5,010 research outputs found

    Maintenance of head and neck tumor on-chip: gateway to personalized treatment?

    Get PDF
    Aim: Head and neck squamous cell carcinomas (HNSCC) are solid tumors with low overall survival (40–60%). In a move toward personalized medicine, maintenance of tumor biopsies in microfluidic tissue culture devices is being developed. Methodology/ results: HNSCC (n = 15) was dissected (5–10 mg) and either analyzed immediately or cultured in a microfluidic device (37°C) for 48 h. No difference was observed in morphology between pre- and postculture specimens. Dissociated samples were analyzed using trypan blue exclusion (viability), propidium iodide flow cytometry (death) and MTS assay (proliferation) with no significant difference observed highlighting tissue maintenance. Computational fluid dynamics showed laminar flow within the system. Conclusion: The microfluidic culture system successfully maintained HNSCC for 48 h, the culture system will allow testing of different treatment modalities with response monitoring. Lay abstract: Head and neck cancers often have a poor treatment outcome. In order to study the response of the tissue, a miniaturized culture system has been developed to keep a small piece of tumor alive. In the current study, we show that small pieces of cancer tissue can be maintained in the system, using tissue structure and viability of single cells as a guide. In future work, patient equivalent treatments can be applied to these microculture systems to investigate individual patient tumor responses, which could help to guide treatment selection

    Flow dynamics control the effect of sphingosine-1-phosphate on endothelial permeability in a microfluidic vessel bifurcation model

    Get PDF
    Blood vessels are lined by endothelial cells that form a semipermeable barrier to restrict fluid flow across the vessel wall. The endothelial barrier is known to respond to various molecular mechanisms, but the effects of mechanical signals that arise due to blood flow remain poorly understood. Here, we report a microfluidic model that mimics the flow conditions and endothelial/extracellular matrix (ECM) architecture of a vessel bifurcation to enable systematic investigation of how flow dynamics that arise within bifurcating vessels guides the endothelial response to biochemical signals. Applying the strengths of our system, we further investigate the endothelial response to sphingosine-1-phosphate, a bioactive lipid that has demonstrated flow-dependent regulation of vascular permeability. We demonstrate that bifurcated fluid flow (BFF) that arises at the base of vessel bifurcations and laminar shear stress (LSS) that arises along downstream vessel walls induce a decrease in endothelial permeability. Furthermore, we identify that flow-dynamics and chaperone proteins regulate the endothelial response to S1P. Through pharmacological inhibition of S1P receptors 1 and 2, we report ligand-independent mechanical activation of S1P receptors 1 and 2, providing support for the role of G protein-coupled receptors as mechanosensors. These findings introduce BFF as an important regulator of vascular permeability, and establish flow dynamics as a determinant of the endothelial response to S1P.Pelotonia Fellowship ProgramBarry M. Goldwater Excellence in Education FoundationThe Ohio State University College of EngineeringA one-year embargo was granted for this item.Academic Major: Biomedical Engineerin

    Heterogeneity in pure microbial systems: experimental measurements and modeling

    Get PDF
    Cellular heterogeneity influences bioprocess performance in ways that until date are not completely elucidated. In order to account for this phenomenon in the design and operation of bioprocesses, reliable analytical and mathematical descriptions are required. We present an overview of the single cell analysis, and the mathematical modeling frameworks that have potential to be used in bioprocess control and optimization, in particular for microbial processes. In order to be suitable for bioprocess monitoring, experimental methods need to be high throughput and to require relatively short processing time. One such method used successfully under dynamic conditions is flow cytometry. Population balance and individual based models are suitable modeling options, the latter one having in particular a good potential to integrate the various data collected through experimentation. This will be highly beneficial for appropriate process design and scale up as a more rigorous approach may prevent a priori unwanted performance losses. It will also help progressing synthetic biology applications to industrial scale

    Optimization of Microfluidic Particle Separator Geometry Using Computational Fluid Dynamics

    Get PDF
    Computational fluid dynamics software was used to simulate the motion of circulating tumor cells in a variety of microfluidic cell isolation devices. Design of several novel microfluidic cell isolation devices was aided by viewing streamlines of fluid in devices in simulation. Devices that performed best in simulation used 5-micrometer wide guiding channels to guide cells to the capture location in the device. While these devices performed better than other devices in simulation and captured all particles regardless of position along inlet, experimental results differ from simulation
    • …
    corecore