8,695 research outputs found

    Consensus-based Distributed Control for Accurate Reactive, Harmonic and Imbalance Power Sharing in Microgrids

    Get PDF

    Distributed Control Strategies for Microgrids: An Overview

    Get PDF
    There is an increasing interest and research effort focused on the analysis, design and implementation of distributed control systems for AC, DC and hybrid AC/DC microgrids. It is claimed that distributed controllers have several advantages over centralised control schemes, e.g., improved reliability, flexibility, controllability, black start operation, robustness to failure in the communication links, etc. In this work, an overview of the state-of-the-art of distributed cooperative control systems for isolated microgrids is presented. Protocols for cooperative control such as linear consensus, heterogeneous consensus and finite-time consensus are discussed and reviewed in this paper. Distributed cooperative algorithms for primary and secondary control systems, including (among others issues) virtual impedance, synthetic inertia, droop-free control, stability analysis, imbalance sharing, total harmonic distortion regulation, are also reviewed and discussed in this survey. Tertiary control systems, e.g., for economic dispatch of electric energy, based on cooperative control approaches, are also addressed in this work. This review also highlights existing issues, research challenges and future trends in distributed cooperative control of microgrids and their future applications

    Hybrid Maritime Microgrids: A Quest for Future Onboard Integrated Marine Power Systems

    Get PDF
    The following is a comprehensive analysis which details potential ways for the maritime industry to begin to phase out AC power generation and distribution on new vessels over a short period of time. Therefore, the vessels of the future should consider transitioning into DC power generation and distribution. During the transition from AC shipboard systems to DC shipboard systems, there will be a time during which the vessels will be run by “hybrid” shipboard power systems, which utilize a mixture of AC and DC power. These systems are known as integrated marine power systems (IMPS) or hybrid maritime microgrid architectures, since they represent a distribution system or a part thereof. This study presents a state of the art of maritime systems, emphasizing on the design aspects of hybrid maritime microgrids, summarizing the advantages, disadvantages, and the challenges that planners may face when it comes to the vessels of the future. This study also reviews remedies that have been recently proposed in the literature to overcome such challenges. In addition, this work reports on the problem of service restoration of shipboard power systems and introduces directions on how to enhance the survivability of maritime power systems using techniques based on distribution system reconfiguration

    Review of Active and Reactive Power Sharing Strategies in Hierarchical Controlled Microgrids

    Get PDF

    Review of Power Sharing Control Strategies for Islanding Operation of AC Microgrids

    Get PDF

    A Study on the Hierarchical Control Structure of the Islanded Microgrid

    Get PDF
    The microgrid is essential in promoting the power system’s resilience through its ability to host small-scale DG units. Furthermore, the microgrid can isolate itself during main grid faults and supply its demands. However, islanded operation of the microgrid is challenging due to difficulties in frequency and voltage control. In islanded mode, grid-forming units collaborate to control the frequency and voltage. A hierarchical control structure employing the droop control technique provides these control objectives in three consecutive levels: primary, secondary, and tertiary. However, challenges associated with DG units in the vicinity of distribution networks limit the effectiveness of the islanded mode of operation.In MV and LV distribution networks, the X/R ratio is low; hence, the frequency and voltage are related to the active and reactive power by line parameters. Therefore, frequency and voltage must be tuned for changes in active or reactive powers. Furthermore, the line parameters mismatch causes the voltage to be measured differently at each bus due to the different voltage drops in the lines. Hence, a trade-off between voltage regulation and reactive power-sharing is formed, which causes either circulating currents for voltage mismatch or overloading for reactive power mismatch. Finally, the economic dispatch is usually implemented in tertiary control, which takes minutes to hours. Therefore, an estimation algorithm is required for load and renewable energy quantities forecasting. Hence, prediction errors may occur that affect the stability and optimality of the control. This dissertation aims to improve the power system resilience by enhancing the operation of the islanded microgrid by addressing the above-mentioned issues. Firstly, a linear relationship described by line parameters is used in droop control at the primary control level to accurately control the frequency and voltage based on measured active and reactive power. Secondly, an optimization-based consensus secondary control is presented to manage the trade-off between voltage regulation and reactive power-sharing in the inductive grid with high line parameters mismatch. Thirdly, the economic dispatch-based secondary controller is implemented in secondary control to avoid prediction errors by depending on the measured active and reactive powers rather than the load and renewable energy generation estimation. The developed methods effectively resolve the frequency and voltage control issues in MATLAB/SIMULINK simulations

    Active power sharing and frequency regulation in inverter-based islanded microgrids subject to clock drifts, damage in power links and loss of communications

    Get PDF
    Tesi en modalitat de compendi de publicacions; hi ha diferents seccions retallades per drets de l'editorMicrogrids (MGs) are small-scale power systems containing storage elements, loads and distributed generators that are interfaced with the electric network via power electronic inverters. When an MG is in islanded mode, its dynamics are no longer dominated by the main grid. Then, inverters, driven by digital processors that may exchange data over digital communication, must act as voltage source inverters (VSIs) to take coordinated actions to ensure power quality and supply. The scope of this thesis is bounded to control strategies for active power sharing and frequency regulation in islanded MGs. The focus is on the analysis of prototype control policies when operating conditions are no longer ideal. In particular, the thesis covers the effect that a) clock drifts of digital processors, b) damage in power transmission lines, and c) failures in digital communications have in control performance. The work is submitted as a compendium of publications, including journal and international conference papers, where two main areas of research can be distinguished. The first area refers to the analysis of the effect that clock drifts have on frequency regulation and active power sharing. VSIs digital processors are equipped with oscillators, which run at not necessarily identical frequencies. As consequence, the local clocks in the physically distributed VSIs may differ. This part, reported in two conference papers and one journal paper, investigates state-of-the-art control policies when clocks of the computational devices drift. The contributions related to this part are a) the reformulation of existing control policies in terms of clock drifts, b) the steady-state analysis of these policies that offers analytical expressions to quantify the impact that drifts have on frequency and active power equilibrium points, c) the closed-loop model capable of accommodating all the policies, d) the stability analysis of the equilibrium points, and e) the experimental results. The second area copes with the analysis of the effect that electrical and communication failures have on frequency regulation and active power sharing. This investigation focuses on distributed/cooperative control policies where each inverter control action is computed using both local measures and data received from other inverters within the MG. This part, reported in one conference paper and two journal papers, investigates two control policies when the considered failures in terms of damage in power links and/or loss of communication between inverters provoke partitions within the MG. The contributions related to this part are a) the formulation of the MG as two connected graphs corresponding to the electrical and communication networks where both type of failures lead to disconnected electrical/communication sub-graphs, named partitions, that co-exist within the MG, b) the closed-loop model integrating the two graph Laplacian matrices, c) the stability analysis that identifies which type of partitions may lead to MG instability, d) the steady-state analysis that indicates how to compute the equilibrium points for the case of stable dynamics, e) a new control strategy based on switched control principles that permits avoiding the instability scenario, and f) the experimental results. For the purpose of verifying the operational performance of the analytical results, diverse experiments on a laboratory MG have been performed. The outcomes obtained are discussed and analyzed in terms of the objectives sought. Finally, conclusions and future research lines complete the thesis.Las microredes (MG) son sistemas de energía a pequeña escala que contienen elementos de almacenamiento, cargas y generadores distribuidos que están conectados con la red eléctrica a través de inversores de potencia. Cuando una MG está en modo aislado, su dinámica no está dominada por la red principal. Así, los inversores, comandados por procesadores digitales que pueden intercambiar información a través de comunicaciones digitales, deben actuar como fuentes de voltaje para ejecutar acciones coordinadas que garanticen el suministro de energía. Esta tesis se enmarca dentro de estrategias de control de última generación para compartir potencia activa y regular frecuencia en MG aisladas basadas en inversores. Su enfoque se centra en analizar estas políticas cuando las condiciones de operación no son ideales. En particular, la tesis cubre el efecto que a) desviaciones del reloj de los procesadores digitales, b) daños en las líneas de transmisión de energía, y c) fallas en las comunicaciones digitales, provocan en el rendimiento de control. El trabajo se presenta como un compendio que incluye publicaciones de revistas y de conferencias internacionales, donde se pueden distinguir dos temas principales de investigación. El primer tema comprende el análisis del efecto que tienen las desviaciones de reloj sobre la regulación de frecuencia y la compartición de potencia activa. Los procesadores de los inversores están equipados con osciladores que funcionan a frecuencias no necesariamente idénticas. Como consecuencia, los relojes locales en los inversores distribuidos físicamente, pueden diferir. Esta parte, descrita a través de dos artículos de conferencia y uno de revista, analiza el comportamiento de las políticas de control cuando los relojes de los dispositivos computacionales se desvían. Las contribuciones relacionadas con este tema son a) reformulación de las políticas de control de última generación en términos de desviaciones de reloj, b) análisis de estado estacionario de estas estrategias que ofrece expresiones analíticas para cuantificar el impacto que las desviaciones de reloj tienen sobre los puntos de equilibrio de frecuencia y potencia activa, c) modelo de lazo cerrado adaptable a todas las políticas, d) análisis de estabilidad de los puntos de equilibrio, y e) resultados experimentales. El segundo tema hace frente al análisis del efecto que las fallas eléctricas y de comunicaciones tienen sobre la regulación de frecuencia y el uso compartido de potencia activa. Esta parte se centra en políticas de control distribuido/cooperativo donde cada acción de control del inversor se calcula utilizando medidas locales y datos recibidos de otros inversores de la MG. Esta parte, descrita a través de un artículo de conferencia y dos de revista, investiga dos políticas de control cuando particiones en la MG son provocadas por daños en los enlaces de alimentación y/o por pérdida de comunicación entre inversores. Las contribuciones relacionadas con este tema son a) formulación de la MG como dos grafos correspondientes a las redes eléctrica y de comunicación donde ambos tipos de fallas conducen a sub-grafos eléctricos/comunicacionales desconectados, llamados particiones, que coexisten dentro de la MG, b) modelo de lazo cerrado que integra las matrices Laplacianas de los dos grafos, c) análisis de estabilidad que identifica las particiones que pueden conducir a inestabilidad en la MG, d) análisis de estado estacionario para calcular puntos de equilibrio cuando la dinámica es estable, e) nueva estrategia basada en principios de control conmutado para evitar el escenario de inestabilidad, y f) resultados experimentales. Con el fin de verificar el rendimiento operativo de los resultados analíticos, se han realizado diversos experimentos sobre una microred de laboratorio, los mismos que se discuten en términos de los objetivos de la tesis. El trabajo finaliza con las conclusionesPostprint (published version

    Design of Space Microgrid for Manned Lunar Base:Spinning-in Terrestrial Technologies

    Get PDF
    corecore