271 research outputs found

    Optimized Hierarchical Power Oscillations Control for Distributed Generation Under Unbalanced Conditions

    Full text link
    Control structures have critical influences on converter-interfaced distributed generations (DG) under unbalanced conditions. Most of previous works focus on suppressing active power oscillations and ripples of DC bus voltage. In this paper, the relationship between amplitudes of the active power oscillations and the reactive power oscillations are firstly deduced and the hierarchical control of DG is proposed to reduce power oscillations. The hierarchical control consists of primary and secondary levels. Current references are generated in primary control level and the active power oscillations can be suppressed by a dual current controller. Secondary control reduces the active power and reactive power oscillations simultaneously by optimal model aiming for minimum amplitudes of oscillations. Simulation results show that the proposed secondary control with less injecting negative-sequence current than traditional control methods can effectively limit both active power and reactive power oscillations.Comment: Accepted by Applied Energ

    Control strategy of grid connected power converter based on virtual flux approach

    Get PDF
    A la portada consta el nom del programa interuniversitari: Joint Doctoral Programme in Electric Energy Systems [by the] Universidad de Málaga, Universidad de Sevilla, Universidad del País Vasco/Euskal Erriko Unibertsitatea i Universitat Politècnica de CatalunyaDistributed Generation (DG) provides an alternative to the Centralized Generation (CG) by means of generating electricity near to the end user of power with the employment of small-scale technologies to produce electricity, mainly using Renewable Energy Sources (RES). The prospects of renewable energy integration during the next years are still very optimistic. This PhD dissertation is made to provide an alternative control framework for the grid connected power converter by adopting the virtual flux concept in the control layer. This dissertation can be divided into three main topics. The 1st topic presents the voltage sensorless control system for the grid-connected power converter. The control system presented is done without depending on AC-voltage measurement where the grid synchronization is based on the Virtual Flux (VF) estimation. In this regard, the Frequency Locked Loop (FLL) is used in conjunction with the estimation scheme to make the system fully adaptive to the frequency changes. This voltage sensorless application is useful for reducing cost and complexity of the control hardware. It is also can be utilized in case of limited reliability or availability of voltage measurements at the intended point of synchronization to the grid. Considering that most previous studies are based on the VF estimation for the case of power converter connected to the grid through the L-filter or LC-filter, this dissertation is focused on the power converter connected to the grid through the LCL filter. The Proportional Resonant (PR) current controller is adopted in the inner loop control of the power electronics-based converter to test the performance of such system. Another control method based on VF synchronization that permits to control the active and reactive power delivery in a remote point of the grid is also presented in this dissertation. This is due to the fact that the VF is implemented that the voltage in a remote point of the line can be estimated. As it will be shown in simulations and experiments, the proposed control scheme provides a good tracking and dynamic performance under step changes in the reference power. The fast synchronization and the smooth reference tracking achieved in transient conditions have demonstrated the effectiveness of the Dual Second Order Generalized Integrator controlled as Quadrature Signal Generator (DSOGI-QSG) and also the current controller used in the proposed system. In addition to the power control itself, this study could also benefit the frequency and the voltage regulation methods in distributed generation applications as for instance in microgrid. Considering the fact that the grid connected power converter can be controlled as a virtual synchronous generator where the flux is a variable to be used for controlling its operation, this dissertation also presents a Virtual Synchronous Flux Controller (VSFC) as a new control framework of the grid connected power converter. In this regard, a new control strategy in the inner loop control of the power converter will be proposed. The main components of the outer loop control of VSFC are based on the active and reactive power control. The results presented show that the VSFC works well to control the active and reactive power without considering any synchronization system. The inner loop control is able to work as it is required, and the measurement flux is able to track the reference flux without any significant delays. All the work presented in this dissertation are supported by mathematical and simulation analysis. In order to endorse the conclusions achieved, a complete experimental validations have been conducted before wrapping this dissertation with a conclusion and recommendation for future enhancement of the control strategies that have been presented.Postprint (published version

    Advanced control methods on three-phase inverters in distributed energy resources

    Get PDF
    “This research is an endeavor to apply new and well-established control methodologies to improve transient response, stability and reliability of three-phase inverters in grid-connected and isolated mode of operation. In the course of studying the effect of these methodologies, model-based control is introduced and is extensively applied which is relatively a new approach. In addition, the application of this concept has been studied on developing “grid-forming” controls to allow wind and solar inverters to support voltage and frequency levels like traditional generators. This research encloses the details of three major works of this research and their possible contributions on improving the performance of three-phase inverters in gridconnected and isolated mode of operation. The first one employs the concept of adaptive control using multiple models and a hierarchical control approach to smoothly switch between isolated and grid-connected modes of operation. In the second work, the features of the first research work have been applied and more nourished to control a grid-forming unit. The interactions of this grid-supporting converter with a grid- forming unit is the main subject of discussion in this work. The last work applies the concept of internal-model control to introduce a new control methodology in power-synchronization method. This approach has tackled the non-minimum phase issue attributed to power-synchronization methodology and offers a robust solution. Furthermore, in this research, detailed stability analysis of all the proposed control structures have been presented. Along with all simulation verification, FPGA-Based Hardware-in-the-Loop (HIL) has been utilized to verify the performance of the discrete control structure. The details of plant modeling, controller design, HIL and experimental results are presented for all of the proposed schemes in each section”--Abstract, page iv

    Contributions to cascade linear control strategies applied to grid-connected Voltage-Source Converters

    Get PDF
    El trabajo desarrollado en esta Tesis se centra en optimizar el comportamiento de Voltage-Source Converters (VSCs) cuando son utilizados como interfaz con la red eléctrica, tanto para absorber como para entregar energía de la red con la mejor calidad posible y cumpliendo con los estándares. Para tal fin, esta Tesis se centra en el control de sistemas lineales conectados en cascada aplicados al control de VSCs conectados en paralelo con la red eléctrica a través de un filtro L, especialmente en conexiones con redes débiles y en dos líneas de trabajo: (i) seguimiento de armónicos de las corrientes de red y rechazo de armónicos de las tensiones de red, y (ii) control de la tensión del PCC en caso de desequilibrio. Para ello, esta Tesis realiza contribuciones en el área del control de corriente y control de la tensión del PCC. De entre las técnicas existentes para implementar el control de corriente para compensación armónica, dos de las más utilizadas son el control resonante y el control repetitivo, tanto en ejes de referencia estacionarios como síncronos. Se ha realizado un exhaustivo estudio de diferentes estructuras para implementar tales controles, mostrando su algoritmo adaptativo en frecuencia para cada una de ellas y analizando su carga computacional. Además, se han facilitado directrices básicas para su programación en un DSP. Se ha analizado también el esquema de control de corriente para establecer una comparación entre las diferentes estructuras. Después de estudiar en profundidad el control de corriente de un VSC conectado a la red eléctrica, el segundo control a analizar es el control de tensión del PCC. La presencia de una tensión desequilibrada en el PCC da lugar a la aparición de una componente de corriente de secuencia negativa, que deteriora el comportamiento del sistema de control cuando se emplean las técnicas de control convencionales. Los STATCOMs son bien conocidos por ser una aplicación de potencia capaz de llevar a cabo la regulación de la tensión en el PCC en líneas de distribución que pueden ser susceptibles de sufrir perturbaciones. Esta Tesis propone el uso de un controlador de tensión en ejes de referencia síncronos para compensar una tensión desequilibrada a través de un STATCOM, permitiendo controlar independientemente tanto la secuencia positiva como la secuencia negativa. Además, este controlador incluye aspectos como un mecanismo de antiwindup y droop control para mejorar su comportamiento. Se han realizado varias pruebas experimentales para analizar las características de los controladores de corriente abordados en esta Tesis. Todas ellas han sido realizadas bajo las mismas condiciones de potencia, tensión y corriente, de modo que se pueden extraer resultados comparativos. Estas pruebas pretenden caracterizar la respuesta transitoria, la respuesta en régimen permanente, el comportamiento frente a saltos de frecuencia y la carga computacional de los controladores de corriente estudiados

    Control Strategy for Microgrid Inverter under Unbalanced Grid Voltage Conditions

    Get PDF

    Grid Converters for Stationary Battery Energy Storage Systems

    Get PDF

    Design and Control of a Dynamic Voltage Restorer

    Get PDF

    Study and evaluation of distributed power electronic converters in photovoltaic generation applications

    Get PDF
    This research project has proposed a new modulation technique called “Local Carrier Pulse Width Modulation” (LC-PWM) for MMCs with different cell voltages, taking into account the measured cell voltages to generate switching sequences with more accurate timing. It also adapts the modulator sampling period to improve the transitions from level to level, an important issue to reduce noise at the internal circulating currents. As a result, the new modulation LC-PWM technique reduces the output distortion in a wider range of voltage situations. Furthermore, it effectively eliminates unnecessary AC components of circulating currents, resulting in lower power losses and higher MMC efficiency.Departamento de Tecnología ElectrónicaDoctorado en Ingeniería Industria
    corecore