939 research outputs found

    Time domain functional NIRS imaging for human brain mapping

    Get PDF
    AbstractThis review is aimed at presenting the state-of-the-art of time domain (TD) functional near-infrared spectroscopy (fNIRS). We first introduce the physical principles, the basics of modeling and data analysis. Basic instrumentation components (light sources, detection techniques, and delivery and collection systems) of a TD fNIRS system are described. A survey of past, existing and next generation TD fNIRS systems used for research and clinical studies is presented. Performance assessment of TD fNIRS systems and standardization issues are also discussed. Main strengths and weakness of TD fNIRS are highlighted, also in comparison with continuous wave (CW) fNIRS. Issues like quantification of the hemodynamic response, penetration depth, depth selectivity, spatial resolution and contrast-to-noise ratio are critically examined, with the help of experimental results performed on phantoms or in vivo. Finally we give an account on the technological developments that would pave the way for a broader use of TD fNIRS in the neuroimaging community

    New Horizons in Time-Domain Diffuse Optical Spectroscopy and Imaging

    Get PDF
    Jöbsis was the first to describe the in vivo application of near-infrared spectroscopy (NIRS), also called diffuse optical spectroscopy (DOS). NIRS was originally designed for the clinical monitoring of tissue oxygenation, and today it has also become a useful tool for neuroimaging studies (functional near-infrared spectroscopy, fNIRS). However, difficulties in the selective and quantitative measurements of tissue hemoglobin (Hb), which have been central in the NIRS field for over 40 years, remain to be solved. To overcome these problems, time-domain (TD) and frequency-domain (FD) measurements have been tried. Presently, a wide range of NIRS instruments are available, including commonly available commercial instruments for continuous wave (CW) measurements, based on the modified Beer–Lambert law (steady-state domain measurements). Among these measurements, the TD measurement is the most promising approach, although compared with CW and FD measurements, TD measurements are less common, due to the need for large and expensive instruments with poor temporal resolution and limited dynamic range. However, thanks to technological developments, TD measurements are increasingly being used in research, and also in various clinical settings. This Special Issue highlights issues at the cutting edge of TD DOS and diffuse optical tomography (DOT). It covers all aspects related to TD measurements, including advances in hardware, methodology, the theory of light propagation, and clinical applications

    Multiple Scattering Of Light In Inhomogeneous Media And Applications

    Get PDF
    Light scattering-based techniques are being developed for non-invasive diagnostics of inhomogeneous media in various fields, such as medicine, biology, and material characterization. However, as most media of interest are highly scattering and have a complex structure, it is difficult to obtain a full analytical solution of the scattering problem without introducing approximations and assumptions about the properties of the system under consideration. Moreover, most of the previous studies deal with idealized scattering situations, rarely encountered in practice. This dissertation provides new analytical, numerical, and experimental solutions to describe subtle effects introduced by the properties of the light sources, and by the boundaries, absorption and morphology of the investigated media. A novel Monte Carlo simulation was developed to describe the statistics of partially coherent beams after propagation through inhomogeneous media. The Monte Carlo approach also enabled us to study the influence of the refractive index contrast on the diffusive processes, to discern between different effects of absorption in multiple scattering, and to support experimental results on inhomogeneous media with complex morphology. A detailed description of chromatic effects in scattering was used to develop new models that explain the spectral dependence of the detected signal in applications such as imaging and diffuse reflectance measurements. The quantitative and non-invasive characterization of inhomogeneous media with complex structures, such as porous membranes, diffusive coatings, and incipient lesions in natural teeth was then demonstrated

    New frontiers in time-domain diffuse optics, a review

    Get PDF
    The recent developments in time-domain diffuse optics that rely on physical concepts (e.g., time-gating and null distance) and advanced photonic components (e.g., vertical cavity source-emitting laser as light sources, single photon avalanche diode, and silicon photomultipliers as detectors, fast-gating circuits, and time-to-digital converters for acquisition) are focused. This study shows how these tools could lead on one hand to compact and wearable time-domain devices for point-of-care diagnostics down to the consumer level and on the other hand to powerful systems with exceptional depth penetration and sensitivity

    Towards next generation time-domain diffuse optics devices

    Get PDF
    Diffuse Optics is growing in terms of applications ranging from e.g. oximetry, to mammography, molecular imaging, quality assessment of food and pharmaceuticals, wood optics, physics of random media. Time-domain (TD) approaches, although appealing in terms of quantitation and depth sensibility, are presently limited to large fiber-based systems, with limited number of source-detector pairs. We present a miniaturized TD source-detector probe embedding integrated laser sources and single-photon detectors. Some electronics are still external (e.g. power supply, pulse generators, timing electronics), yet full integration on-board using already proven technologies is feasible. The novel devices were successfully validated on heterogeneous phantoms showing performances comparable to large state-of-the-art TD rack-based systems. With an investigation based on simulations we provide numerical evidence that the possibility to stack many TD compact source-detector pairs in a dense, null source-detector distance arrangement could yield on the brain cortex about 1 decade higher contrast as compared to a continuous wave (CW) approach. Further, a 3-fold increase in the maximum depth (down to 6 cm) is estimated, opening accessibility to new organs such as the lung or the heart. Finally, these new technologies show the way towards compact and wearable TD probes with orders of magnitude reduction in size and cost, for a widespread use of TD devices in real life

    Advances in Hyperspectral and Multispectral Optical Spectroscopy and Imaging of Tissue

    Get PDF
    The purpose of this SI is to provide an overview of recent advances made in the methods used for tissue imaging and characterization, which benefit from using a large range of optical wavelengths. Guerouah et al. has contributed a profound study of the responses of the adult human brain to breath-holding challenges based on hyperspectral near-infrared spectroscopy (hNIRS). Lange et al. contributed a timely and comprehensive review of the features and biomedical and clinical applications of supercontinuum laser sources. Blaney et al. reported the development of a calibration-free hNIRS system that can measure the absolute and broadband absorption and scattering spectra of turbid media. Slooter et al. studied the utility of measuring multiple tissue parameters simultaneously using four optical techniques operating at different wavelengths of light—optical coherence tomography (1300 nm), sidestream darkfield microscopy (530 nm), laser speckle contrast imaging (785 nm), and fluorescence angiography (~800 nm)—in the gastric conduit during esophagectomy. Caredda et al. showed the feasibility of accurately quantifying the oxy- and deoxy-hemoglobin and cytochrome-c-oxidase responses to neuronal activation and obtaining spatial maps of these responses using a setup consisting of a white light source and a hyperspectral or standard RGB camera. It is interest for the developers and potential users of clinical brain and tissue optical monitors, and for researchers studying brain physiology and functional brain activity

    Effects of time-gated detection in diffuse optical imaging at short source-detector separation

    Get PDF
    The adoption of a short source-detector distance, combined with a time-resolved acquisition, can be advantageous in diffuse optical imaging due to the stricter spatial localization of the probing photons, provided that the strong burst of early photons is suppressed using a time-gated detection scheme. We propose a model for predicting the effect of the time-gated measurement system using a time-variant operator built on the system response acquired at different gate delays. The discrete representation of the system operator, termed Spread Matrix, can be analyzed to identify the bottlenecks of the detection system with respect to the physical problem under study. Measurements performed on tissue phantoms, using a time-gated single-photon avalanche diode and an interfiber distance of 2 mm, demonstrate that inhomogeneities down to 3 cm can be detected only if the decay constant of the detector is lower than 100 ps, while the transient opening of the gate has a less critical impact

    The Use of Supercontinuum Laser Sources in Biomedical Diffuse Optics: Unlocking the Power of Multispectral Imaging

    Get PDF
    Optical techniques based on diffuse optics have been around for decades now and are making their way into the day-to-day medical applications. Even though the physics foundations of these techniques have been known for many years, practical implementation of these technique were hindered by technological limitations, mainly from the light sources and/or detection electronics. In the past 20 years, the developments of supercontinuum laser (SCL) enabled to unlock some of these limitations, enabling the development of system and methodologies relevant for medical use, notably in terms of spectral monitoring. In this review, we focus on the use of SCL in biomedical diffuse optics, from instrumentation and methods developments to their use for medical applications. A total of 95 publications were identified, from 1993 to 2021. We discuss the advantages of the SCL to cover a large spectral bandwidth with a high spectral power and fast switching against the disadvantages of cost, bulkiness, and long warm up times. Finally, we summarize the utility of using such light sources in the development and application of diffuse optics in biomedical sciences and clinical applications

    Mechanically switchable solid inhomogeneous phantom for performance tests in diffuse imaging and spectroscopy

    Get PDF
    A mechanically switchable solid inhomogeneous phantom simulating localized absorption changes was developed and characterized. The homogeneous host phantom was made of epoxy resin with black toner and titanium dioxide particles added as absorbing and scattering components, respectively. A cylindrical rod, movable along a hole in the block and made of the same material, has a black polyvinyl chloride cylinder embedded in its center. By varying the volume and position of the black inclusion, absorption perturbations can be generated over a large range of magnitudes. The phantom has been characterized by various time-domain diffuse optics instruments in terms of absorption and scattering spectra, transmittance images, and reflectance contrast. Addressing a major application of the phantom for performance characterization for functional near-infrared spectroscopy of the brain, the contrast was measured in reflectance mode while black cylinders of volumes from ≈20 mm3 to ≈270 mm3 were moved in lateral and depth directions, respectively. The new type of solid inhomogeneous phantom is expected to become a useful tool for routine quality check of clinical instruments or implementation of industrial standards provided an experimental characterization of the phantom is performed in advance
    • …
    corecore