Early changes in diaphragmatic function evaluated using ultrasound in cardiac surgery patients: a cohort study.
Little is known about the evolution of diaphragmatic function in the early post-cardiac surgery period. The main purpose of this work is to describe its evolution using ultrasound measurements of muscular excursion and thickening fraction (TF). Single-center prospective study of 79 consecutive uncomplicated elective cardiac surgery patients, using motion-mode during quiet unassisted breathing. Excursion and TF were measured sequentially for each patient [pre-operative (D1), 1 day (D2) and 5 days (D3) after surgery]. Pre-operative median for right and left hemidiaphragmatic excursions were 1.8 (IQR 1.6 to 2.1) cm and 1.7 (1.4 to 2.0) cm, respectively. Pre-operative median right and left thickening fractions were 28 (19 to 36) % and 33 (22 to 51) %, respectively. At D2, there was a reduction in both excursion (right: 1.5 (1.1 to 1.8) cm, p < 0.001, left: 1.5 (1.1 to 1.8), p = 0.003) and thickening fractions (right: 20 (15 to 34) %, p = 0.021, left: 24 (17 to 39) %, p = 0.002), followed by a return to pre-operative values at D3. A positive moderate correlation was found between excursion and thickening fraction (Spearman's rho 0.518 for right and 0.548 for left hemidiaphragm, p < 0.001). Interobserver reliability yielded a bias below 0.1 cm with limits of agreement (LOA) of ± 0.3 cm for excursion and - 2% with LOA of ± 21% for thickening fractions. After cardiac surgery, the evolution of diaphragmatic function is characterized by a transient impairment followed by a quick recovery. Although ultrasound diaphragmatic excursion and thickening fraction are correlated, excursion seems to be a more feasible and reproducible method in this population
Method and apparatus for non-invasive evaluation of diaphragmatic function
A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical
Robotics have focused on rigid and non deformable anatomical structures.
Nowadays, special attention is paid to soft tissues, raising complex issues due
to their mobility and deformation. Mini-invasive digestive surgery was probably
one of the first fields where soft tissues were handled through the development
of simulators, tracking of anatomical structures and specific assistance
robots. However, other clinical domains, for instance urology, are concerned.
Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU,
radiofrequency, or cryoablation), increasingly early detection of cancer, and
use of interventional and diagnostic imaging modalities, recently opened new
challenges to the urologist and scientists involved in CAMI. This resulted in
the last five years in a very significant increase of research and developments
of computer-aided urology systems. In this paper, we propose a description of
the main problems related to computer-aided diagnostic and therapy of soft
tissues and give a survey of the different types of assistance offered to the
urologist: robotization, image fusion, surgical navigation. Both research
projects and operational industrial systems are discussed
Respiratory muscle ultrasonography evaluation and its clinical application in stroke patients: A review
BackgroundRespiratory muscle ultrasound is a widely available, highly feasible technique that can be used to study the contribution of the individual respiratory muscles related to respiratory dysfunction. Stroke disrupts multiple functions, and the respiratory function is often significantly decreased in stroke patients.MethodA search of the MEDLINE, Web of Science, and PubMed databases was conducted. We identified studies measuring respiratory muscles in healthy and patients by ultrasonography. Two reviewers independently extracted and documented data regarding to the criteria. Data were extracted including participant demographics, ultrasonography evaluation protocol, subject population, reference values, etc.ResultA total of 1954 participants from 39 studies were included. Among them, there were 1,135 participants from 19 studies on diaphragm, 259 participants from 6 studies on extra-diaphragmatic inspiratory muscles, and 560 participants from 14 studies on abdominal expiratory muscles. The ultrasonic evaluation of diaphragm and abdominal expiratory muscle thickness had a relatively typically approach, while, extra-diaphragmatic inspiratory muscles were mainly used in ICU that lack of a consistent paradigm.ConclusionDiaphragm and expiratory muscle ultrasound has been widely used in the assessment of respiratory muscle function. On the contrary, there is not enough evidence to assess extra-diaphragmatic inspiratory muscles by ultrasound. In addition, the thickness of the diaphragm on the hemiplegic side was lower than that on the non-hemiplegic side in stroke patients. For internal oblique muscle (IO), rectus abdominis muscle (RA), transversus abdominis muscle (TrA), and external oblique muscle (EO), most studies showed that the thickness on the hemiplegic side was lower than that on the non-hemiplegic side.Clinical Trial Registration: The protocol of this review was registered in the PROSPERO database (CRD42022352901)
European Respiratory Society Statement on Thoracic Ultrasound
Thoracic ultrasound is increasingly considered to be an essential tool for the pulmonologist. It is used in diverse clinical scenarios, including as an adjunct to clinical decision making for diagnosis, a real-time guide to procedures, and a predictor or measurement of treatment response. The aim of this European Respiratory Society task force was to produce a statement on thoracic ultrasound for pulmonologists using thoracic ultrasound within the field of respiratory medicine. The multidisciplinary panel performed a review of the literature, addressing major areas of thoracic ultrasound practice and application. The selected major areas include equipment and technique, assessment of the chest wall, parietal pleura, pleural effusion, pneumothorax, interstitial syndrome, lung consolidation, diaphragm assessment, intervention guidance, training, and the patient perspective. Despite the growing evidence supporting the use of thoracic ultrasound, the published literature still contains a paucity of data in some important fields. Key research questions for each of the major areas were identified, which serve to facilitate future multi-centre collaborations and research to further consolidate an evidence-based use of thoracic ultrasound, for the benefit of the many patients being exposed to clinicians using thoracic ultrasound
Diaphragm ultrasound as a better predictor of successful extubation from mechanical ventilation than rapid shallow breathing index
Background In 3%–19% of patients, reintubation is needed 48–72 hours following extubation, which increases intensive care unit (ICU) morbidity, mortality, and expenses. Extubation failure is frequently caused by diaphragm dysfunction. Ultrasonography can be used to determine the mobility and thickness of the diaphragm. This study looked at the role of diaphragm excursion (DE) and thickening fraction in predicting successful extubation from mechanical ventilation. Methods Thirty-one patients were extubated with the advice of an ICU consultant using the ICU weaning regimen and diaphragm ultrasonography was performed. Ultrasound DE and thickening fraction were measured three times: at the commencement of the T-piece experiment, at 10 minutes, and immediately before extubation. All patients' parameters were monitored for 48 hours after extubation. Rapid shallow breathing index (RSBI) was also measured at the same time. Results Successful extubation was significantly correlated with DE (P<0.001). Receiver curve analysis for DE to predict successful extubation revealed good properties (area under the curve [AUC], 0.83; P<0.001); sensitivity, 77.8%; specificity, 84.6%; positive predictive value (PPV), 84.6 %; negative predictive value (NPV), 73.3% while cut-off value, 11.43 mm. Diaphragm thickening fraction (DTF) also revealed moderate curve properties (AUC, 0.69; P=0.06); sensitivity, 61.1%; specificity, 84.6%; PPV, 87.5%; NPV, 61.1% with cut-off value 22.33% although former one was slightly better. RSBI could not reach good receiver operating characteristic value at cut-off points 100 breaths/min/L (AUC, 0.58; P=0.47); sensitivity, 66.7%; specificity, 53.8%; PPV, 66.7%; NPV, 53.8%). Conclusions To decrease the rate of reintubation, DE and DTF are better indicators of successful extubation. DE outperforms DTF
Updated Perspectives on the Role of Biomechanics in COPD: Considerations for the Clinician
Patients with chronic obstructive pulmonary disease (COPD) demonstrate extra-pulmonary functional decline such as an increased prevalence of falls. Biomechanics offers insight into functional decline by examining mechanics of abnormal movement patterns. This review discusses biomechanics of functional outcomes, muscle mechanics, and breathing mechanics in patients with COPD as well as future directions and clinical perspectives. Patients with COPD demonstrate changes in their postural sway during quiet standing compared to controls, and these deficits are exacerbated when sensory information (eg, eyes closed) is manipulated. If standing balance is disrupted with a perturbation, patients with COPD are slower to return to baseline and their muscle activity is differential from controls. When walking, patients with COPD appear to adopt a gait pattern that may increase stability (eg, shorter and wider steps, decreased gait speed) in addition to altered gait variability. Biomechanical muscle mechanics (ie, tension, extensibility, elasticity, and irritability) alterations with COPD are not well documented, with relatively few articles investigating these properties. On the other hand, dyssynchronous motion of the abdomen and rib cage while breathing is well documented in patients with COPD. Newer biomechanical technologies have allowed for estimation of regional, compartmental, lung volumes during activity such as exercise, as well as respiratory muscle activation during breathing. Future directions of biomechanical analyses in COPD are trending toward wearable sensors, big data, and cloud computing. Each of these offers unique opportunities as well as challenges. Advanced analytics of sensor data can offer insight into the health of a system by quantifying complexity or fluctuations in patterns of movement, as healthy systems demonstrate flexibility and are thus adaptable to changing conditions. Biomechanics may offer clinical utility in prediction of 30-day readmissions, identifying disease severity, and patient monitoring. Biomechanics is complementary to other assessments, capturing what patients do, as well as their capability
- …