6,492 research outputs found

    Fast tomographic inspection of cylindrical objects

    Get PDF
    This paper presents a method for improved analysis of objects with an axial symmetry using X-ray Computed Tomography (CT). Cylindrical coordinates about an axis fixed to the object form the most natural base to check certain characteristics of objects that contain such symmetry, as often occurs with industrial parts. The sampling grid corresponds with the object, allowing for down-sampling hence reducing the reconstruction time. This is necessary for in-line applications and fast quality inspection. With algebraic reconstruction it permits the use of a pre-computed initial volume perfectly suited to fit a series of scans where same-type objects can have different positions and orientations, as often encountered in an industrial setting. Weighted back-projection can also be included when some regions are more likely subject to change, to improve stability. Building on a Cartesian grid reconstruction code, the feasibility of reusing the existing ray-tracers is checked against other researches in the same field.Comment: 13 pages, 13 figures. submitted to Journal Of Nondestructive Evaluation (https://www.springer.com/journal/10921

    Confocal Laser Induced Fluorescence with Comparable Spatial Localization to the Conventional Method

    Full text link
    We present measurements of ion velocity distributions obtained by laser induced fluorescence (LIF) using a single viewport in an argon plasma. A patent pending design, which we refer to as the confocal fluorescence telescope, combines large objective lenses with a large central obscuration and a spatial filter to achieve high spatial localization along the laser injection direction. Models of the injection and collection optics of the two assemblies are used to provide a theoretical estimate of the spatial localization of the confocal arrangement, which is taken to be the full width at half maximum of the spatial optical response. The new design achieves approximately 1.4 mm localization at a focal length of 148.7 mm, improving on previously published designs by an order of magnitude and approaching the localization achieved by the conventional method. The confocal method, however, does so without requiring a pair of separated, perpendicular optical paths. The confocal technique therefore eases the two window access requirement of the conventional method, extending the application of LIF to experiments where conventional LIF measurements have been impossible or difficult, or where multiple viewports are scarce

    Iterative CT reconstruction from few projections for the nondestructive post irradiation examination of nuclear fuel assemblies

    Get PDF
    The core components (e.g. fuel assemblies, spacer grids, control rods) of the nuclear reactors encounter harsh environment due to high temperature, physical stress, and a tremendous level of radiation. The integrity of these elements is crucial for safe operation of the nuclear power plants. The Post Irradiation Examination (PIE) can reveal information about the integrity of the elements during normal operations and off‐normal events. Computed tomography (CT) is a tool for evaluating the structural integrity of elements non-destructively. CT requires many projections to be acquired from different view angles after which a mathematical algorithm is adopted for reconstruction. Obtaining many projections is laborious and expensive in nuclear industries. Reconstructions from a small number of projections are explored to achieve faster and cost-efficient PIE. Classical reconstruction algorithms (e.g. filtered back projection) cannot offer stable reconstructions from few projections and create severe streaking artifacts. In this thesis, conventional algorithms are reviewed, and new algorithms are developed for reconstructions of the nuclear fuel assemblies using few projections. CT reconstruction from few projections falls into two categories: the sparse-view CT and the limited-angle CT or tomosynthesis. Iterative reconstruction algorithms are developed for both cases in the field of compressed sensing (CS). The performance of the algorithms is assessed using simulated projections and validated through real projections. The thesis also describes the systematic strategy towards establishing the conditions of reconstructions and finds the optimal imaging parameters for reconstructions of the fuel assemblies from few projections. --Abstract, page iii

    A Learning-based Method for Online Adjustment of C-arm Cone-Beam CT Source Trajectories for Artifact Avoidance

    Full text link
    During spinal fusion surgery, screws are placed close to critical nerves suggesting the need for highly accurate screw placement. Verifying screw placement on high-quality tomographic imaging is essential. C-arm Cone-beam CT (CBCT) provides intraoperative 3D tomographic imaging which would allow for immediate verification and, if needed, revision. However, the reconstruction quality attainable with commercial CBCT devices is insufficient, predominantly due to severe metal artifacts in the presence of pedicle screws. These artifacts arise from a mismatch between the true physics of image formation and an idealized model thereof assumed during reconstruction. Prospectively acquiring views onto anatomy that are least affected by this mismatch can, therefore, improve reconstruction quality. We propose to adjust the C-arm CBCT source trajectory during the scan to optimize reconstruction quality with respect to a certain task, i.e. verification of screw placement. Adjustments are performed on-the-fly using a convolutional neural network that regresses a quality index for possible next views given the current x-ray image. Adjusting the CBCT trajectory to acquire the recommended views results in non-circular source orbits that avoid poor images, and thus, data inconsistencies. We demonstrate that convolutional neural networks trained on realistically simulated data are capable of predicting quality metrics that enable scene-specific adjustments of the CBCT source trajectory. Using both realistically simulated data and real CBCT acquisitions of a semi-anthropomorphic phantom, we show that tomographic reconstructions of the resulting scene-specific CBCT acquisitions exhibit improved image quality particularly in terms of metal artifacts. Since the optimization objective is implicitly encoded in a neural network, the proposed approach overcomes the need for 3D information at run-time.Comment: 12 page

    High resolution laboratory x-ray tomography for biomedical research : From design to application

    Get PDF
    Laboratory x-ray micro- and nano-tomography are emerging techniques in biomedical research. Through the use of phase-contrast, sufficient contrast can be achieved in soft tissue to support medical studies. With ongoing developments of x-ray sources and detectors, biomedical studies can increasingly be performed at the laboratory and do not necessary require synchrotron radiation. Particularly nano-focus x-ray sources offer new possibilities for the study of soft tissue. However, with increasing resolution, the complexity and stability requirements on laboratory systems advance as well. This thesis describes the design and implementation of two systems: a micro- CT and a nano-CT, which are used for biomedical imaging.To increase the resolution of the micro-CT, super-resolution imaging is adopted and evaluated for x-ray ima- ging, grating-based imaging and computed tomography utilising electromagnetic stepping of the x-ray source to acquire shifted low-resolution images to estimate a high-resolution image. The experiments have shown that super-resolution can significantly improve the resolution in 2D and 3D imaging, but also that upscaling during the reconstruction can be a viable approach in tomography, which does not require additional images.Element-specific information can be obtained by using photon counting detectors with energy-discriminating thresholds. By performing a material decomposition, a dataset can be split into multiple different materials. Tissue contains a variety of elements with absorption edges in the range of 4 – 11 keV, which can be identified by placing energy thresholds just below and above these edges, as we have demonstrated using human atherosclerotic plaques.An evaluation of radiopaque dyes as alternative contrast agent to identify vessels in lung tissue was performed using phase contrast micro-tomography. We showed that the dye solutions have a sufficiently low density to not cause any artefacts while still being able to separate them from the tissue and distinguish them from each other.Finally, the design and implementation of the nano-CT system is discussed. The system performance is assessed in 2D and 3D, achieving sub-micron resolution and satisfactory tissue contrast through phase contrast. Applica- tion examples are presented using lung tissue, a mouse heart, and freeze dried leaves

    A pilot study for the digital replacement of a distorted dentition acquired by Cone Beam Computed Tomography (CBCT)

    Get PDF
    Abstract Introduction: Cone beam CT (CBCT) is becoming a routine imaging modality designed for the maxillofacial region. Imaging patients with intra-oral metallic objects cause streak artefacts. Artefacts impair any virtual model by obliterating the teeth. This is a major obstacle for occlusal registration and the fabrication of orthognathic wafers to guide the surgical correction of dentofacial deformities. Aims and Objectives: To develop a method of replacing the inaccurate CBCT images of the dentition with an accurate representation and test the feasibility of the technique in the clinical environment. Materials and Method: Impressions of the teeth are acquired and acrylic baseplates constructed on dental casts incorporating radiopaque registration markers. The appliances are fitted and a preoperative CBCT is performed. Impressions are taken of the dentition with the devices in situ and subsequent dental models produced. The models are scanned to produce a virtual model. Both images of the patient and the model are imported into a virtual reality software program and aligned on the virtual markers. This allows the alignment of the dentition without relying on the teeth for superimposition. The occlusal surfaces of the dentition can be replaced with the occlusal image of the model. Results: The absolute mean distance of the mesh between the markers in the skulls was in the region of 0.09mm ± 0.03mm; the replacement dentition had an absolute mean distance of about 0.24mm ± 0.09mm. In patients the absolute mean distance between markers increased to 0.14mm ± 0.03mm. It was not possible to establish the discrepancies in the patient’s dentition, since the original image of the dentition is inherently inaccurate. Conclusion: It is possible to replace the CBCT virtual dentition of cadaveric skulls with an accurate representation to create a composite skull. The feasibility study was successful in the clinical arena. This could be a significant advancement in the accuracy of surgical prediction planning, with the ultimate goal of fabrication of a physical orthognathic wafer using reverse engineering
    • 

    corecore