14,468 research outputs found
Mesh-to-raster based non-rigid registration of multi-modal images
Region of interest (ROI) alignment in medical images plays a crucial role in
diagnostics, procedure planning, treatment, and follow-up. Frequently, a model
is represented as triangulated mesh while the patient data is provided from CAT
scanners as pixel or voxel data. Previously, we presented a 2D method for
curve-to-pixel registration. This paper contributes (i) a general
mesh-to-raster (M2R) framework to register ROIs in multi-modal images; (ii) a
3D surface-to-voxel application, and (iii) a comprehensive quantitative
evaluation in 2D using ground truth provided by the simultaneous truth and
performance level estimation (STAPLE) method. The registration is formulated as
a minimization problem where the objective consists of a data term, which
involves the signed distance function of the ROI from the reference image, and
a higher order elastic regularizer for the deformation. The evaluation is based
on quantitative light-induced fluoroscopy (QLF) and digital photography (DP) of
decalcified teeth. STAPLE is computed on 150 image pairs from 32 subjects, each
showing one corresponding tooth in both modalities. The ROI in each image is
manually marked by three experts (900 curves in total). In the QLF-DP setting,
our approach significantly outperforms the mutual information-based
registration algorithm implemented with the Insight Segmentation and
Registration Toolkit (ITK) and Elastix
Atlas-Based Prostate Segmentation Using an Hybrid Registration
Purpose: This paper presents the preliminary results of a semi-automatic
method for prostate segmentation of Magnetic Resonance Images (MRI) which aims
to be incorporated in a navigation system for prostate brachytherapy. Methods:
The method is based on the registration of an anatomical atlas computed from a
population of 18 MRI exams onto a patient image. An hybrid registration
framework which couples an intensity-based registration with a robust
point-matching algorithm is used for both atlas building and atlas
registration. Results: The method has been validated on the same dataset that
the one used to construct the atlas using the "leave-one-out method". Results
gives a mean error of 3.39 mm and a standard deviation of 1.95 mm with respect
to expert segmentations. Conclusions: We think that this segmentation tool may
be a very valuable help to the clinician for routine quantitative image
exploitation.Comment: International Journal of Computer Assisted Radiology and Surgery
(2008) 000-99
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
Prior-based Coregistration and Cosegmentation
We propose a modular and scalable framework for dense coregistration and
cosegmentation with two key characteristics: first, we substitute ground truth
data with the semantic map output of a classifier; second, we combine this
output with population deformable registration to improve both alignment and
segmentation. Our approach deforms all volumes towards consensus, taking into
account image similarities and label consistency. Our pipeline can incorporate
any classifier and similarity metric. Results on two datasets, containing
annotations of challenging brain structures, demonstrate the potential of our
method.Comment: The first two authors contributed equall
Evaluation of Motion Artifact Metrics for Coronary CT Angiography
Purpose
This study quantified the performance of coronary artery motion artifact metrics relative to human observer ratings. Motion artifact metrics have been used as part of motion correction and bestâphase selection algorithms for Coronary Computed Tomography Angiography (CCTA). However, the lack of ground truth makes it difficult to validate how well the metrics quantify the level of motion artifact. This study investigated five motion artifact metrics, including two novel metrics, using a dynamic phantom, clinical CCTA images, and an observer study that provided groundâtruth motion artifact scores from a series of pairwise comparisons. Method
Five motion artifact metrics were calculated for the coronary artery regions on both phantom and clinical CCTA images: positivity, entropy, normalized circularity, Fold Overlap Ratio (FOR), and LowâIntensity Region Score (LIRS). CT images were acquired of a dynamic cardiac phantom that simulated cardiac motion and contained six iodineâfilled vessels of varying diameter and with regions of soft plaque and calcifications. Scans were repeated with different gantry start angles. Images were reconstructed at five phases of the motion cycle. Clinical images were acquired from 14 CCTA exams with patient heart rates ranging from 52 to 82 bpm. The vessel and shading artifacts were manually segmented by three readers and combined to create groundâtruth artifact regions. Motion artifact levels were also assessed by readers using a pairwise comparison method to establish a groundâtruth reader score. The Kendall\u27s Tau coefficients were calculated to evaluate the statistical agreement in ranking between the motion artifacts metrics and reader scores. Linear regression between the reader scores and the metrics was also performed. Results
On phantom images, the Kendall\u27s Tau coefficients of the five motion artifact metrics were 0.50 (normalized circularity), 0.35 (entropy), 0.82 (positivity), 0.77 (FOR), 0.77(LIRS), where higher Kendall\u27s Tau signifies higher agreement. The FOR, LIRS, and transformed positivity (the fourth root of the positivity) were further evaluated in the study of clinical images. The Kendall\u27s Tau coefficients of the selected metrics were 0.59 (FOR), 0.53 (LIRS), and 0.21 (Transformed positivity). In the study of clinical data, a Motion Artifact Score, defined as the product of FOR and LIRS metrics, further improved agreement with reader scores, with a Kendall\u27s Tau coefficient of 0.65. Conclusion
The metrics of FOR, LIRS, and the product of the two metrics provided the highest agreement in motion artifact ranking when compared to the readers, and the highest linear correlation to the reader scores. The validated motion artifact metrics may be useful for developing and evaluating methods to reduce motion in Coronary Computed Tomography Angiography (CCTA) images
- âŠ