396 research outputs found

    Radiofrequency ablation of small liver malignancies under magnetic resonance guidance: progress in targeting and preliminary observations with temperature monitoring

    Get PDF
    Objectives: To evaluate the feasibility and effectiveness of magnetic resonance (MR)-guided radiofrequency (RF) ablation for small liver tumours with poor conspicuity on both contrast-enhanced ultrasonography (US) and computed tomography (CT), using fast navigation and temperature monitoring. Methods: Sixteen malignant liver nodules (long-axis diameter, 0.6-2.4cm) were treated with multipolar RF ablation on a 1.5-T wide-bore MR system in ten patients. Targeting was performed interactively, using a fast steady-state free precession sequence. Real-time MR-based temperature mapping was performed, using gradient echo-echo planar imaging (GRE-EPI) and hardware filtering. MR-specific treatment data were recorded. The mean follow-up time was 19 ± 7months. Results: Correct placement of RF electrodes was obtained in all procedures (image update, <500ms; mean targeting time, 21 ± 11min). MR thermometry was available for 14 of 16 nodules (88%) with an accuracy of 1.6°C in a non-heated region. No correlation was found between the size of the lethal thermal dose and the ablation zone at follow-up imaging. The primary and secondary effectiveness rates were 100% and 91%, respectively. Conclusions: RF ablation of small liver tumours can be planned, targeted, monitored and controlled with MR imaging within acceptable procedure times. Temperature mapping is technically feasible, but the clinical benefit remains to be prove

    Crepuscular Rays for Tumor Accessibility Planning

    Get PDF

    A prospective multicentre trial on survival after Microwave Ablation VErsus Resection for Resectable Colorectal liver metastases (MAVERRIC).

    Get PDF
    AIM This multi-centre prospective cohort study aimed to investigate non-inferiority in patients' overall survival when treating potentially resectable colorectal cancer liver metastasis (CRLM) with stereotactic microwave ablation (SMWA) as opposed to hepatic resection (HR). METHODS Patients with no more than 5 CRLM no larger than 30 mm, deemed eligible for both SMWA and hepatic resection at the local multidisciplinary team meetings, were deliberately treated with SMWA (study group). The contemporary control group consisted of patients with no more than 5 CRLM, none larger than 30 mm, treated with HR, extracted from a prospectively maintained nationwide Swedish database. After propensity-score matching, 3-year overall survival (OS) was compared as the primary outcome using Kaplan-Meier and Cox regression analyses. RESULTS All patients in the study group (n = 98) were matched to 158 patients from the control group (mean standardised difference in baseline covariates = 0.077). OS rates at 3 years were 78% (Confidence interval [CI] 68-85%) after SMWA versus 76% (CI 69-82%) after HR (stratified Log-rank test p = 0.861). Estimated 5-year OS rates were 56% (CI 45-66%) versus 58% (CI 50-66%). The adjusted hazard ratio for treatment type was 1.020 (CI 0.689-1.510). Overall and major complications were lower after SMWA (percentage decrease 67% and 80%, p < 0.01). Hepatic retreatments were more frequent after SMWA (percentage increase 78%, p < 0.01). CONCLUSION SMWA is a valid curative-intent treatment alternative to surgical resection for small resectable CRLM. It represents an attractive option in terms of treatment-related morbidity with potentially wider options regarding hepatic retreatments over the future course of disease

    Preoperative trajectory planning for percutaneous procedures in deformable environments

    Get PDF
    International audienceIn image-guided percutaneous interventions, a precise planning of the needle path is a key factor to a successful intervention. In this paper we propose a novel method for computing a patient-specific optimal path for such interventions, accounting for both the deformation of the needle and soft tissues due to the insertion of the needle in the body. To achieve this objective, we propose an optimization method for estimating preoperatively a curved trajectory allowing to reach a target even in the case of tissue motion and needle bending. Needle insertions are simulated and regarded as evaluations of the objective function by the iterative planning process. In order to test the planning algorithm, it is coupled with a fast needle insertion simulation involving a flexible needle model and soft tissue finite element modeling, and experimented on the use-case of thermal ablation of liver tumors. Our algorithm has been successfully tested on twelve datasets of patient-specific geometries. Fast convergence to the actual optimal solution has been shown. This method is designed to be adapted to a wide range of percutaneous interventions

    Stereotactic and Robotic Minimally Invasive Thermal Ablation of Malignant Liver Tumors: A Systematic Review and Meta-Analysis.

    Get PDF
    Background Stereotactic navigation techniques aim to enhance treatment precision and safety in minimally invasive thermal ablation of liver tumors. We qualitatively reviewed and quantitatively summarized the available literature on procedural and clinical outcomes after stereotactic navigated ablation of malignant liver tumors. Methods A systematic literature search was performed on procedural and clinical outcomes when using stereotactic or robotic navigation for laparoscopic or percutaneous thermal ablation. The online databases Medline, Embase, and Cochrane Library were searched. Endpoints included targeting accuracy, procedural efficiency, and treatment efficacy outcomes. Meta-analysis including subgroup analyses was performed. Results Thirty-four studies (two randomized controlled trials, three prospective cohort studies, 29 case series) were qualitatively analyzed, and 22 studies were included for meta-analysis. Weighted average lateral targeting error was 3.7 mm (CI 3.2, 4.2), with all four comparative studies showing enhanced targeting accuracy compared to free-hand targeting. Weighted average overall complications, major complications, and mortality were 11.4% (6.7, 16.1), 3.4% (2.1, 5.1), and 0.8% (0.5, 1.3). Pooled estimates of primary technique efficacy were 94% (89, 97) if assessed at 1-6 weeks and 90% (87, 93) if assessed at 6-12 weeks post ablation, with remaining between-study heterogeneity. Primary technique efficacy was significantly enhanced in stereotactic vs. free-hand targeting, with odds ratio (OR) of 1.9 (1.2, 3.2) (n = 6 studies). Conclusions Advances in stereotactic navigation technologies allow highly precise and safe tumor targeting, leading to enhanced primary treatment efficacy. The use of varying definitions and terminology of safety and efficacy limits comparability among studies, highlighting the crucial need for further standardization of follow-up definitions

    Prediction of Ablation Volume in Percutaneous Lung Microwave Ablation: A Single Centre Retrospective Study

    Get PDF
    Background: Percutaneous Microwave Ablation (MWA) of lung malignancies is a procedure with many technical challenges, among them the risk of residual disease. Recently, dedicated software able to predict the volume of the ablated area was introduced. Cone-beam computed tomography (CBCT) is the imaging guidance of choice for pulmonary ablation in our institution. The volumetric prediction software (VPS) has been installed and used in combination with CBCT to check the correct position of the device. Our study aimed to compare the results of MWA of pulmonary tumours performed using CBCT with and without VPS. Methods: We retrospectively reviewed 1-month follow-up enhanced contrast-enhanced computed tomography (CECT) scans of 10 patients who underwent ablation with the assistance of VPS (group 1) and of 10 patients who were treated without the assistance of VPS (group 2). All patients were treated for curative purposes, the maximum axial diameter of lesions ranged between 5 and 22 mm in group 1 and between 5 and 25 mm in group 2. We compared the presence of residual disease between the two groups. Results: In group 1 residual disease was seen in only 1 patient (10%) in which VPS had ensured complete coverage of the tumour. In group 2 residual disease was found in 3 patients (30%). Conclusions: Using this software during MWA of lung malignancies could improve the efficacy of the treatment compared to the conventional only CBCT guidance

    Interventional Radiology and the Care of the Oncology Patient

    Get PDF
    Interventional Radiology (IR) is occupying an increasingly prominent role in the care of patients with cancer, with involvement from initial diagnosis, right through to minimally invasive treatment of the malignancy and its complications. Adequate diagnostic samples can be obtained under image guidance by percutaneous biopsy and needle aspiration in an accurate and minimally invasive manner. IR techniques may be used to place central venous access devices with well-established safety and efficacy. Therapeutic applications of IR in the oncology patient include local tumour treatments such as transarterial chemo-embolisation and radiofrequency ablation, as well as management of complications of malignancy such as pain, organ obstruction, and venous thrombosis

    Design-centric Method for an Augmented Reality Robotic Surgery

    Get PDF
    Master'sMASTER OF ENGINEERIN
    corecore