5 research outputs found

    A Lumped-Mass Model for Large Deformation Continuum Surfaces Actuated by Continuum Robotic Arms

    Get PDF
    Currently, flexible surfaces enabled to be actuated by robotic arms are experiencing high interest and demand for robotic applications in various areas such as healthcare, automotive , aerospace, and manufacturing. However, their design and control thus far has largely been based on "trial and error" methods requiring multiple trials and/or high levels of user specialization. Robust methods to realize flexible surfaces with the ability to deform into large curvatures therefore require a reliable, validated model that takes into account many physical and mechanical properties including elasticity, material characteristics, gravity, external forces, and thickness shear effects. The derivation of such a model would then enable the further development of predictive-based control methods for flexible robotic surfaces. This paper presents a lumped-mass model for flexible surfaces undergoing large deformation due to actuation by continuum robotic arms. The resulting model includes mechanical and physical properties for both the surface and actuation elements to predict deformation in multiple curvature directions and actuation configurations. The model is validated against an experimental system where measured displacements between the experimental and modeling results showed considerable agreement with a mean error magnitude of about 1% of the length of the surface at the final deformed shapes

    On the Dependency of the Electromechanical Response of Rotary MEMS/NEMS on Their Embedded Flexure Hinges’ Geometry

    Get PDF
    This paper investigates how the electromechanical response of MEMS/NEMS devices changes when the geometrical characteristics of their embedded flexural hinges are modified. The research is dedicated particularly to MEMS/NEMS devices which are actuated by means of rotary comb-drives. The electromechanical behavior of a chosen rotary device is assessed by studying the rotation of the end effector, the motion of the comb-drive mobile fingers, the actuator’s maximum operating voltage, and the stress sustained by the flexure when the flexure’s shape, length, and width change. The results are compared with the behavior of a standard revolute joint. Outcomes demonstrate that a linear flexible beam cannot perfectly replace the revolute joint as it induces a translation that strongly facilitates the pull-in phenomenon and significantly increases the risk of ruptures of the comb-drives. On the other hand, results show how curved beams provide a motion that better resembles the revolute motion, preserving the structural integrity of the device and avoiding the pull-in phenomenon. Finally, results also show that the end effector motion approaches most precisely the revolute motion when a fine tuning of the beam’s length and width is performed

    Modeling, Analysis, Force Sensing and Control of Continuum Robots for Minimally Invasive Surgery

    Get PDF
    This dissertation describes design, modeling and application of continuum robotics for surgical applications, specifically parallel continuum robots (PCRs) and concentric tube manipulators (CTMs). The introduction of robotics into surgical applications has allowed for a greater degree of precision, less invasive access to more remote surgical sites, and user-intuitive interfaces with enhanced vision systems. The most recent developments have been in the space of continuum robots, whose exible structure create an inherent safety factor when in contact with fragile tissues. The design challenges that exist involve balancing size and strength of the manipulators, controlling the manipulators over long transmission pathways, and incorporating force sensing and feedback from the manipulators to the user. Contributions presented in this work include: (1) prototyping, design, force sensing, and force control investigations of PCRs, and (2) prototyping of a concentric tube manipulator for use in a standard colonoscope. A general kinetostatic model is presented for PCRs along with identification of multiple physical constraints encountered in design and construction. Design considerations and manipulator capabilities are examined in the form of matrix metrics and ellipsoid representations. Finally, force sensing and control are explored and experimental results are provided showing the accuracy of force estimates based on actuation force measurements and control capabilities. An overview of the design requirements, manipulator construction, analysis and experimental results are provided for a CTM used as a tool manipulator in a traditional colonoscope. Currently, tools used in colonoscopic procedures are straight and exit the front of the scope with 1 DOF of operation (jaws of a grasper, tightening of a loop, etc.). This research shows that with a CTM deployed, the dexterity of these tools can be increased dramatically, increasing accuracy of tool operation, ease of use and safety of the overall procedure. The prototype investigated in this work allows for multiple tools to be used during a single procedure. Experimental results show the feasibility and advantages of the newly-designed manipulators

    DEVELOPMENT OF A KINETIC MODEL FOR STEERABLE CATHETERS FOR MINIMALLY INVASIVE SURGERY

    Get PDF
    The steerable catheters have demonstrated many advantages to overcome the limitations of the conventional catheters in the minimally invasive surgery. The motion and force transmission from the proximal end to distal tip of the catheter have significant effects to the efficiency and safety of surgery. While the force information between the catheter and the body (e.g., vessel) can be obtained by mounting sensors on the distal tip of the catheter, this would be more intrusive and less reliable than the one without the sensors, which is described in this disseration. In addition, the small diameters of the catheters may also restrict the idea of mounting sensors on the distal tip. The other approach to obtain the force information is to infer it from the information outside the body. This will demand an accurate mathematical model that describes the force and motion relation called kinetic model, and unfortunately, such a kinetic model is not available in the literature. In this dissertation, a kinetic model for steerable catheters is presented wich captures the following characteristics of the steerable catheter, namely (1) the geometrical non-linear behavior of the catheter in motion, (2) the deformable pathway, (3) the friction between the catheter and the pathyway, and (4) the contact between the catheter and pathway. A non-linear finite element system (SPACAR) was employed to capture these characteristics. A test-bed was built and an experiment was carried out to verify the developed kinetic model. The following conclusions can be drawn from this dissertation: (1) the developed kinetic model is accurte in comparison with those in literature; (2) the Dahl friction model, the LuGre friction model and the simplified LuGre friction model are able to capture the friction behavior between the catheter and the pathway but the Coulomb friction model fails (as it cannot capture the hysteresis property which has a significant influence on the behavior of the catheter); (3) the developed kinetic model has the potential of being used to optimize the design and operation of steerable catheters with several salient findings that (3a) the maximal contact force between the catheter and the pathway occurs on the tip of the distal part or the connecting part between the distal part and catheter body of the catheter and (3b) the rigidity and length of the distal part are crucial structural parameters that affect the motion and force transmission significantly. There are several contributions made by this dissertation. In the field of the steerable catheter, biomechanics and bio-instrumentation, the contributions are summarized in the following: (1) the approach to develop the kinetic model of the steerable catheter in a complex work environment is useful to model other similar compliant medical devices, such as endoscope; (2) the kinetic model of the steerable catheter can provide the force information to improve the efficiency and safety of MIS (minimally invastive surgery) and to realize the “doctor-assisted” catheter-based MIS procedure; (3) the kinetic model can provide accurate data for developing other simplified models for the steerable catheters in their corresponding work environments for realizing the robotic-based fully automated MIS procedure. (4) The kinetic model of the steerable catheter and the test-bed with the corresponding instruments and methods for the kinetic and kinematic measurements are a useful design validation in the steerable catheter technology as well as for the training of physicians to perform the catheter-based interventional procedure by adding more complex anatomic phantoms. In the field of continuum manipulator and continuum robots, the approach to develop the kinetic model is useful to model other manipulators and robots, such as snake-like robots
    corecore