower maintenance and stronger economy, etc. Among these RESs, offshore wind power plants (OWPP) are ones of the most widespread power plants that have emerged with regard to being competitive with other energy technologies. However, the application of power electronic converters (PECs), offshore transmission lines and large substation transformers result in considerable power quality (PQ) issues in grid connected OWPP. Moreover, due to the installation of filters for each OWPP, some other challenges such as voltage and frequency stability arise. In this regard, various customs power devices along with integration control methodologies have been implemented to deal with stated issues. Furthermore, for a smooth and reliable operation of the system, each country established various grid codes. Although various mitigation schemes and related standards for OWPP are documented separately, a comprehensive review covering these aspects has not yet addressed in the literature. The objective of this study is to compare and relate prior as well as latest developments on PQ and stability challenges and their solutions. Low voltage ride through (LVRT) schemes and associated grid codes prevalent for the interconnection of OWPP based power grid have been deliberated. In addition, various PQ issues and mitigation options such as FACTS based filters, DFIG based adaptive and conventional control algorithms, ESS based methods and LVRT requirements have been summarized and compared. Finally, recommendations and future trends for PQ improvement are highlighted at the end

    Design and Control of A DC Grid for Offshore Wind Farms

    Get PDF

    Load Flow Analysis of Hybrid AC-DC Power System with Offshore Wind Power

    Get PDF
    corecore