Evaluation of PPG Biometrics for Authentication in different states
Amongst all medical biometric traits, Photoplethysmograph (PPG) is the
easiest to acquire. PPG records the blood volume change with just combination
of Light Emitting Diode and Photodiode from any part of the body. With IoT and
smart homes' penetration, PPG recording can easily be integrated with other
vital wearable devices. PPG represents peculiarity of hemodynamics and
cardiovascular system for each individual. This paper presents non-fiducial
method for PPG based biometric authentication. Being a physiological signal,
PPG signal alters with physical/mental stress and time. For robustness, these
variations cannot be ignored. While, most of the previous works focused only on
single session, this paper demonstrates extensive performance evaluation of PPG
biometrics against single session data, different emotions, physical exercise
and time-lapse using Continuous Wavelet Transform (CWT) and Direct Linear
Discriminant Analysis (DLDA). When evaluated on different states and datasets,
equal error rate (EER) of - was achieved for -s average
training time. Our CWT/DLDA based technique outperformed all other
dimensionality reduction techniques and previous work.Comment: Accepted at 11th IAPR/IEEE International Conference on Biometrics,
2018. 6 pages, 6 figure
CardioCam: Leveraging Camera on Mobile Devices to Verify Users While Their Heart is Pumping
With the increasing prevalence of mobile and IoT devices (e.g., smartphones, tablets, smart-home appliances), massive private and sensitive information are stored on these devices. To prevent unauthorized access on these devices, existing user verification solutions either rely on the complexity of user-defined secrets (e.g., password) or resort to specialized biometric sensors (e.g., fingerprint reader), but the users may still suffer from various attacks, such as password theft, shoulder surfing, smudge, and forged biometrics attacks. In this paper, we propose, CardioCam, a low-cost, general, hard-to-forge user verification system leveraging the unique cardiac biometrics extracted from the readily available built-in cameras in mobile and IoT devices. We demonstrate that the unique cardiac features can be extracted from the cardiac motion patterns in fingertips, by pressing on the built-in camera. To mitigate the impacts of various ambient lighting conditions and human movements under practical scenarios, CardioCam develops a gradient-based technique to optimize the camera configuration, and dynamically selects the most sensitive pixels in a camera frame to extract reliable cardiac motion patterns. Furthermore, the morphological characteristic analysis is deployed to derive user-specific cardiac features, and a feature transformation scheme grounded on Principle Component Analysis (PCA) is developed to enhance the robustness of cardiac biometrics for effective user verification. With the prototyped system, extensive experiments involving 25 subjects are conducted to demonstrate that CardioCam can achieve effective and reliable user verification with over 99% average true positive rate (TPR) while maintaining the false positive rate (FPR) as low as 4%
Seeing Red: PPG Biometrics Using Smartphone Cameras
In this paper, we propose a system that enables photoplethysmogram
(PPG)-based authentication by using a smartphone camera. PPG signals are
obtained by recording a video from the camera as users are resting their finger
on top of the camera lens. The signals can be extracted based on subtle changes
in the video that are due to changes in the light reflection properties of the
skin as the blood flows through the finger. We collect a dataset of PPG
measurements from a set of 15 users over the course of 6-11 sessions per user
using an iPhone X for the measurements. We design an authentication pipeline
that leverages the uniqueness of each individual's cardiovascular system,
identifying a set of distinctive features from each heartbeat. We conduct a set
of experiments to evaluate the recognition performance of the PPG biometric
trait, including cross-session scenarios which have been disregarded in
previous work. We found that when aggregating sufficient samples for the
decision we achieve an EER as low as 8%, but that the performance greatly
decreases in the cross-session scenario, with an average EER of 20%.Comment: 8 pages, 15th IEEE Computer Society Workshop on Biometrics 202
Biometric authentication using the PPG: A long-term feasibility study
The photoplethysmogram (PPG) is a biomedical signal that can be used to estimate volumetric blood flow changes in the peripheral circulation. During the past few years, several works have been published in order to assess the potential for PPGs to be used in biometric authentication systems, but results are inconclusive. In this paper we perform an analysis of the feasibility of using the PPG as a realistic biometric alternative in the long term. Several feature extractors (based on the time domain and the Karhunen–Loève transform) and matching metrics (Manhattan and Euclidean distances) have been tested using four different PPG databases (PRRB, MIMIC-II, Berry, and Nonin). We show that the false match rate (FMR) and false non-match rate (FNMR) values remain constant in different time instances for a selected threshold, which is essential for using the PPG for biometric authentication purposes. On the other hand, obtained equal error rate (EER) values for signals recorded during the same session range from 1.0% for high-quality signals recorded in controlled conditions to 8% for those recorded in conditions closer to real-world scenarios. Moreover, in certain scenarios, EER values rise up to 23.2% for signals recorded over different days, signaling that performance degradation could take place with time
A Survey of PPG's Application in Authentication
Biometric authentication prospered because of its convenient use and
security. Early generations of biometric mechanisms suffer from spoofing
attacks. Recently, unobservable physiological signals (e.g.,
Electroencephalogram, Photoplethysmogram, Electrocardiogram) as biometrics
offer a potential remedy to this problem. In particular, Photoplethysmogram
(PPG) measures the change in blood flow of the human body by an optical method.
Clinically, researchers commonly use PPG signals to obtain patients' blood
oxygen saturation, heart rate, and other information to assist in diagnosing
heart-related diseases. Since PPG signals contain a wealth of individual
cardiac information, researchers have begun to explore their potential in cyber
security applications. The unique advantages (simple acquisition, difficult to
steal, and live detection) of the PPG signal allow it to improve the security
and usability of the authentication in various aspects. However, the research
on PPG-based authentication is still in its infancy. The lack of
systematization hinders new research in this field. We conduct a comprehensive
study of PPG-based authentication and discuss these applications' limitations
before pointing out future research directions.Comment: Accepted by Computer & Security (COSE
Transcending conventional biometry frontiers: Diffusive Dynamics PPG Biometry
In the first half of the 20th century, a first pulse oximeter was available
to measure blood flow changes in the peripheral vascular net. However, it was
not until recent times the PhotoPlethysmoGraphic (PPG) signal used to monitor
many physiological parameters in clinical environments. Over the last decade,
its use has extended to the area of biometrics, with different methods that
allow the extraction of characteristic features of each individual from the PPG
signal morphology, highly varying with time and the physical states of the
subject. In this paper, we present a novel PPG-based biometric authentication
system based on convolutional neural networks. Contrary to previous approaches,
our method extracts the PPG signal's biometric characteristics from its
diffusive dynamics, characterized by geometric patterns image in the (p,
q)-planes specific to the 0-1 test. The diffusive dynamics of the PPG signal
are strongly dependent on the vascular bed's biostructure, which is unique to
each individual, and highly stable over time and other psychosomatic
conditions. Besides its robustness, our biometric method is anti-spoofing,
given the convoluted nature of the blood network. Our biometric authentication
system reaches very low Equal Error Rates (ERRs) with a single attempt, making
it possible, by the very nature of the envisaged solution, to implement it in
miniature components easily integrated into wearable biometric systems.Comment: 18 pages, 6 figures, 4 table
Cybersecurity in implantable medical devices
Mención Internacional en el título de doctorImplantable Medical Devices (IMDs) are electronic devices implanted within
the body to treat a medical condition, monitor the state or improve the
functioning of some body part, or just to provide the patient with a capability
that he did not possess before [86]. Current examples of IMDs
include pacemakers and defibrillators to monitor and treat cardiac conditions;
neurostimulators for deep brain stimulation in cases such as epilepsy
or Parkinson; drug delivery systems in the form of infusion pumps; and a
variety of biosensors to acquire and process different biosignals.
Some of the newest IMDs have started to incorporate numerous communication
and networking functions—usually known as “telemetry”—,
as well as increasingly more sophisticated computing capabilities. This
has provided implants with more intelligence and patients with more autonomy,
as medical personnel can access data and reconfigure the implant
remotely (i.e., without the patient being physically present in medical facilities).
Apart from a significant cost reduction, telemetry and computing
capabilities also allow healthcare providers to constantly monitor the patient’s
condition and to develop new diagnostic techniques based on an
Intra Body Network (IBN) of medical devices [25, 26, 201].
Evolving from a mere electromechanical IMD to one with more advanced
computing and communication capabilities has many benefits but
also entails numerous security and privacy risks for the patient. The majority
of such risks are relatively well known in classical computing scenarios,
though in many respects their repercussions are far more critical in the case
of implants. Attacks against an IMD can put at risk the safety of the patient
who carries it, with fatal consequences in certain cases. Causing an intentional
malfunction of an implant can lead to death and, as recognized by the
U.S. Food and Drug Administration (FDA), such deliberate attacks could
be far more difficult to detect than accidental ones [61]. Furthermore, these
devices store and transmit very sensitive medical information that requires
protection, as dictated by European (e.g., Directive 95/46/ECC) and U.S.
(e.g., CFR 164.312) Directives [94, 204].
The wireless communication capabilities present in many modern IMDs
are a major source of security risks, particularly while the patient is in open
(i.e., non-medical) environments. To begin with, the implant becomes no
longer “invisible”, as its presence could be remotely detected [48]. Furthermore,
it facilitates the access to transmitted data by eavesdroppers who
simply listen to the (insecure) channel [83]. This could result in a major privacy breach, as IMDs store sensitive information such as vital signals,
diagnosed conditions, therapies, and a variety of personal data (e.g., birth
date, name, and other medically relevant identifiers). A vulnerable communication
channel also makes it easier to attack the implant in ways similar
to those used against more common computing devices [118, 129, 156],
i.e., by forging, altering, or replying previously captured messages [82].
This could potentially allow an adversary to monitor and modify the implant
without necessarily being close to the victim [164]. In this regard,
the concerns of former U.S. vice-president Dick Cheney constitute an excellent
example: he had his Implantable Cardioverter Defibrillator (ICD)
replaced by another without WiFi capability [219].
While there are still no known real-world incidents, several attacks on
IMDs have been successfully demonstrated in the lab [83, 133, 143]. These
attacks have shown how an adversary can disable or reprogram therapies
on an ICD with wireless connectivity, and even inducing a shock state to
the patient [65]. Other attacks deplete the battery and render the device
inoperative [91], which often implies that the patient must undergo a surgical
procedure to have the IMD replaced. Moreover, in the case of cardiac
implants, they have a switch that can be turned off merely by applying a
magnetic field [149]. The existence of this mechanism is motivated by the
need to shield ICDs to electromagnetic fields, for instance when the patient
undergoes cardiac surgery using electrocautery devices [47]. However, this
could be easily exploited by an attacker, since activating such a primitive
mechanism does not require any kind of authentication.
In order to prevent attacks, it is imperative that the new generation of
IMDs will be equipped with strong mechanisms guaranteeing basic security
properties such as confidentiality, integrity, and availability. For example,
mutual authentication between the IMD and medical personnel is
essential, as both parties must be confident that the other end is who claims
to be. In the case of the IMD, only commands coming from authenticated
parties should be considered, while medical personnel should not trust any
message claiming to come from the IMD unless sufficient guarantees are
given.
Preserving the confidentiality of the information stored in and transmitted
by the IMD is another mandatory aspect. The device must implement
appropriate security policies that restrict what entities can reconfigure the
IMD or get access to the information stored in it, ensuring that only authorized
operations are executed. Similarly, security mechanisms have to
be implemented to protect the content of messages exchanged through an insecure wireless channel.
Integrity protection is equally important to ensure that information has
not been modified in transit. For example, if the information sent by the
implant to the Programmer is altered, the doctor might make a wrong decision.
Conversely, if a command sent to the implant is forged, modified,
or simply contains errors, its execution could result in a compromise of the
patient’s physical integrity.
Technical security mechanisms should be incorporated in the design
phase and complemented with appropriate legal and administrative measures.
Current legislation is rather permissive in this regard, allowing the
use of implants like ICDs that do not incorporate any security mechanisms.
Regulatory authorities like the FDA in the U.S or the EMA (European
Medicines Agency) in Europe should promote metrics and frameworks for
assessing the security of IMDs. These assessments should be mandatory
by law, requiring an adequate security level for an implant before approving
its use. Moreover, both the security measures supported on each IMD
and the security assessment results should be made public.
Prudent engineering practices well known in the safety and security domains
should be followed in the design of IMDs. If hardware errors are
detected, it often entails a replacement of the implant, with the associated
risks linked to a surgery. One of the main sources of failure when treating
or monitoring a patient is precisely malfunctions of the device itself.
These failures are known as “recalls” or “advisories”, and it is estimated
that they affect around 2.6% of patients carrying an implant. Furthermore,
the software running on the device should strictly support the functionalities
required to perform the medical and operational tasks for what it was
designed, and no more [66, 134, 213].
In Chapter 1, we present a survey of security and privacy issues in
IMDs, discuss the most relevant mechanisms proposed to address these
challenges, and analyze their suitability, advantages, and main drawbacks.
In Chapter 2, we show how the use of highly compressed electrocardiogram
(ECG) signals (only 24 coefficients of Hadamard Transform) is enough
to unequivocally identify individuals with a high performance (classification
accuracy of 97% and with identification system errors in the order of
10−2). In Chapter 3 we introduce a new Continuous Authentication scheme
that, contrarily to previous works in this area, considers ECG signals as
continuous data streams. The proposed ECG-based CA system is intended
for real-time applications and is able to offer an accuracy up to 96%, with
an almost perfect system performance (kappa statistic > 80%). In Chapter 4, we propose a distance bounding protocol to manage access control of
IMDs: ACIMD. ACIMD combines two features namely identity verification
(authentication) and proximity verification (distance checking). The
authentication mechanism we developed conforms to the ISO/IEC 9798-2
standard and is performed using the whole ECG signal of a device holder,
which is hardly replicable by a distant attacker. We evaluate the performance
of ACIMD using ECG signals of 199 individuals over 24 hours,
considering three adversary strategies. Results show that an accuracy of
87.07% in authentication can be achieved. Finally, in Chapter 5 we extract
some conclusions and summarize the published works (i.e., scientific
journals with high impact factor and prestigious international conferences).Los Dispositivos Médicos Implantables (DMIs) son dispositivos electrónicos
implantados dentro del cuerpo para tratar una enfermedad, controlar
el estado o mejorar el funcionamiento de alguna parte del cuerpo, o simplemente
para proporcionar al paciente una capacidad que no poseía antes
[86]. Ejemplos actuales de DMI incluyen marcapasos y desfibriladores
para monitorear y tratar afecciones cardíacas; neuroestimuladores para la
estimulación cerebral profunda en casos como la epilepsia o el Parkinson;
sistemas de administración de fármacos en forma de bombas de infusión; y
una variedad de biosensores para adquirir y procesar diferentes bioseñales.
Los DMIs más modernos han comenzado a incorporar numerosas funciones
de comunicación y redes (generalmente conocidas como telemetría)
así como capacidades de computación cada vez más sofisticadas. Esto
ha propiciado implantes con mayor inteligencia y pacientes con más autonomía,
ya que el personal médico puede acceder a los datos y reconfigurar
el implante de forma remota (es decir, sin que el paciente esté
físicamente presente en las instalaciones médicas). Aparte de una importante
reducción de costos, las capacidades de telemetría y cómputo también
permiten a los profesionales de la atención médica monitorear constantemente
la condición del paciente y desarrollar nuevas técnicas de diagnóstico
basadas en una Intra Body Network (IBN) de dispositivos médicos
[25, 26, 201].
Evolucionar desde un DMI electromecánico a uno con capacidades de
cómputo y de comunicación más avanzadas tiene muchos beneficios pero
también conlleva numerosos riesgos de seguridad y privacidad para el paciente.
La mayoría de estos riesgos son relativamente bien conocidos en los
escenarios clásicos de comunicaciones entre dispositivos, aunque en muchos
aspectos sus repercusiones son mucho más críticas en el caso de los
implantes. Los ataques contra un DMI pueden poner en riesgo la seguridad
del paciente que lo porta, con consecuencias fatales en ciertos casos.
Causar un mal funcionamiento intencionado en un implante puede causar
la muerte y, tal como lo reconoce la Food and Drug Administration (FDA)
de EE.UU, tales ataques deliberados podrían ser mucho más difíciles de
detectar que los ataques accidentales [61]. Además, estos dispositivos almacenan
y transmiten información médica muy delicada que requiere se
protegida, según lo dictado por las directivas europeas (por ejemplo, la Directiva 95/46/ECC) y estadunidenses (por ejemplo, la Directiva CFR
164.312) [94, 204].
Si bien todavía no se conocen incidentes reales, se han demostrado con
éxito varios ataques contra DMIs en el laboratorio [83, 133, 143]. Estos
ataques han demostrado cómo un adversario puede desactivar o reprogramar
terapias en un marcapasos con conectividad inalámbrica e incluso
inducir un estado de shock al paciente [65]. Otros ataques agotan
la batería y dejan al dispositivo inoperativo [91], lo que a menudo implica
que el paciente deba someterse a un procedimiento quirúrgico para reemplazar
la batería del DMI. Además, en el caso de los implantes cardíacos,
tienen un interruptor cuya posición de desconexión se consigue simplemente
aplicando un campo magnético intenso [149]. La existencia de este
mecanismo está motivada por la necesidad de proteger a los DMIs frete
a posibles campos electromagnéticos, por ejemplo, cuando el paciente se
somete a una cirugía cardíaca usando dispositivos de electrocauterización
[47]. Sin embargo, esto podría ser explotado fácilmente por un atacante,
ya que la activación de dicho mecanismo primitivo no requiere ningún tipo
de autenticación.
Garantizar la confidencialidad de la información almacenada y transmitida
por el DMI es otro aspecto obligatorio. El dispositivo debe implementar
políticas de seguridad apropiadas que restrinjan qué entidades
pueden reconfigurar el DMI o acceder a la información almacenada en él,
asegurando que sólo se ejecuten las operaciones autorizadas. De la misma
manera, mecanismos de seguridad deben ser implementados para proteger
el contenido de los mensajes intercambiados a través de un canal inalámbrico
no seguro.
La protección de la integridad es igualmente importante para garantizar
que la información no se haya modificado durante el tránsito. Por ejemplo,
si la información enviada por el implante al programador se altera, el
médico podría tomar una decisión equivocada. Por el contrario, si un comando
enviado al implante se falsifica, modifica o simplemente contiene
errores, su ejecución podría comprometer la integridad física del paciente.
Los mecanismos de seguridad deberían incorporarse en la fase de diseño
y complementarse con medidas legales y administrativas apropiadas.
La legislación actual es bastante permisiva a este respecto, lo que permite
el uso de implantes como marcapasos que no incorporen ningún mecanismo
de seguridad. Las autoridades reguladoras como la FDA en los Estados
Unidos o la EMA (Agencia Europea de Medicamentos) en Europa deberían
promover métricas y marcos para evaluar la seguridad de los DMIs.
Estas evaluaciones deberían ser obligatorias por ley, requiriendo un nivel
de seguridad adecuado para un implante antes de aprobar su uso. Además,
tanto las medidas de seguridad implementadas en cada DMI como los resultados
de la evaluación de su seguridad deberían hacerse públicos.
Buenas prácticas de ingeniería en los dominios de la protección y la
seguridad deberían seguirse en el diseño de los DMIs. Si se detectan errores
de hardware, a menudo esto implica un reemplazo del implante, con
los riesgos asociados y vinculados a una cirugía. Una de las principales
fuentes de fallo al tratar o monitorear a un paciente es precisamente el
mal funcionamiento del dispositivo. Estos fallos se conocen como “retiradas”,
y se estima que afectan a aproximadamente el 2,6 % de los pacientes
que llevan un implante. Además, el software que se ejecuta en el
dispositivo debe soportar estrictamente las funcionalidades requeridas para
realizar las tareas médicas y operativas para las que fue diseñado, y no más
[66, 134, 213].
En el Capítulo 1, presentamos un estado de la cuestión sobre cuestiones
de seguridad y privacidad en DMIs, discutimos los mecanismos más relevantes
propuestos para abordar estos desafíos y analizamos su idoneidad,
ventajas y principales inconvenientes. En el Capítulo 2, mostramos
cómo el uso de señales electrocardiográficas (ECGs) altamente comprimidas
(sólo 24 coeficientes de la Transformada Hadamard) es suficiente para
identificar inequívocamente individuos con un alto rendimiento (precisión
de clasificación del 97% y errores del sistema de identificación del orden
de 10−2). En el Capítulo 3 presentamos un nuevo esquema de Autenticación
Continua (AC) que, contrariamente a los trabajos previos en esta
área, considera las señales ECG como flujos de datos continuos. El sistema
propuesto de AC basado en señales cardíacas está diseñado para aplicaciones
en tiempo real y puede ofrecer una precisión de hasta el 96%,
con un rendimiento del sistema casi perfecto (estadístico kappa > 80 %).
En el Capítulo 4, proponemos un protocolo de verificación de la distancia
para gestionar el control de acceso al DMI: ACIMD. ACIMD combina
dos características, verificación de identidad (autenticación) y verificación
de la proximidad (comprobación de la distancia). El mecanismo de autenticación
es compatible con el estándar ISO/IEC 9798-2 y se realiza utilizando
la señal ECG con todas sus ondas, lo cual es difícilmente replicable
por un atacante que se encuentre distante. Hemos evaluado el rendimiento
de ACIMD usando señales ECG de 199 individuos durante 24 horas, y
hemos considerando tres estrategias posibles para el adversario. Los resultados
muestran que se puede lograr una precisión del 87.07% en la au tenticación. Finalmente, en el Capítulo 5 extraemos algunas conclusiones
y resumimos los trabajos publicados (es decir, revistas científicas con alto
factor de impacto y conferencias internacionales prestigiosas).Programa Oficial de Doctorado en Ciencia y Tecnología InformáticaPresidente: Arturo Ribagorda Garnacho.- Secretario: Jorge Blasco Alís.- Vocal: Jesús García López de Lacall
- …