3 research outputs found

    Quality assurance of quantitative cardiac T1-mapping in multicenter clinical trials - A T1 phantom program from the hypertrophic cardiomyopathy registry (HCMR) study.

    Get PDF
    BACKGROUND: Quantitative cardiovascular magnetic resonance T1-mapping is increasingly used for myocardial tissue characterization. However, the lack of standardization limits direct comparability between centers and wider roll-out for clinical use or trials. PURPOSE: To develop a quality assurance (QA) program assuring standardized T1 measurements for clinical use. METHODS: MR phantoms manufactured in 2013 were distributed, including ShMOLLI T1-mapping and reference T1 and T2 protocols. We first studied the T1 and T2 dependency on temperature and phantom aging using phantom datasets from a single site over 4 years. Based on this, we developed a multiparametric QA model, which was then applied to 78 scans from 28 other multi-national sites. RESULTS: T1 temperature sensitivity followed a second-order polynomial to baseline T1 values (R2 > 0.996). Some phantoms showed aging effects, where T1 drifted up to 49% over 40 months. The correlation model based on reference T1 and T2, developed on 1004 dedicated phantom scans, predicted ShMOLLI-T1 with high consistency (coefficient of variation 1.54%), and was robust to temperature variations and phantom aging. Using the 95% confidence interval of the correlation model residuals as the tolerance range, we analyzed 390 ShMOLLI T1-maps and confirmed accurate sequence deployment in 90%(70/78) of QA scans across 28 multiple centers, and categorized the rest with specific remedial actions. CONCLUSIONS: The proposed phantom QA for T1-mapping can assure correct method implementation and protocol adherence, and is robust to temperature variation and phantom aging. This QA program circumvents the need of frequent phantom replacements, and can be readily deployed in multicenter trials

    Multicontrast MRI registration of carotid arteries in atherosclerotic and normal subjects

    No full text

    Automated image segmentation and registration of vessel wall MRI for quantitative assessment of carotid artery vessel wall dimensions and plaque composition

    Get PDF
    The main goal of this thesis was to develop methods for automated segmentation, registration and classification of the carotid artery vessel wall and plaque components using multi-sequence MR vessel wall images to assess atherosclerosis. First, a general introduction into atherosclerosis and different stages of the disease were described including the importance to differentiate between stable and vulnerable plaques. Several non-invasive imaging techniques were discussed and the advantages of multi-sequence MRI were highlighted. Different novel automated image segmentation and registration techniques for analysis of the MRI images have been developed. A 3D vessel model to automatically segment the vessel wall was presented. Automated image registration was applied to correct for patient movement during the acquisition of an MRI scan and between MRI scans. The last topic is the automatic classification of the different plaque components which can be present inside the vessel wall. All techniques were developed and validated using relevant patient data and reference standards. The work presented is an important contribution to the automated analysis of multi-sequence MR vessel wall imaging of the carotid artery. These techniques can speed up the current manual analysis and are potentially more accurate and more reproducible.ASCI research school. Bontius Stichting inz. Doelfonds beeldverwerking. Library of the University of Leiden. Medis medical imaging systems bv, Leiden. Pie Medical Imaging BV, MaastrichtUBL - phd migration 201
    corecore